Heat-N-Glo BE-41 Installer'S Manual Download Page 24

26

Step 8.  Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed

electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB-

SENT  FOR  EXTENDED  TIME  PERIODS.  THIS  WILL

PREVENT ACCIDENTAL FIREPLACE OPERATION.

For Standing Pilot Ignition Wiring
Appliance Requirements
• 

This appliance 

DOES NOT 

require 110-120 VAC to operate.

WARNING:  DO NOT CONNECT 110-120 VAC

TO THE GAS CONTROL VALVE OR THE AP-

PLIANCE  WILL  MALFUNCTION  AND  THE

VALVE WILL BE DESTROYED

.

!

!

Figure 30. Standing Pilot Ignition Wiring Diagram

Figure 31. Fan Wiring Diagram

Optional Accessories

Optional fan and remote control kits require that 110-120

VAC be wired to the factory installed junction box before

the fireplace is permanently installed.

Remote Wall Switch

Position the remote wall switch in the desired position on a

wall. Run a maximum of 25 feet (7.8 m) or less length of 18

A.W.G. minimum wire and connect it to the fireplace ON/

OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC

TO THE REMOTE WALL SWITCH OR THE

CONTROL VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-

TION WHEN SERVICING CONTROLS. WIRING ERRORS

CAN CAUSE IMPROPER AND DANGEROUS OPERATION.

VERIFY  PROPER  OPERATION AFTER  SERVICING.

FAN

TEMPERATURE

SENSOR SWITCH

SPEED CONTROL

(RHEOSTAT)

JUNCTION BOX

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE 
MUST BE REPLACED, IT MUST BE 
REPLACED WITH TYPE 105 C RATED WIRE.

O

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE

SENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLE

BLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

GAS VALVE

BLACK S1

THERMOPILE

WHITE T2

TH TP

TP

TH

RED T1

OPTIONAL REMOTE

OPTIONAL WALL SWITCH

BLACK S2

Summary of Contents for BE-41

Page 1: ...UTURE REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 Thisapplianceisonlyforusewiththetype of gas indica...

Page 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Page 3: ...10 Step 3 Installing the Vent System 12 A Vent System Approvals 12 B Installing Vent Components 18 C Vent Termination 21 Step 4 Positioning Leveling and Securing the Fireplace 24 Step 5 The Gas Contr...

Page 4: ...1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada 1Approvals and Codes High Altitude Installations U L Listed gas fireplaces are...

Page 5: ...eplace and its components are tested and safe when installed in accordance with this Installers Guide Report to your dealer any parts damaged in shipment particularly the condition of the glass Do not...

Page 6: ...unit is to be installed The vent system configuration to be used Gas supply piping Electrical wiring Framing and finishing details Whether optional accessories devices such as a fan wall switch or re...

Page 7: ...the face of the fireplace is one inch 25 mm The back of the fireplace may be recessed 21 1 2 inches 546 mm into combustible construction Minimum Clearances from the Vent Pipe to Combustible Materials...

Page 8: ...below shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING 1 2 CLEARANCE FROM BACK OF FIREPLACE TO COMBUSTIBLE 0...

Page 9: ...3 8 INCHES 34 93mm AT EACH JOINT DV 36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 48D 7 3 8 187mm 8 5 8 220mm 8 1 2 216mm 6 7 16 164mm 11 1 16 281mm 6 1 2 165mm 8 1 2 216mm 5 1 16 129mm 8 5 8 220mm 35...

Page 10: ...nting configuration used Terminations Kits Identifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical...

Page 11: ...Up Vertical Venting NOTE On vertical venting configurations where the vertical component is over 10 feet you may want to install the vertical baffle VERT BAF see Figure 7 STRAIGHT UP VERTICAL VENTING...

Page 12: ...e 90 Elbow VENTING WITH ONE 1 90 ELBOW VENTING WITH ONE 1 90 ELBOW V FT H FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H 40 MAX 12 4MM H 20 MAX...

Page 13: ...914 mm 6 MAX 1 86 m 15 MAX 4 65m 4 MIN 1 22 m 8 MAX 2 48 m 20 MAX 6 2m V H H1 40 MAX 12 4 m H 8 MAX 2 48 m H H1 20 MAX 6 2m Figure 12 Venting with Two 90 Elbows VENTING WITH TWO 2 90o ELBOWS V FT H H...

Page 14: ...914mm 6 MAX 1 86m 15 MAX 4 65m 4 MIN 1 22m 8 MAX 2 48m 20 MAX 6 2m V H H1 H2 40 MAX 12 4 m H 8 MAX 2 48 m H H1 H2 20 MAX 6 2 m V H H H1 H2 1 MIN 305mm 2 MAX 610mm 5 MAX 1 52m 2 MIN 610mm 4 MAX 1 22m...

Page 15: ...m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m NOTE H H1 20 MAX 6 2m V V1 H H1 40 MAX 12 4m V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX...

Page 16: ...inch 127mm fireplace starting collar Make sure that the fiberglass rope gasket supplied with the fireplace seals between the first 8 5 8 inch 219mm vent component and the outer fireplace wrap Lock th...

Page 17: ...e supports to the framing members Figure 17 Adding Venting Components For Vertical Runs The vent system must be supported every eight 8 feet 2 4m above the fireplace flue outlet by wall brackets To in...

Page 18: ...the vent passes To install firestops for vertical runs that pass through ceilings Position a plumb bob directly over the center of the verti cal vent component Mark the ceiling to establish the center...

Page 19: ...OR SIDING SEE THE FOL LOWING DIAGRAM FOR VENT TERMINATION CLEARANCES ROUND CAP TERMINATION PERFORATION CANNOT BE INSIDE THE WALL 7 1 2 191mm MINIMUM TRAPEZOID CAP TERMINATION 7 1 4 184mm WARNING THET...

Page 20: ...or that may be opened C 9 U S A 12 Canada clearance to permanently closed window D 18 vertical clearance to ventilated soffit located above the termi nal within a horizontal distance of 2 feet 60 cm f...

Page 21: ...FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMI NATION CAP IS AT LEAST TWO 2 FEET FROM A VERTICALWALLAND 2 FEET BELOWA HORIZON TAL OVERHANG NOTE This also pertains to vertical vent systems i...

Page 22: ...position level and secure the fireplace Figure 27 Proper Positioning Leveling and Securing of a Fireplace Step 5 The Gas Control Systems WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The type of g...

Page 23: ...vent cold air infiltration Open the fireplace lower grille insert the gas supply line throughthegaslinehole andconnectittotheshut offvalve When attaching the pipe support the control so that the lines...

Page 24: ...witch Position the remote wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails WA...

Page 25: ...NSI or CAN CGAtesting standardsdonot require hearth extensions for gas fireplace appliances Figure 33 Sealant Material HIGH TEMPERATURE SIDE SEAL JOINT 300 F 149 C MIN TOP O O 0 0 FINISH WALL MATERIAL...

Page 26: ...of the tie in the fireplace see Figure 35 WARNING USE WIRE CUT TERS DO NOT ATTEMPT TO CUT THE TIE WITH A KNIFE 3 Grasp the log assembly by the ends Do NOT grasp the log as sembly by the center Remove...

Page 27: ...rward on the refractory see Figure 37 7 Cut shrink wrap and remove from around the log assembly WARNING REMOVE ALL PACKAGING FROM LOGS 8 Install embers See ember placement instructions for details WAR...

Page 28: ...e chemicals used in the paint and logs Step 12 Lighting the Fireplace You ve reviewed all safety warnings you ve checked the fireplace for gas leaks you know the vent system is unobstructed and you ve...

Page 29: ...annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically B...

Reviews: