46
Heat & Glo • 6000BEC-IPI, 6000BEC-IPILP • 2187-900 Rev. K • 4/15
PLUG-IN
3V TRANSFORMER
ON/OFF
WALL SWITCH
IGNITION
MODULE
(3V)
VALVE
NEUTRAL
GROUND
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL HOT
PLUG-IN
REMOTE
JUMPER WIRE
ORG
GR
N
BRN
BRN
RED
BLK
INTERMITTENT
PILOT IGNITOR
ORG
WHT
IGNITION MODULE 3 VAC
TRANSFORMER
VALVE
3 VAC
BLACK WIRE CAN BE
PLUGGED INTO ANY
OF #1 - #5 LOCATIONS
ON THE HOT SIDE
WHITE WIRE CAN BE
PLUGGED INTO ANY
OF#1 - #5 LOCATIONS
ON THE NEUTRAL SIDE
GROUND TO
FIREPLACE
CHASSIS*
THERMOSTAT WIRE
ASSEMBLY / WALL SWITCH
WIRE
D. Electrical Service and Repair
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Figure 12.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram
Note: Appliance will not operate