2.WIRING METHODS FOR SINGLE-SPEED FAN CONNECTION    2.

单速风扇接线方法

 

 

NOTE:

 Heatcraft Wuxi supplies motor fan(s) only. All wiring & associated components are to be supplied 

and fitted on final installation by customer.  

注意:西克无锡仅提供风扇电机。所有的布线和相关零件的供应由最终客户确认。

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

L1

COIL HEATER 1

"WAGO"

TERMINALS

1

N

BLACK

COIL HEATER 2

2

BLACK

COIL HEATER 3

3

BLACK

TRAY HEATER

BLACK

4

L2

L3

COIL HEATER 4

BLACK

5

6

7

BLACK

BLACK

BLACK

BLACK

BLACK

(IF PRESENT)

8

E

ALL EARTH LEADS
TERMINATE HERE

EARTH POST

EARTH LEAD TO

"TERMINAL BLOCK COVER"

G / Y

G / Y

G / Y

FACTORY FITTED

SUPPLIED & WIRED
BY OTHERS

415 V, 3 Ph, 50 Hz

由他方供电和接线

 

工厂提供

 

盘管加热器

4

(如果有

 

盘管加热器

盘管加热器

盘管加热器

黑色线

 

接水盘管加热器

所有接地端在此

 

零线

 

地线

 

接地柱

 

绿

/

 

绿

/

 

绿

/

 

壳体接地

 

WAGO

 

接线排

 

黑色线

 

黑色线

 

黑色线

 

无锡新加坡工业园区新都路

12

邮编:

214028

电话:

0510-85282020

传真:

0510-85282242

西克制冷

(

无锡

)

有限公司

 

Summary of Contents for BOHN

Page 1: ...nd Clearance pg 3 Installation Instructions pg 4 a Lifting of Unit pg 4 b Unpacking of Unit pg 4 c Mounting the Unit pg 4 d Condensate Drain Line pg 5 e Refrigerant Distributor and Nozzle pg 5 f TX Va...

Page 2: ...Defrost Guidelines pg 7 a Defrost Termination Requirements pg 7 b Control Setting Guidelines pg 8 Routine Maintenance of Unit pg 8 General Decommissioning Guide pg 9 Material Safety Data Sheets M S D...

Page 3: ...l if it is inhaled and or makes contact with exposed skin Refrigerants used in this equipment are controlled substances and must be used and recovered responsibly It is against the law to deliberately...

Page 4: ...refrigerants For other refrigerants please refer to sales data sheet for capacity variations Low temperature range evaporators Kirby KHDF series are designed at 24 C SST and 6 KTD to suit room temper...

Page 5: ...1 C is preferred placement C D S2 S1 S2 S2 S1 S2 D is an alternative for the same reason as B D B Where one side of wall mounting will not accommodate all required units or air throw distance must be...

Page 6: ...ly with HACCP and or relevant regulations for food safety the area above the evaporator must be sealed or exposed in such a way to facilitate hand cleaning without the use of tools So depending on the...

Page 7: ...igerated room HACCP PVC 1 300mm U U To obtain the best performance of the evaporator the distributor body shall be mounted vertically to ensure refrigerant liquid being distributed evenly to all the c...

Page 8: ...e shall be taken during installation of the piping to prevent entrance of foreign matter or moisture by minimising the time that the piping is uncapped The interconnecting refrigeration pipe size is n...

Page 9: ...eets for all the information regarding voltage and current for fan motors and element heaters During field wiring fan motors shall be wired up in star connection After electrical installation units sh...

Page 10: ...rier will ensure all refrigerant supplied to the refrigeration system is clean and dry The sight glass is a useful device to ensure sufficient refrigerant is supplied to the refrigeration system Refri...

Page 11: ...avy Load represents the nominal working period of each day 3 X 12 20 Defrost time for average loads should be approx 20 25 minutes including drainage Time will vary with varying degrees of ice build u...

Page 12: ...iven as a guide During the commissioning this data should be used as a reference initially It is then necessary to fine tune the control settings to achieve the satisfactory defrost results The above...

Page 13: ...re designed to have low service maintenance requirements Based on normal operation conditions and working environment a service maintenance schedule shall be established after the successful completio...

Page 14: ...rost completely Look for abnormal accumulation of ice patterns and adjust the defrost cycles accordingly Check the superheat and adjust TX valve accordingly All power must be disconnected before clean...

Page 15: ...in a potential personal injury hazard Cut and solder seal the refrigeration liquid line and suction line pipe connections Remove the evaporator from its mounting place Adequate support must be provid...

Page 16: ...to providing safe products and protecting the environment by complying with all applicable national laws and regulations governing environmental protection New and used refrigerants cannot be vented...

Page 17: ...ED ALLOW 1000 MM MIN FOR AIRFLOW REMOVABLE OPENING ACCESS DOOR AIRFLOW LABEL CEILING MOUNTED ALLOW 600 MM MIN FOR AIRFLOW FOOT MOUNTED ALLOW 1000 MM MIN FOR AIRFLOW ALLOW 520 MM MIN FOR ACCESS PANEL O...

Page 18: ...2 IF PRESENT 3 Ph FAN MOTOR 3 IF PRESENT FUSE OR CIRCUIT BREAKER 415 V 3 Ph 50 Hz ISOLATION SWITCH BLACK BROWN BLUE G Y W2 U1 U2 V1 V2 W1 W2 U1 U2 V1 V2 W1 3 Ph FAN MOTOR 1 3 Ph FAN MOTOR 2 IF PRESEN...

Page 19: ...tion by customer L1 COIL HEATER 1 WAGO TERMINALS 1 N BLACK COIL HEATER 2 2 BLACK COIL HEATER 3 3 BLACK TRAY HEATER BLACK 4 L2 L3 COIL HEATER 4 BLACK 5 6 7 BLACK BLACK BLACK BLACK BLACK IF PRESENT 8 E...

Page 20: ...20070206 20 of 20...

Reviews: