19
!
2. Continue Adding Vent Components
To continue adding vent components in accordance
with the pre-planned vent system configuration:
• Ensure that each
succeeding vent
component is securely
fitted and locked into
the preceding compo-
nent in the vent sys-
tem.
Continue adding vent
components, locking
each succeeding
component into place.
Figure 11. Adding Venting Components
90° elbows may be installed and rotated to any point
around the preceding component’s vertical axis. If an
elbow does not end up in a locked position with the
preceding component, attach with a minimum of two
(2) sheet metal screws.
WARNING: MODEL CFX-DIAMOND
REQUIRES SHIELD SRV570-290 ABOVE
THE FIRST 90° ELBOW IN THE SYSTEM
IF CLEARANCE IS LESS THAN 4 INCHES
(102MM). SEE INSTALLATION SHEET AND
HEAT SHIELD SUPPLIED WITH FIREPLACE.
Figure 12. Placement of SRV570-290 Heat Shield
First 90
0
elbow in system.
DIRECTION
UP
HEAT SHIELD
COMBUSTIBLE
SURFACE
90 ELBOW
0
DIRECTION
UP
HEAT SHIELD
COMBUSTIBLE
SURFACE
90 ELBOW
0
CORRECT
INCORRECT
HEAT SHIELD
COMBUSTIBLE
SURFACE
3” MIN.
(76mm)