background image

© 2001 DESA International

598-1038-02

Dual Brite

Motion Sensor
Light Control for
Canadian Tire

Model SL-5597

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Brite™ Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

This package includes:

2 Wire

Connectors

Gasket

Cover

Plate

Sensor

6 Screws

(3 sizes included)

Light Control

Requirements

The Light Control requires 120-volts AC.

If you want to use Manual Override, the control
must be wired through a switch.

Some codes require installation by a qualified
electrician.

This product is intended for use with a junction box
marked for use in wet locations.

Mounting Strap

Mounting Bolt

2 Lamps

(installed)

OPERATION

* resets to Auto Mode at dawn.

TEST

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to

Dawn

DUAL BRITE™

Put ON-TIME switch
on the sensor bottom
to TEST and the Dual
Brite™ switch OFF.

MANUAL MODE

ON-TIME

TEST 1 5 20

... back on.

AUTO

1 Second OFF

then...

Put the ON-TIME switch in the 1, 5 or
20 minute position.

Dual Brite™ TIMER

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light
turns on full bright for the ON-TIME (1,5 or 20 minutes)
then returns to dim mode.

Move ON-TIME Switch

to 1, 5 or 20 minutes

Mode Switching Summary

Flip light switch

off for one second

then back on*

MANUAL MODE

AUTO

TEST

Note: When first turned on wait about 1

1

/

2

 minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.

Test

5 Sec

x

x

Auto

1, 5, 20 min.

x

Manual Until Dawn*

x

Mode:    On-Time:

Works: Day

Night

Lamp

Holders

Rubber Plug

Plastic Hanger

Summary of Contents for Dual Brite SL-5597

Page 1: ...TEST and the Dual Brite switch OFF MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 20 minute position Dual Brite TIMER Light comes on half bright for selected time after dusk Off 3 hr 6 hr until dawn If motion is sensed the light turns on full bright for the ON TIME 1 5 or 20 minutes then returns to dim mode Move ON TIME Switch to 1 5 or 20 minut...

Page 2: ...ack into the ball joint Tighten the clamp screw when done Mounting Strap Mounting Bolt White to White Black to Black Gasket Junction box ground wire to green ground screw on fixture Rubber Plug WIRE THE LIGHT CONTROL Turn power off at the fuse or circuit breaker Remove the existing light fixture Bulb installation NOTE When re lamping turn power off and let the fixture cool To remove lamp shade loo...

Page 3: ...ytighteningtheclampscrew Do not overtighten the screw Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 20 minutes Set the DUAL BRITE switch to the amount of time after dusk you want the lights on at low level Off 3 6 Hrs Dusk to Dawn Clamp Screw Ball Joint Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Coverage Maximum Range 240 Maximum Coverage ...

Page 4: ...s positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects 2 Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective surface Reposition sensor Reduce Range 3 LightControlisinManualMode SwitchtoAuto 1 Heat or light from the lamps may be turnin...

Page 5: ... luego Mueva el interruptor de tiempo ON TIME a 1 5 ó 20 minutos Apague el interruptor por un segundo y préndalo de nuevo ON TIME TEST 1 5 20 Ponga el interruptor de tiempo ON TIME en la posición de 1 5 ó 20 minutos Para AUTOMATICO Resumen de las modalidades del interruptor Ponga el interruptor detiempo ON TIME al fondo del detector en la posición de prueba TEST yDual Brite a apagado OFF Para PRUE...

Page 6: ...ntaje Empuje el tapón de caucho firmemente hasta que encaje Sinoseusóunacajadeempalmeenunlugarhúmedo calafateelasuperficiedemontajedelaplacadelapared con un sellador de silicona contra la intemperie Instalación de bombilla Sieldetectorsesaledelauniónesférica aflojeeltornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Cable de a tie...

Page 7: ...llo de la grampa No ajuste demasiado el tornillo Fije el período de TIEMPO que la luz debe quedarse prendida cuando detecta movimiento Se lo puede calibrar de 1 5 ó 20 minutos Para una iluminación ornamental de baja intensidad pongaelinterruptordeDualBrite en la posición de 3 6 ó del Dusk to Dawn atardecer al amanecer Tornillo de la Grampa Unión Esférica Apunte el detec tor hacia abajo para una co...

Page 8: ...erficie con pintura brillante y que refleja el calor Reposicione el detector 3 El control de luz está en la Modo Manual Cámbiela a Automática 1 El calor o la luz de las lámparas pueden estar prendiendo y apagando el Control de Luz Reposicione las lámparas lejos del detector 2 Elcalorquesereflejadeotrosobjetos pueden estar afectando al detector Reposicione el detector 3 El Control de Luz está en fa...

Page 9: ... alimentation pendant une minute puis la rétablir Après le temps d étalonnage la commande reviendra au mode AUTO Placer l interrupteur de temps en dircuit ON TIME à la base du capteur à TEST et l interrupteur Dual Brite à OFF ON TIME Amener l interrupteur de temps en circuit ON TIME à la position correspondant à 1 5 ou 20 minutes TEST 1 5 20 TEST 1 5 20 ON TIME Off 3 6 Dusk to Dawn DUAL BRITE Minu...

Page 10: ... intérieur de la boîte de jonction Aligner la vis de montage sur le centre du trou de la bride de mon tage Fixer l appareil à la bride de montage Poussez le bouchon de caoutchouc fermement en place Si une boîte de jonction pour endroit mouillé n a pas été utilisée calfeutrer la surface de montage de la plaque murale avec un scellant silicone d extérieur Abat jour Vis de blocage Installation de l a...

Page 11: ... Pour une couverture accrue utiliserl amplificationdeportée Range Boost Fixerlatêtedudétecteurenposi tionenserrantlavisedeblocage Éviter de trop serrer la vis Placer l interrupteur ON TIME à 1 5 ou 20 minutes Réglerl interrupteurDualBrite autempsd allumage désiré àfaibleintensité aprèslecrépuscule 3h 6h crépuscule aurore Mouvement Le détecteur est moins sensible au mouvement dans sa direction Port...

Page 12: ...jecteur se trouve trop près du détecteur de la commande d éclairage ou est pointé vers des objets tout près dont la chaleur déclenche le détecteur Éloigner le projecteur du détecteur ou des objets avoisinants 2 Ledétecteurdelacommanded éclairage pointe vers une source de chaleur comme un évent d aération un évent de sécheuse ou une surface peinte de couleur vive réfléchissant la chaleur Réorienter...

Reviews: