Figure 7.3

Top Vent - Horizontal Termination

Venting with 1 elbow

H

1

V

1

V Minimum

H

Maximum

90 Elbow

61,0 cm

30,5 cm

91,4 cm

61,0 cm

1,5 m

91,4 cm

2,1 m

120 cm

4,3 m

H Max. =4,3 m

V + H Max. = 12,2 m

Fire Risk.   Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling firestops.
•  ALWAYS maintain specified clearances around venting and firestop systems.
•  Install wall shield and ceiling firestops as specified.
Failure to keep insulation or other material away from vent pipe may cause fire.

WARNING

Note

: Use SLP Series 

components only.

Summary of Contents for XLR-N-CE

Page 1: ...esent or help is needed to properly install one HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or o...

Page 2: ... in this owner s manual unless noted otherwise applies to all models and gas control systems Your new Heat Glo gas fireplace will give you years of durable use and trouble free enjoyment Welcome to the Heat Glo family of fireplace products We recommend that you record the following pertinent information about your fireplace Serial Number Type of Gas The model information regarding your specific fi...

Page 3: ...on Considerations 16 C Tools and Supplies Needed 16 D Inspect Appliance and Components 16 5 Framing and Clearances A Selecting Appliance Location 17 B Constructing the Appliance Chase 18 C Clearances 19 D Mantel and Wall Projections 20 6 Termination Locations A Vent Termination Minimum Clearances 21 7 Vent Information and Diagrams A Approved Pipe 23 B Vent Table Key 23 C Use of Elbows 23 D Measuri...

Page 4: ...tting 51 H Media Options 51 15 Troubleshooting A IntelliFire Plus Ignition System 52 16 Component Access A Decorative Front and Fixed Glass Assembly Removal 54 B Valve Pressure Taps 54 C Control Module Access 54 D Media Tray Removal 54 E Burner and Base Pan Removal 54 F Access Through the Valve Assembly 55 G Gas Valve Replacement 56 H Pilot Assembly Replacement 56 17 Reference Materials A Applianc...

Page 5: ...al purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warra...

Page 6: ...lowing Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use ...

Page 7: ...es in force NOX Class 5 for G20 NOX Class 5 for G31 Natural Gas G20 Propane G31 Propane G31 Butane G30 Butane G30 Natural Gas G25 CAT I2H I2E I2E I3P I3P I3B P I3B P I2E Inlet Pressure 20 mbar 30 mbar 50 mbar 30 mbar 50 mbar 25 mbar Burner Pressure 8 7 mbar 25 mbar 25 mbar 25 mbar 25 mbar 8 7 mbar Gas Rate 405 m3 h 134 m3 h 134 m3 h 111 m3 h 111 m3 h 40 m3 h Heat Input Net 7 32 kW 6 74 kW 6 74 kW ...

Page 8: ...ISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away If you expect that small children or vulnerable adults may come into contact with this fireplace the following precau tions are recommended Install a physical barrier ...

Page 9: ...fastened to the base pan Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed D Decorative Doors and Fronts WARNING Risk of Fire Install ONLY doors or fronts approved by ...

Page 10: ...override any commands given by the remote Figure 2 3 Control Module NG LP GAS TYPE SELECTOR SWITCH SELECTOR SWITCH FLAME HI LOW SWITCH STATUS INDICATOR LED MODULE Note The HI LO and LP NG switches on the control module are non functional on the XLR fireplace 5 Module Reset Switch This module may lock out under certain conditions When this occurs the appliance will not ignite or respond to commands...

Page 11: ...floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE CONTROL VALVE Improper installation adjustment al teration service or maintenance can cause injury or property damage Re fer to the ...

Page 12: ...inishing materials and adhesives used near the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the curing process of the paint Glass should be cleaned within 3 to 4 hours of initial burning A non abrasive cleaner such as gas appliance glass cleaner may be neces sary See your dealer Metallic noise Noise...

Page 13: ...Doors Frequency Annually By Homeowner Tools needed Protective gloves stable work surface Refer to the installation instructions which ship with the decorative door Assess condition of screen and replace as necessary Inspect for scratches dents or other damage and repair as necessary Check that louvers are not blocked Vacuum and dust surfaces Venting Frequency Seasonally By Homeowner Tools needed P...

Page 14: ...uency Upon initial installation and gas valve re placement or service By Qualified Service Technician Tools needed Protective gloves manometer flashlight screw driver set Gas pressure taps are accessible by removing the deco rative front and fixed glass assembly Refer to Section 11 A for information related to the gas valve and gas pressure settings Burner Ignition and Operation Frequency Annually...

Page 15: ...WALL PENETRATION FRAMING SECTION 8 B VERTICAL TERMINATION CAP SECTION 10 H NON COMBUSTIBLE ROOF FLASHING MAINTAINS MINIMUM CLEARANCE AROUND PIPE SECTION 10 F STORM COLLAR SECTION 10 G VENT PIPE SECTIONS 7 and 8 CEILING FIRESTOP ON FLOOR OF ATTIC SECTION 8 C FRAMING HEADER SECTION 5 GAS LINE SECTION 11 WALL SWITCH FRAMING HEADED OFF IN CEILING JOISTS SECTION 8 C ATTIC INSULATION SHIELD NOT SHOWN MU...

Page 16: ...sponsibility for and the warranty will be voided by the following actions Installation and use of any damaged appliance or vent system component Modification of the appliance or vent system Installation other than as instructed by Hearth Home Technologies Improper positioning of the gas logs or the glass door Installation and or use of any component part not approved by Hearth Home Technologies An...

Page 17: ...or service access Due to high temperatures the appliance should be locat ed out of traffic and away from furniture and draperies NOTICE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference 2 54 cm A E A B C TOP VENT ONE 90º ELBOW ALCOVE INSTALLATION D TOP VENT ONE ...

Page 18: ... The chase should not break the outside building envelope in any manner The factory supplied non combustible board must be used in all installations It must be directly attached to structural framing adjacent to the appliance Screw fas teners should be installed in the pilot holes provided in the outer perimeter of the non combustible board See Figure 13 3 The factory supplied board is designed su...

Page 19: ... making contact with fireplace or chimney Failure to maintain airspace may cause overheating and a fire Note Figure 5 2 shows the fireplace installed on the floor However this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained C B D A Figure 5 2 Clearances to Combustibles H E I F J G MEASURE FROM ...

Page 20: ...th sides of opening UNLIMITED TOP VIEW 18 cm 8 cm MINIMUM 36 cm MIN 30 cm MAX 1 3 cm Thick Wall Sheathing MEASUREMENT FROM TOP OF FIREPLACE OPENING Note For non combustible fireplace finish material marble stone etc specifications refer to Section 13 C Mantel Leg Combustible Non Combustible 8 90 cm 2 5 cm AIR SPACE NON COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE 2 5 cm Figure 5 6 Non Combustible Zone...

Page 21: ...pe may cause overheating and fire WARNING Gas Wood or Fuel Oil Termination Cap B Gas Termination Cap A If using decorative cap cover s this distance may need to be increased Refer to the installation instructions supplied with the decorative cap cover In a staggered installation with both gas and wood or fuel oil terminations the wood or fuel oil termination cap must be higher than the gas termina...

Page 22: ...d soffits 1 There must be 91 m minimum between termination caps 2 All mechanical air intakes within 3 m of a termination cap must be a minimum of 91 m below the termination cap 3 All gravity air intakes within 91 m of a termination cap must be a minimum of 30 m below the termination cap See Note 1 See Note 2 Note 3 Local codes or regulations may require different clearances Note 4 Termination caps...

Page 23: ...s vent table key are used in the vent diagrams D Measuring Standards Vertical and horizontal measurements listed in the vent diagrams were made using the following standards Pipe measurements are shown using the effective length of pipe see Figure 7 2 Measurements are made from the appliance outer wrap not from the standoffs Horizontal terminations are measured to the outside mounting surface flan...

Page 24: ...cm 2 1 m 120 cm 4 3 m H Max 4 3 m V H Max 12 2 m Fire Risk Explosion Risk Do NOT pack insulation or other combustibles between ceiling firestops ALWAYS maintain specified clearances around venting and firestop systems Install wall shield and ceiling firestops as specified Failure to keep insulation or other material away from vent pipe may cause fire WARNING Note Use SLP Series components only ...

Page 25: ... H2 V1 Figure 7 4 1 Top Vent Horizontal Termination continued Top Vent Horizontal Termination Venting with 2 elbows Note Use SLP Series components only V Minimum H1 H2 Maximum 90 Elbow 30 5 cm 305 mm 61 0 cm 610 mm 1 2 m 914 mm 1 8 m 1 2 m 4 6 m H H1 Max 4 6 m V H H1 Max 12 2 m ...

Page 26: ...iercing screws to secure vent restrictor to firebox heat shield See Figure 7 7 Exhaust restrictors are recommended for these vertically terminated products which have excessive draft Exhaust restrictors will compensate for high draft and restore vi sual flame height If the vent configuration has a total vertical of 4 6 m 13 4 m an exhaust restrictor may be needed The exhaust restrictor can be loca...

Page 27: ...l Termination Venting with 2 elbows Note Use SLP Series components only V1 Minimum H Maximum V2 V1 V2 Minimum 90 Elbow 61 0 cm 15 2 cm 91 4 cm 45 7 cm 1 5 m 91 4 cm 2 1 m 1 1 m 4 6 m H Max 4 6 m V1 V2 H Max 12 2 m No specific restrictions on this value EXCEPT V1 V2 H cannot exceed 12 2 m ...

Page 28: ...Vertical Termination Venting with 3 elbows Note Use SLP Series components only V1 Minimum H1 H2 Maximum V2 V1 V2 Minimum 90 Elbow 30 5 cm 30 5 cm 61 0 cm 61 0 cm 1 2 m 91 4 cm 1 8 m 1 2 m 4 3 m H Max 4 3 m V1 V2 H1 H2 Max 12 2 m No specific restrictions on this value EXCEPT V1 V2 H1 H2 cannot exceed 12 2 m ...

Page 29: ... 2198 900 Rev L 3 13 Top Vent Vertical Termination Venting with 4 elbows Note Use SLP Series components only V1 Min H1 Max V2 Min H2 Max V3 Min 45 7 cm 1 2 m 1 2 m 1 2 m 1 0 m V1 V2 V3 H1 H2 Maximum 12 2 m V1 H1 V2 V3 H2 Figure 7 10 ...

Page 30: ... of the hole is one 2 54 cm above the center of the horizontal vent pipe Figure 8 1 Horizontal Venting Clearances To Combustible Materials A B 122 cm 120 cm A 25 4 cm 25 4 cm B DO NOT PACK WITH INSULATION OR OTHER MATERIAL B Wall Penetration Framing Combustible Wall Penetration Whenever a combustible wall is penetrated you must frame a hole for the wall shield firestop s The wall shield firestop m...

Page 31: ...ts when installed with a attic insulation shield It must be under joists between floors that are not insulated Refer to Figure 8 4 Secure with three fasteners on each side WARNING Risk of Fire DO NOT pack insu lation around the vent Insulation must be kept back from the pipe to prevent overheating Figure 8 3 Installing Ceiling Firestop ATTIC ABOVE A PIPE SLP A 22 95 cm A Figure 8 4 Installing the ...

Page 32: ...nd to maintain air space clearance Figure 8 5 Attic Insulation Shield BEND ALL TABS INWARD 90 TO MAINTAIN CLEARANCE AND PREVENT INSULATION FROM FALLING INSIDE INSERT 3 SCREWS BEND 3 TABS OUTWARD TO FASTEN TO CEILING FIRESTOP BEND REMAINING TABS INWARD 90 DEGREES TO MAINTAIN CLEARANCE Vaulted Ceiling Installation Remove one shield from box NOTICE Cut previously installed batt insulation to make roo...

Page 33: ...Figure 9 2 Elbow Shield Shown Installed If venting with a 90 degree elbow directly off of the top of the appliance the elbow heat shield must be repositioned as shown in Figure 9 2 If venting vertically or using a straight section of vertical pipe remove the elbow heat shield and discard by remov ing the two 1 4 in screws that secure the elbow heat shield to the top of the fireplace For all ventin...

Page 34: ... Nailing tabs are provided to secure the appliance to the framing members Bend out nailing tabs on each side Place the appliance into position Keep nailing tabs flush with the framing Level the appliance from side to side and front to back Shim the appliance as necessary It is acceptable to use wood shims underneath the appliance Secure the appliance to the framing by using nails or screws through...

Page 35: ...ng vent component is securely fitted and locked into the preceding component Commercial Multi family Multi level exceeding two sto ries or High Rise Applications For Installation into a commercial multi family multi level exceeding two stories or high rise applications All outer pipe joints must be sealed with high temperature 150 ºC minimum continuous exposure rating silicone including the slip s...

Page 36: ...ction and the outer flue of the slip section over the outer flue of the pipe section See Figure 10 3 Slide together to the desired length Figure 10 3 Slip Section Pilot Holes Figure 10 4 Screws into Slip Section Pilot hole Continue adding pipe as necessary following instructions in Assembling Pipe Sections NOTICE If slip section is too long the inner and outer flues of the slip section can be cut ...

Page 37: ...venting system on the ceiling and drill a small hole through the ceiling and roof at this point Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 3 mm larger than the support box outline Lower the support box through the hole in the roof until...

Page 38: ...eam of any exposed pipe sections that are located above the roof line G Assemble and Install Storm Collar CAUTION Risk of Cuts Abrasions or Flying Debris Wear protective gloves and safety glasses during instal lation Sheet metal edges are sharp Connect both halves of the storm collar with two screws see Figure 10 13 Wrap the storm collar around the exposed pipe section closest to the roof and alig...

Page 39: ...irements for Horizontal Termination WARNING Risk of Fire To prevent overheating and fire heat shields must extend through the entire wall thick ness DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap shown in Figure 10 17 Heat shields must overlap 3 8 cm minimum There are two sections of the heat shield One section is factory attached to the wall...

Page 40: ...riate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current local or national codes and refer to Section 6 of this manual CAUTION Risk of Burns Local codes may require in stallation of a cap shield to prevent anything or anyone from touching the hot cap Note When using termination caps with factory suppl...

Page 41: ... the gas line installation is complete all connections must be tightened and checked for leaks with a commercially available non corrosive leak check solution Be sure to rinse off all leak check solution following testing Fittings and connections may have loosened during shipping and handling WARNING Fire Risk Explosion Risk High pressure will damage valve Disconnect gas supply piping BEFORE press...

Page 42: ...disconnecting the electrical power and remov ing batteries if installed before proceeding with any maintenance to the appliance B IntelliFire Plus Ignition System Wiring Wire the appliance junction cord to 230 VAC for proper operation of the appliance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction cord to a switched cir cuit Incorrect wiring will override IPI safe...

Page 43: ... is an alternative access to the junction cord This can be accessed by removing the valve assembly See Figures 11 1 and 11 2 Figure 12 2 Junction Cord Information BLUE BROWN GREEN YELLOW Figure 12 3 Blower Circuit 240V BLOWER JUNCTION CORD AUX 300 CE GROUND TERMINAL TO FIREPLACE CHASSIS COUNTRY OF DESTINATION PLUG OPTIONAL F Blower An optional fan and auxilliary box are available for this applianc...

Page 44: ...TM E 136 standard may cause fire Non Combustible Materials Specification Material which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof Materials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763 shall be cons...

Page 45: ...l or install screws which may penetrate the low er cover panel as this will restrict required access to the glass battery back up and remote receiver See Figure 13 3 The appliance is designed to accept 1 3 cm wall sheath ing materials such as drywall plywood wood composites or non combustible materials The type of material used depends whether the installation is an Inside or Overlap Fit Method Re...

Page 46: ... at no more than 30 5 intervals along the joint length The wall board joints should be finished with a Taping Coat followed by at least two subsequent Finish Coats of joint compound FIREPLACE OPENING 43 cm TO 44 cm Figure 13 4 Required Fireplace Opening Height For the initial Taping Coat it is critical that a general purpose chemically hardening joint compound such as SHEETROCK Brand Durabond Sett...

Page 47: ...LED NON COMBUSTIBLE BOARD DRYWALL OR EQUIVALENT 1 2 cm NON COMBUSTIBLE FINISHING MATERIAL 0 2 5 cm THICK NON COMBUSTIBLE FINISHING MATERIAL 0 2 5 cm THICK TONIC DECORATIVE FRONT SHOWN 3 8 cm ABOVE STANDOFF Both the Tonic and Martini decorative fronts can be in stalled with an Overlap or Inside Fit method Overlap Requirement See Figure 13 7 Inside Fit requirement See Figure 13 8 and 13 9 Non Combus...

Page 48: ...ions Non combustible finishing materials up to 10 16 cm thick can be installed around the front left right top and bottom For the Tonic decorative front inside fit applications the decorative front must be installed tight to the finishing flanges and must not overlap any finish material Ensure that no non combustible finish materials are in stalled within 1 9 cm of the fireplace opening The 1 9 cm...

Page 49: ...IVE FRONT TN SLR MARTINI DECORATIVE FRONT MT SLR Figure 13 10 Tonic Decorative Front Figure 13 11 Martini Decorative Front Inside and Overlap Fit See Section 13 C Overlap Fit Only See Section 13 C A B D C E F TONIC FRONT Table 1 Dimensions of Tonic Decorative Front A Top of decorative front to bottom of appliance 67 cm B Bottom of decorative front to bottom of appliance 17 5 cm C Inside dimension ...

Page 50: ...acked broken or scratched Replace as a complete assembly Removing Fixed Glass Assembly 1 Remove the decorative front 2 Locate the two spring latches that are on the upper left and right of the fireplace 3 Use both index fingers to release spring latches See Figure 14 1 4 Allow glass to tilt forward Grasp glass on the upper right and left sides and lift glass up and out Replacing Fixed Glass Assemb...

Page 51: ...g The air shutter is preset at the factory Air Shutter Settings N P B XLR 0 16 cm 0 80 cm Full Open H Media Options Install only approved media options These options include MEDIA AMBER MEDIA BLACK MEDIA CLEAR MEDIA COBALT MEDIA BK2 GEMS MEDIA WH2 GEMS MEDIA GEMS PORC BASE XLR LOGS MEDIA STONES 2 ...

Page 52: ...ction in wir ing configuration or wiring harness Remove and reinstall the wiring harness that plugs into module Verify there is a tight fit Verify pilot assembly wiring to module Re move and verify continuity of each wire in wiring harness Replace any damaged components c Improper wall switch wiring Verify that 230 VAC power is ON to junction cord d Module not grounded Verify black ground wire fro...

Page 53: ...pilot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod c Module is not grounded Verify module is securely grounded to metal chassis of ap pliance Verify that wire harness is firmly connected to the module d Damaged pilot assembly or contami nated flame sensing...

Page 54: ...embly REMOVE SCREWS BURNER CLIP BASE PAN E Burner and Base Pan Removal Once the media tray is removed the burner assembly and base pan may be removed 1 Remove burner assembly by removing two screws that secure the burner to the pilot assembly bracket and remove the one screw that secures the burner clip that secures the burner to the base pan See Figure 16 4 2 Once the burner is removed the base p...

Page 55: ...epair 5 Replace gasket before reinstalling the valve assem bly Figure 16 7 Disconnect Gas Valve F Access Through the Valve Assembly The lower access cover panel is removable if finishing material has not been previously installed Remove media tray burner assembly and base pan To access components 1 Remove eleven screws around perimeter of valve as sembly that secure valve plate to the firebox bott...

Page 56: ...lot fitting from the valve assembly 4 Disconnect the orifice gas flex and gas ball valve flex from the 2 flare fittings 5 Unscrew 2 screws located under the pressure taps to remove the gas valve from the valve bracket 1 Disconnect the orange and white wires from the con trol module 2 Remove the pilot fitting from the valve assembly 3 Remove two screws that secure pilot assembly to the pilot bracke...

Page 57: ...es refer to Section 5 A B G Q C L D E H O F P N Ø I J K M S R GAS LINE ACCESS LEFT VIEW FRONT VIEW RIGHT VIEW NON COMBUSTIBLE ZONE PROVIDED WITH UNIT 2 54 cm STANDOFF T U ELECTRICAL ACCESS Figure 17 1 Appliance Dimensions Location Centimeters K 2 5 L 95 9 M 40 N 16 8 O 106 P 5 5 Q 15 2 R 43 8 S 46 4 T 65 7 U 24 8 Location Centimeters A 121 8 B 109 2 C 99 3 D 33 7 E 100 6 F 9 G 17 4 H 119 5 I 23 7 ...

Page 58: ...8 900 Rev L 3 13 58 29 5 cm 14 6 cm 18 1 cm 30 8 cm DRC RADIUS Cap Shield 35 2 cm 24 1 cm 356 cm DVP BEK2 DVP HPC Cap Brick Extension 35 2 cm 12 7 cm 30 2 cm COOL ADDM Cap Shield Figure 17 2 Vent Components B Vent Components Diagrams ...

Page 59: ...ength SLP PIPE SLP HVS Horizontal Pipe Support SLP FS Ceiling Firestop SLP WS Wall Shield Firestop B Vent Components Diagrams continued Figure 17 3 SLP Series Vent Components 66 0 cm DVP HSM B Extended Heat Shield Effective Height Length Pipe cm mm SLP4 10 2 102 SLP6 15 2 152 SLP12 30 5 305 SLP24 61 610 SLP36 91 4 914 SLP48 121 9 1219 SLP6A 5 15 51 152 SLP12A 5 30 51 305 ...

Page 60: ... TVHW Vertical Termination Cap SLP CCS BK Cathedral Ceiling Support Box Black SLP DCF BK Ceiling Firestop Black SLP WT BK Wall Thimble Black B Vent Components Diagrams continued SL 2DVP Adapter Figure 17 4 SLP Series Vent Components SLP90 SL 2DVP DVP FBHT DVP FBHT 17 8 cm 39 4 cm 30 5 cm ...

Page 61: ...heat shields must be field tricmed If wall thickness is greater than 18 4 cm a DVP HSM B will be required Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 7 9 cm 12 1cm Trap2 13 3 cm 23 5 cm 20 3 cm 30 5 cm Max Effective Length 33 0 cm 38 1 cm 20 6 cm 27 6 cm 26 7 cm 3 87 Effective Length 14 6 to 21 3 cm 14 0 cm 21 3 cm SLP HRC SS SLP HRC ZC SS HORIZONTAL TERMINATION CA...

Page 62: ...serial number All parts listed in this manual may be ordered from an authorized dealer ITEM DESCRIPTION COMMENTS PART NUMBER 1 Sheet Rock Ledge 2184 147 2 Lower Cover Panel 2184 103 3 Top Panel Finish Edge 2292 102 4 Non Combustible Board 2198 405 5 Media Tray 2198 114 6 Burner N 2184 007 Burner P B 2198 007 7 Base Pan 2198 115 8 Glass Door Assembly GLA SLR 9 Junction Cord 2166 374 10 Thermostat W...

Page 63: ...4 1 Pilot Shield 2184 123 14 2 Pilot Assembly N 2090 012 Pilot Assembly P B 2090 013 14 3 Pilot Bracket 2198 174 14 4 3 Hole Grommet 2118 420 14 5 Bulkhead W Flex Tube 383 302A 14 6 Male Connector Pkg of 5 303 315 5 14 7 Valve Bracket 2198 153 14 8 Valve N 2166 308 Valve P B 2166 309 14 9 Module Wire Assembly 2166 304 14 10 Module 2166 306 14 11 Flex Ball Valve Assembly 2098 320A 14 12 Power Suppl...

Page 64: ...t Shield 2143 168 Exhaust Restrictor 530 299 Gasket Assembly 2113 080 Contains burner neck shutter bracket vent seal cap valve plate and air passage gaskets Glass Latch Assembly Pkg of 2 33858 2 Heat Shield Inner 2198 130 Jumper Wire Wall Switch 2179 300 Nailing Tabs 2198 132 Rocker Switch 2206 299 Switch Assembly Reset 2264 060 Touch Up Paint TUP GBK 12 Wall Switch Kit WSK 21 W Wire Jumper 2187 1...

Page 65: ...____________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this ma...

Reviews: