48
Service Manual
VMH SerieS
Heat Controller, Inc.
Appendix 5:
Spec.
Outdoor unit
Model
1x2
1x3
1x4
Compressor
DA130S1C-20FZ
DA150S1C-20FZ
TNB306FPGMC-L
Outdoor fan motor
YDK70-6FB
YDK70-6FB
YDK180-8GB
Indoor unit
Model
9k Mini-Split
12k Mini-Split
18k Mini-Split
Indoor fan motor
RPG20B
RPG20B
RPG28H
Model
/
12k Cassette
18k Cassette
Indoor fan motor
/
YDK45-6B
YDK45-6B
1. Compressor checking
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
DA130S1C-20FZ
DA150S1C-20FZ
TNB306FPGMC-L
Blue - Red
0.95
Ω(20
℃
)
0.95
Ω(20
℃
)
0.53
Ω(20
℃
)