47
Heat & Glo • SOHO-B-CEB, SOHO-N-CEB, SOHO-P-CEB • 2111-980 Rev. i • 3/13
12
Electrical Information
Figure 12.1 IPI Wiring Diagram
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
Optional Remote Control Receiver Location
The control module and remote control receiver can be
accessed through the air space below the firebox front
and the lower access door.
The IPI control module and the remote control receiver
are placed on the firebox bottom.
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
A. Wiring Requirements
NOTICE:
This appliance must be installed by a qualified
electrician in accordance with the relevant national and
local regulations.
• Wire the appliance junction box to 230 VAC. This is
required for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
230 VAC to the valve or to the appliance wall switch. In-
correct wiring will damage controls.
NOTICE:
The mains supply to the appliance must have
isolation of a minimum 3 mm contact separation in both
poles.
WARNING! Risk of Injury!
The gas supply shall be shut
off prior to disconnecting the electrical power and remov-
ing batteries (if installed) before proceeding with any
maintenance to the appliance.
B. IntelliFire Plus™ Ignition System Wiring
• Wire the appliance junction box to 230 VAC for proper
operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IntelliFire Plus™ Pilot Ignition (IPI)
Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus™
control valve which operates on a 6 volt system.
• An in-line isolation switch must be installed within 1
meter of the fireplace. This is required for servicing and/
or resetting the control module in the event of a control
module LOCK-OUT.
• Plug the 6 VAC power supply into the appliance junction
box to supply power to the unit.
GREEN
(MAIN)
ORANGE
(PILOT)
8K1 WIRE
HARNESS
GROUND
CONTROL MODULE
OPTIONAL ON/OFF
WALL SWITCH
RED
BLACK
BATTERY PACK
6V DC (C X 4)
BROWN
S
I
GROUND
TO CHASSIS
TO CORD ASSEMBLY
120VAC
WALL SWITCH
JUMPER WIRE
MODULE RESET
SWITCH
WIRE ASSEMBLY
OPTIONAL
JUNCTION CORD
WHITE
ORANGE
GAS TUBE
FLAME
SENSE
IGNITOR
No Fan Option