Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Auto

1, 5, 10 min.

x

Manual

Until Dawn*

x

OPERATION

* resets to Auto Mode at dawn.

MANUAL MODE

ON-TIME

10 5 1 TEST

10 5 1 TEST

ON-TIME

TEST

... back on.

AUTO

1 Second OFF

then...

Move ON-TIME Switch to

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

• Some codes require installation by a

qualified electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Model SL-9525

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

Motion Sensor Light
Control

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.

Note: When first turned on wait about 1 

1

/

2

 minutes for

the circuitry to calibrate.

Gasket

4 Screws

(2 sizes included)

2 Flood Lamps

2 Wire

Connectors

This package includes:

Light Control

Sensor

Cover

Plate

Lamp Holders

2 Shells

Light Shield

As an ENERGY STAR

®

 Partner, Heath

®

/Ze-

nith has determined that this product meets
the ENERGY STAR

®

  guidelines for energy

efficiency. This product is ENERGY STAR

®

compliant when used with 120 Watt bulbs.

Manual mode only works at night
because daylight returns the sen-
sor to AUTO.

Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Put the ON-TIME switch in the 1, 5,
or 10 minute position.

Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.

Summary of Contents for SL-9525

Page 1: ...ours LED indicates motion was sensed day or night Motion Sensor Light Control If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate Gasket 4 Screws 2 sizes included 2 Flood Lamps 2 Wire Connectors This package includes ...

Page 2: ...ount Eave Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper opera tion and to avoid the risk of electrical shock Also for proper under eave operation remove the protective backingfromtheLightShieldandstickonasshownbelow Shell Slot 123456789012345678 123456789012345678 123456789012345678 Clamp Screw Lock Nut To avoid water damage and electri...

Page 3: ...oad Up to 300 Watt Maximum In candescent Up to 150 Watt maximum each lamp holder Power Requirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes DESA Specialty Products reserves the right to dis continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold NOTE Sensor has abou...

Page 4: ...2102 9004 ATTN Technical Service Specialty Products If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product TEN YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to prov...

Page 5: ...he Control de luz del detector de movimiento Si se confunde mientras cambia de fases apague la electricidad por un minuto y préndala de nuevo Después del tiempo de calibración el control estará en fase AUTO MATICA Nota Cuando lo prenda por primera vez espere 1 1 2 minutos para que el circuito se claibre Este paquete tiene Empaque 4 tornillos 2 dimensiones 2 Faros 2 conectores de alambre Control de...

Page 6: ... gire la cabeza del detector hacia la derecha por 180 hasta que los controles miren hacia abajo Sieldetectorsesaledelauniónesférica aflojeeltornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Controles Controles CONECTE EL CONTROL DE LUZ Blanco a blanco Negro a negro Empaquetadura Cable de a tierra de la caja de empalme al tornillo...

Page 7: ...idadpuedeaumentar las falsas alarmas Asegure la puntería de la cabeza del detector ajustando el tornillo sujetador No lo apriete demasiado Fije el período de tiempo ON TIME que la luz debe quedarse prendida después de detectar movimiento 1 5 ó 10 minutos ESPECIFICACIONES Alcance Hasta 70 pies 21 m varía de acuerdo a la temperatura que le rodea Angulo de detección Hasta 180 Carga Eléctrica Hasta 30...

Page 8: ...untas en español por teléfono Usted puede también escribir a DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra GARANTÍA LIMITADA A DIAZ AÑOS Esta es una Garantía Limitada que le da a Ud derechos legales específicos Usted puede también tener otros derecho...

Page 9: ...e se trouve l appareil couper l alimentation pendant une minute puis la rétablir Après le temps d étalonnage la commande reviendra au mode AUTO Note Après mise en circuit attendre enfiron 1 1 2 minute pour que l étalonnage du circuit soit complété Cet emballage comprend Garniture de joint 4 vis incluses 2 formats 2 lampes réflecteurs incandescentes 2 serre fils Commande d éclairage Détecteur Plaqu...

Page 10: ...oient tournées vers le bas Commandes Montage mural Montage sous avant toit Pouréviterlerisquedechocélectrique lescommandes du détecteur doivent être tournées vers le bas De plus pour un fonctionnement approprié sous avant toit enlever l endos antiadhésif de l écran de protection et coller celui ci comme indiqué ci dessous Fente dans l enveloppe Vis De Blocage Contre écrou Pour éviter les dommages ...

Page 11: ...120 V CA 60 Hz Modes de fonctionnement Essai automatique et priorité manuelle Délais 1 5 et 10 minutes Portée Réglable DESA Specialty Products se réserve le doit d abandonner tout produit et d en changer les spécifications entouttempsetsanscontracterquelque obligation que ce soit quant à l incorporation de nouvelles caractéristiques aux produits déjà vendus NOTE Lecapteurdoitseréchauffer11 2 minut...

Page 12: ...42102 9004 Lors d un appel au service technique veuillez avoir les renseignements suivants à portée de main numéro du modèle date d achat et endroit de l achat GARANTIE LIMITÉE DE DIX ANS Il s agit d une Garantie limitée qui vous confère des droits juridiques spécifiques Vous pouvez également jouir d autres droits variables d une province à l autre Pendant une période de dix ans à compter de la da...