Disposal Responsibilities:

 

The equipment you purchased may contain hazardous substances that 

could impact the environment. Per regulations on electronic devices in 

the European Community, you must use the appropriate disposal  

systems to avoid exposure of these substances to the environment. 

The disposal systems will reuse or recycle hazardous materials from 

your equipment responsibly.

The crossed-out wheeled bin symbol  invites you  

to use those systems.

If you need more information on the collection, reuse and recycling  

systems, please contact your local or regional waste administration.  

You can also contact us for more information on the environmental 

performance of our products.

Changes or modifications to the product not expressly approved by the manu-
facturer could void the user’s authority to operate the equipment.

This product has been tested and found to comply with the limits of  
a Class A digital device pursuant to Part 15 of the FCC rules.  These limits 
are designed to provide reasonable protection against harmful interference 
when the product is operating in a commercial  
environment.  The product generates, uses, and can radiate radio frequency 
energy and if not installed and used in accordance with the user’s manual 
may cause harmful interference to radio communications.  Operation of the 
product in a residential area is likely to caused interference in which case 
the user will be required to correct the interference.

Supplied Equipment:  

• 

1 ea. Centrifuge

• 

1 ea. Universal AC power adapter with 4 mains cables

• 

1 ea. Standard Tube rotor (1.5mL & 2.0mL tubes) (12,500 rpm)

• 

1 ea. Strip tube rotor (8 place 0.2ml Strip Tubes or 32 individual 0.2ml 
tubes) (12,500 rpm)

• 

12 ea. 0.2mL tube adapters (for use in the standard rotor only)

• 

12 ea. 0.5mL tube adapters (for use in the standard rotor only)

Operating Conditions:

 

Maximum speed: 500rpm - 12,500 rpm

 

Maximum RCF: 9,800 RCF

 

Electrical: 100 – 240VAC, 50/60Hz

 

Ambient temperature:  2°C to 40°C

 

Relative humidity:  ≤80% noncondensing

Power Requirements:
 

12VDC 8.33A

Storage Conditions:

 

Storage temperature:  20°C - 55°C

 

Relative humidity:  ≤90% noncondensing

Technical Data

EC Declaration of Conformity

Manufacturer:  Heathrow Scientific®
Address: 620 Lakeview Parkway • Vernon Hills, IL 60061 USA
European Contact:  Emergo Europe
Molenstraat 15, 2513 BH, The Hague, The Netherlands
This unit has been constructed and conforms to the following:
Safety Standards:  
 EN61010-1:2010
 EN61010-2-020:2006
 IEC61010-1
 IEC61010-2-020
 

UL Std. 61010A-1, 61010A-02-20

 

CAN/CSA C22.2 No. 61010-1-04 (R2009)

 

CAN/CSA C22.2 No. 61010-2-020-09

 

2006/95/EC (Low Voltage Directive)

EMC Standards:  
 EN61326-1:2006
2002/96/EC (WEEE)
2002/95/EC (RoHS)
 
Signed:  
 

Jamie Devin, Managing Director 

Note:

Note:

Positive Polarity

This mark is the confirmation that the unit conforms to  
the EU guidelines and has been tested according to the  
following EU Declaration of Conformity.

Conforms to UL Std. 61010-1.  
Certified to CAN/CSA C22.2 No. 1010.2.020-94.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for Gusto

Page 1: ...g x All rights reserved Printed in China Tous droits réservés Imprimé en Chine Todos los derechos reservados Impreso en Chine Alle Rechte vorbehalten Gedruckt in China Instruction Manual 26 015 10050 51 483 Heathrow Scientific LLC High Speed Mini Centrifuge www com information itm com 1 800 561 8187 ...

Page 2: ... manual contains important information safeguards and operating instructions 17 Follow all precautions from the Material Safety Data Sheet MSDS for any reagent you use with this instrument 18 Do not use solvent or flammable liquids near this or other electrical equipment 19 Do not centrifuge flammable explosive or corrosive materials 20 Do not operate in a hazardous or flammable environment 21 Do ...

Page 3: ... which case the user will be required to correct the interference Supplied Equipment 1 ea Centrifuge 1 ea Universal AC power adapter with 4 mains cables 1 ea Standard Tube rotor 1 5mL 2 0mL tubes 12 500 rpm 1 ea Strip tube rotor 8 place 0 2ml Strip Tubes or 32 individual 0 2ml tubes 12 500 rpm 12 ea 0 2mL tube adapters for use in the standard rotor only 12 ea 0 5mL tube adapters for use in the sta...

Page 4: ...flow An overheating situation could occur Verify that the power switch in the back of the unit is in the OFF position Plug the DC cord into the rear of the unit and the AC cord an approved outlet Display Display Status LID OPEN Lid is open READY Unit ready to centrifuge SPIN UP Cycle is starting and is increasing speed SPINNING Running in Standard mode SPIN DOWN Cycle is slowing down STOPPED Cycle...

Page 5: ...k Spin button rotor should spin up to the set speed 3 The timer will begin counting 4 Once enough time has elapsed for your needs release the Quick Spin button The rotor will spin down stop and the unit will emit a beep when the cycle is complete 5 To open lid press the OPEN button Other Change Between RPM and RCF Prior to a spin cycle press both the Speed Up Down buttons simultaneously The speed ...

Page 6: ...2 Strip 2 Tubes 4 Tubes 6 Tubes 8 Tubes 10 Tubes 12 Tubes Warning Do not attempt to open lid until rotor has completely stopped Avoid severe personal injury or property damage from moving parts Only use rotor compatible with the centrifuge Warning Do not use damaged or cracked rotors Rotor installation and removal To remove rotor With one hand grasp the rotor With the other hand unscrew center kno...

Page 7: ...LIGATION UNDER THIS WARRANTY EXCEED THE PRICE OF THE PRODUCT Heathrow Scientific LLC will not accept any product return that is not appropriately cleaned and decontaminated In the unlikely event of repair or when damage to the unit necessitates return contact Heathrow Scientific LLC and obtain return authorization before sending your product for service Return for Repair Important Transporting haz...