SPECIFICATIONS

Horizontal Range . . . . Up  to  70  ft.  (21  m);  100  ft. 

(30.5  m)  with  Range  Boost.  
[varies  with  surrounding 
temperature]

Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80° 

Vertical

Electrical Load . . . . . . Up to 200 Watts Maximum In-

candescent  (Up  to  100  Watts 
Maximum each lamp holder.)

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . 1, 5, 20 minutes
D

ual

B

rite

®

 Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn

Replacement lamp . . . T4 100W, G8 halogen bi-pin 120 

VAC

POSSIBLE CAUSE
1.  A lamp is positioned too close to the 

sensor  or  pointed  at  nearby  objects 
that cause heat to trigger the sensor. 

(Reposition  the  lamp  away  from  the 
sensor or nearby objects)

.

2.  Light control is pointed toward a heat 

source like an air vent, dryer vent, or 
brightly-painted heat-reflective surface. 

(Reposition sensor. Reduce Range)

.

3.  Light control is in Manual Mode.

 (Switch 

to Auto)

.

1.  Heat or light from the lamps may be 

turning  the  light  control  on  and  off. 

(Reposition the lamps away from the 
sensor)

.

2.  Heat being reflected from other objects 

may be affecting the sensor. 

(Reposi-

tion sensor)

.

3.  Light control is in the Test mode and 

warming up. 

(Flashing is normal under 

these conditions. Turn Boost off)

.

1.  Sensor  is  detecting  its  own  lights. 

(Reposition lamps to keep area below 
the sensor relatively dark).

SYMPTOM
Lights stay 
on continu-
ously.

Lights flash 
on and off.

Lights flash 
once, then 
stay off in 
Manual Mode.

SYMPTOM
Lights will 
not come 
on.

Lights come 
on in day-
light.

Lights come 
on for no 
apparent 
reason.

Lights turn 
off too late 
in Dusk-
to-Dawn 
setting.

POSSIBLE CAUSE
1.  Light switch is turned off.
2.  Light is loose or burned out.
3.  Fuse is blown or circuit breaker is turned 

off.

4.  Daylight turnoff is in effect 

(recheck after 

dark)

5.  Incorrect circuit wiring, if this is a new 

installation.

6.  Re-aim the sensor to cover desired area.
1.  Light control may be installed in a rela-

tively dark location.

2.  Light control is in Test. 

(Set control switch 

to an ON-TIME position)

.

1.  Light  control  may  be  sensing  small 

animals  or  automobile  traffic 

(re-aim 

sensor)

.

2.  Range is set too high. 

(Reduce Range 

setting)

.

3.  D

ual

B

rite

®

 Timer is on.

1.  Sensor is in a relatively dark location. 

(Relocate sensor, or use 3 hr or 6 hr 
setting)

.

TROUBLESHOOTING GUIDE

1 YEAR LIMITED WARRANTY:

Should this product fail to perform satisfactorily due to a defect or poor workmanship within one year of date of 
purchase, return it to the place of purchase and it will be replaced, free of charge. Incidental or consequential 
damages are excluded from this warranty. Light bulbs are not covered.

Manufactured for Grainger International, Inc.
Lake Forest, IL 60045

Summary of Contents for DualBrite Motion Sensor Light Control 2LBL3

Page 1: ...h Some codes require installation by a qualified electrician This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations Mode On Time Works Day Night Test 5 Seconds x x Auto 1 5 or 20 Min x Manual To Dawn x Accent 3 6 Hr to Dawn x AUTO MANUAL MODE Features DualZone Technology Turns on lighting when motion is detected Automatically turns lightin...

Page 2: ...tinue to work as described in this manual If motion is sensed the light turns on full bright for the ON TIME 1 5 or 20 minutes then returns to dim mode INSTALLATION For easy installation select an existing light operated by a wall switch for replacement For best performance mount the fixture about 8 ft 2 4 m above the ground NOTE If fixture is mounted higher than 8 ft 2 4 m aiming the sensor down ...

Page 3: ...reinstall lamp shade place shade on fixture and align notches on shade with tabs on fixture Turn clockwise Tighten set screw firmly Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180 from the factory setting Adjust lamp shades by loosening the set screws several turns turn shades counterclockwise and remove Reinstall the shades in the desired positi...

Page 4: ... detect ed Movethesensorheadup down or sideways to change the coverage area Keep the sensor at least 2 51 mm away from the lamps AdjusttheRANGEasneeded RANGE set too high may increase false triggering Secure the sensor head by tightening the clamp screw Donotovertightenthe screw Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 20 minutes Set the DualBrite switc...

Page 5: ...ff 1 Sensor is detecting its own lights Reposition lamps to keep area below the sensor relatively dark SYMPTOM Lights stay on continu ously Lights flash on and off Lights flash once then stay off in Manual Mode SYMPTOM Lights will not come on Lights come on in day light Lights come on for no apparent reason Lights turn off too late in Dusk to Dawn setting POSSIBLE CAUSE 1 Light switch is turned of...

Page 6: ...aibre Requisitos El control de luz requiere 120 VCA Para usar el Sobrecontrol Manual conecte el control con un interruptor Algunos códigos requieren instalación por un electricista calificado Se recomienda usar este producto con el empaque provisto y con una caja de empalme marcada para uso en lugares húmedos Para AUTOMATICO Para MODO MANUAL Características Tecnología DualZone Prende la luz cuando...

Page 7: ...ión Las funciones que detectan movimiento continuarán funcionando como se descri ben en este manual Si detecta movimiento la luz se prendecontodosuresplandorporeltiempodeduración o de ON TIME 1 5 ó 20 minutos y luego regresa a media luz INSTALACION Para una fácil instalación escoja una luz con un interruptor de pared Para un mejor funcionamiento instale el aparato a casi 2 4 m del suelo NOTA Si el...

Page 8: ...antalla de la lámpara afloje el tornillo prisionerodando2giroscompletosconunpequeño destornillador de cabeza plana Gire la pantalla hacia la izquierda y quítela Para quitar la bombilla hálela derecho hacia afuera del aparato Para cambiar la bombilla empuje los conectado res de la bombilla en el enchufe de la lámpara Asegúrese que la bombilla esté correctamente asentada Para reinstalar la pantalla ...

Page 9: ...el día pueden hacer que el detector se apague No apunte otras luces hacia el detector MAX MIN RANGE ON TIME DUAL BRITE TEST 1 5 20 MINUTES OFF 3 6 DUSK TO DAWN HOUR B O O S T PRUEBA Y AJUSTE Prenda el cortacircuitos y el interruptor de luz NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo prenda por primera vez espere 1 1 2 minutos ...

Page 10: ...se enciende La luz se prende durante el día La luz se prende sin ninguna razón aparente La luz se apaga muy tarde en la calibración del Anochecer al Amanecer POSIBLE CAUSA 1 El interruptor de luz está apagado 2 El faro está flojo o fundido 3 Elfusibleestáquemadooelcortacircuitos está apagado 4 La desconexión de luz del día está en efecto Compruébelo al anochecer 5 Alambrado incorrectamente si ésta...

Page 11: ...e Caoutchouc Garniture de joint 6 vis incluses 3 formats Bride de montage Vis de montage 2 serre fils AUTOMATIQUE En fonction Mode Temps en circuit jour nuit Essai 5 secondes x x Auto 1 5 ou 20 min x Manuel au choix amanecer x Accentuation 3 6 h jusqu à l aurore x 598 1325 00 F LPG 5597 HEA 009 Imprimé en Chine 09 07 Mode d emploi et guide des pièces 2LBL3 2LBL4 Veuillez lire et conserver ces dire...

Page 12: ...té INSTALLATION Pourfaciliterl installation choisirunappareild éclairage devant être remplacé et qui est déjà commandé par un interrupteur Pourassurerunrendementoptimum monterleluminaire à environ 2 4 m au dessus du sol NOTE Lorsque le luminaire est installé à une hauteur supérieure à 8 pi 2 4 m le fait de diriger le détecteur vers le bas réduit la portée de la couverture AVERTISSEMENT Ne pas perm...

Page 13: ... appareil refroidisse Pour enlever l abat jour desserrer la vis de blocage sur 2 tours complets avec un petit tournevis à tête plate Tourner l abat jour dans le sens antihoraire et l enlever Pourretirerl ampoule tirercelle cidirectementhors du luminaire Pourremplacerl ampoule insérerlesbrochesdans la douille de la lampe S assurer que l ampoule est bien assise Pour replacer l abat jour placer celui...

Page 14: ...ositif d arrêt Ne pas pointer d autres appareils d éclairage vers le détecteur MAX MIN RANGE ON TIME DUAL BRITE TEST 1 5 20 MINUTES OFF 3 6 DUSK TO DAWN HOUR B O O S T ESSAIS ET RÉGLAGES Mettre en circuit le disjoncteur et l interrupteur d éclairage NOTE Lecapteurdoitseréchauffer1 1 2 minuteavant de pouvoir détecter le mouvement Lorsque l appareil est mis en circuit attendre 1 1 2 minute Placez le...

Page 15: ...ns raison apparente L éclairage s al lume trop tard sous le réglage crépus cule aube CAUSE POSSIBLE 1 L interrupteurd éclairageestenposition hors circuit 2 Les projecteurs sont brûles ou desserrés 3 Le fusible du circuit a sauté ou le dis joncteur est en position hors circuit 4 La fonction de mise hors circuit à la lumière du jour est engagée Revérifier quand il fait nuit 5 Mauvais câblage s il s ...

Page 16: ..._______________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ___________________________ ...

Reviews: