Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13
10
I. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.3.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
optional remote. The unit should be in the OFF position
during installation, service, battery installation, , fuel
conversion, and in the event that the control goes into
LOCK-OUT mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI flame setting, with no adjustment in flame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from a wired wall switch and/or one of the optional
wireless remote options.
2. A wall switch can be wired into the control module brown
and red wires. See Figure 12.1.
3. The control module has safety feature that automatically
shuts down the fireplace after 9 hours of continuous
operation without receiving a command from the wall
switch or optional remote.
4. If you intend to use both a wired wall switch and an optional
remote control to operate your fireplace, the wall switch
will override any commands given by the remote.
Figure 2.3 Control Module
NG/LP GAS-TYPE
SELECTOR SWITCH
SELECTOR
SWITCH
FLAME HI/LOW
SWITCH
STATUS
INDICATOR LED
MODULE
Note:
The HI/LO and LP/NG switches on the control module
are non-functional on the XLR fireplace.
5.
Module Reset Switch
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying an error code at its status indicator LED.
• Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section H.
• Locate the module reset switch. See Figure 2.4 or 2.5.
• Set the module reset switch to the RESET position.
• Wait five (5) minutes to allow possible accumulated gas
to clear.
• Set the module reset switch to ON.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT
press the mod-
ule reset switch more than one time within a five minute
time period. Gas may accumulate in firebox. Call a quali-
fied service technician.
Figure 2.4 Location of Module Reset Switch - Tonic Front
MODULE RESET
SWITCH
Figure 2.5 Location of Module Reset Switch - Martini Front
MODULE RESET
SWITCH
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fireplace after nine hours of continuous
operation with receiving a command from the wall
switch or optional remote.