To see operational and troubleshooting information and videos,
3
go to www.hzsupport.com
208814-01
WIRING
WARNING: Turn power off at circuit breaker or fuse.
Place tape over circuit breaker switch and verify power is
off at the fixture.
1. Remove the existing light fixture.
2. Install the mounting bracket with the stamped word “FRONT”
facing away from the junction box (see Figure 1). Use the mount-
ing bracket screws that best fit the junction box.
3. Attach the junction box ground wire to the ground wire attached
to the mounting bracket using one of the wire connectors (see
Figure 2).
4. Twist the junction box wires and fixture wires together as shown.
Secure with wire connectors (see Figure 2).
• White to White
• Black to Black
FINAL ASSEMBLY
1. Double check that all wiring connections are securely connected.
2. Align the mounting bolt on the back or the fixture with the
center hole in the mounting bracket.
Note:
The mounting bolt is
designed to stay in the light fixture.
3. Tighten the mounting bolt securely being careful not to overtighten
(see Figure 3).
IMPORTANT:
• If wall mounted, make sure the fixture is mounted with the
sensor below the lamp heads.
• If eave mounted, mount the fixture with sensor facing away from
the house wall.
4. Push the rubber plug firmly into the mounting bolt hole on the
light fixture (see Figure 3).
5. Caulk around mounting plate and mounting surface with silicone
weather sealant (see Figure 4).
TESTING AND ADJUSTMENTS
Figure 1
Figure 2
Figure 3
Figure 4
FR
ON
T
FR
ON
T
FR
O
N
T
CAUTION: To avoid water damage and risk of electrical
shock, motion sensor controls must be facing the ground
when installation is complete.
1. Turn on the circuit breaker and light switch.
Note:
The motion sensor has a 1 minute warm up period before
it will detect motion. When first turned on wait 1 minute.
FRON