7
Heat & Glo • TRUE-36, TRUE-42, TRUE-50 Installation Manual • 2282-980 Rev. F • 8/14
3
3
Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Figure 3.1 Appliance Dimensions (TRUE-36)
Appliance Dimensions Table TRUE-36
Location Inches
Millimeters
J
24
610
K
23-1/2
597
L
59-1/4
1505
M
16
406
N
29-5/8
752
O
3-7/8
98
P
2-3/4
70
Q
10-7/8
276
R
16-1/8
410
Location Inches
Millimeters
A
61
1549
B
35-7/8
911
C
39-7/8
1013
D
31-1/16
789
E
57-5/8
1464
F
35-3/16
894
G
34-3/16
868
H
54-15/16
1395
I
41-3/8
1051
A
B
D
C
E
I
L
M
N
O
P
R
Q
GAS
ACCESS
ELECTRICAL
ACCESS
J
K
HEAT-ZONE
®
PORT
HEAT-ZONE
®
PORT
H
F
G
APPLIANCE DIMENSION DIAGRAM (TRUE-36)