35
Heat & Glo • 6000BEC-IPI, 6000BEC-IPILP • 2187-900 Rev. K • 4/15
B. Rear Vent
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
NOTICE:
Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
Figure 9.7
Fold the tabs toward the center of the seal
cap (90º) and remove the insulation gasket.
Figure 9.8
Cut the metal retaining band and fold the
sides out.
Figure 9.9
Fold the center parts of the retaining band out
and use to remove the seal cap.
Figure 9.10
Discard the vent cap, remove and discard
the insulation basket.
Figure 9.11
Attach the
fi
rst vent section (it will snap into
place). Slide the insulation gasket onto the vent section,
up against the appliance and over the tabs.
NOTICE:
Once the seal cap has been removed it CANNOT
be reattached.
Figure 9.12 Non-combustible Board
C. Installing the Non-combustible Board
The factory supplied non-combustible board spans the
distance from the top of the
fi
replace to the center of
the framing header. This board must be used. See
Figure 9.12.
HEADER
HEADER