Gas Information 

 

A. Fuel Conversion

•  Make sure the appliance is compatible with available gas 

types.

•  Conversions must be made by a qualified service 

technician using Hearth & Home Technologies specifi ed 
and approved parts.

B. Gas Pressure

•  Optimum appliance performance requires proper input 

pressures.

•  Gas line sizing requirements will be determined in ANSI 

Z223.1 National Fuel Gas Code in the USA and CAN/
CGA B149 in Canada.

•  Pressure requirements are:

WARNING! Risk of Fire or Explosion! High pressure 
will damage valve. Low pressure may cause explosion.

•  Verify inlet pressures. Verify minimum pressures when 

other household gas appliances are operating. 

•  Install regulator upstream of valve if line pressure is 

greater than 1/2 psig.

Gas Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 in. w.c.

11.0 in. w.c.

Maximum inlet pressure

10.0 in. w.c.

13.0 in. w.c.

Manifold pressure

3.5 in. w.c.

10.0 in. w.c.

Fire Risk.

Explosion Hazard.

High pressure will damage valve.

•  Disconnect gas supply piping BEFORE 

pressure testing gas line at test pressures 
above 1/2 psig.

•  Close the manual shutoff valve BEFORE 

pressure testing gas line at test pressures 
equal to or less than 1/2 psig.

WARNING

Note: 

This appliance does include a manual gas shutoff valve 

that is located in the valve compartment. This manual gas 
shutoff valve is accessible for service by removing the base 
pan, burner assembly and valve plate.  See Figure 11.1.  

The lower access cover panel is removable if fi nishing 
material has not been previously installed.

Figure 11.1 Cover Tray Removal 

MEDIA TRAY/BASE PAN 
ASSEMBLY SCREWS

PILOT BRACKET  SCREWS

Figure 11.2.  Remove Valve Plate Screws

3.  Set the valve bracket on the front lip of the fi rebox bot-

tom.  Turn “off” the ball valve.  Disconnect gas valve 
from the gas fl ex ball valve assembly at the pressure 
fi tting.  See Figure 11.4.

Figure 11.3.  Remove Valve Plate

Access Through the Valve Assembly

The lower access cover panel is removable if fi nishing 
material has not been previously installed.

Remove media tray, base pan and burner assembly.  

To access components:

1. Remove eleven screws around perimeter of valve 

plate that secure valve plate to the fi rebox  bottom.  
See Figure 11.2.

2.  Lift the valve plate from the back so that the gas valve 

can clear the valve plate hole in the bottom the fi rebox.  
See  Figure 11.3.

Summary of Contents for SLR-C (COSMO)

Page 1: ...he rating plate Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies suggests NFI certified or factory trained professionals or technicians supervised by an NFI certified professional Leave this manual with party responsible for use and operation DO NOT DISCARD WARNING Important operating and maintenance instructions included Read understan...

Page 2: ...ise utilise avec avec un un combustible combustible solide solide This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes codes if if any any if if not not follow follow ANSI ANSI Z223 1 Z223 1 in in the the USA USA or or CAN CGA CAN CGA B149 B149 installation installation codes codes Installer Installer l appareil l appareil selon ...

Page 3: ...ical Appliance System 15 B Design and Installation Considerations 16 C Tools and Supplies Needed 16 D Inspect Appliance and Components 16 5 Framing and Clearances A Selecting Appliance Location 17 B Constructing the Appliance Chase 18 C Clearances 19 D Mantel and Wall Projections 20 6 Termination Locations A Vent Termination Minimum Clearances 22 7 Vent Information and Diagrams A Approved Pipe 24 ...

Page 4: ...liance Setup A Remove Fixed Glass Assembly 57 B Remove the Shipping Materials 57 C Clean the Appliance 57 D Accessories 57 E Glass Rock Media Kit 57 F Fixed Glass Assembly 59 G Install the Mesh 59 H Air Shutter Setting 59 15 Troubleshooting A IntelliFire Ignition System 60 16 Reference Materials A Appliance Dimension Diagram 62 B Vent Components Diagrams 63 C Service Parts 68 D Contact Information...

Page 5: ...e In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period...

Page 6: ...lowing Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use ...

Page 7: ...e is tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential heating calculations D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your local gas utility or authorities having jurisdiction When installing above 2000 feet elevation In the USA R...

Page 8: ...ing appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas inspector of the side wall horizon tally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector ob serves carbon monoxide detectors and signage installed in accordance...

Page 9: ...ow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls...

Page 10: ... install one For more information refer to the instructions supplied with your decorative door or front F Remote Controls Wall Controls and Wall Switches Follow the instructions supplied with the control installed to operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if...

Page 11: ...because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE CONTROL VALVE Improper installation adjustment al teration service or maintenance can cause injury or property damage Re fer to the owner ...

Page 12: ...should be cleaned within 3 to 4 hours of initial burning A non abrasive cleaner such as gas appliance glass cleaner may be nec essary See your dealer Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the fireplace Rock Media Kit There may...

Page 13: ...ve you many years of trouble free service We recommend an nual service by a qualified service technician Doors Surrounds Fronts Frequency Annually By Homeowner Tools needed Protective gloves stable work surface Assess condition of screen and replace as necessary Inspect for scratches dents or other damage and repair as necessary Check that louvers are not blocked Vacuum and dust surfaces Remote Co...

Page 14: ...e all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk broom flashlight voltmeter indexed drill bit set and a manometer Verify burner is properly secured and aligned with pilot or igniter Clean off burner top inspect for plugged ports corrosion or deterioration Re...

Page 15: ...PENETRATION FRAMING SECTION 8 B VERTICAL TERMINATION CAP SECTION 10 H NON COMBUSTIBLE ROOF FLASHING MAINTAINS MINIMUM CLEARANCE AROUND PIPE SECTION 10 F STORM COLLAR SECTION 10 G VENT PIPE SECTIONS 7 and 8 CEILING FIRESTOP ON FLOOR OF ATTIC SECTION 8 C FRAMING HEADER SECTION 5 GAS LINE SECTION 11 WALL SWITCH FRAMING HEADED OFF IN CEILING JOISTS SECTION 8 C ATTIC INSULATION SHIELD NOT SHOWN MUST BE...

Page 16: ...peration DO NOT install damaged in complete or substitute components Keep appliance dry C Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Tape measure Framing material Pliers Non corrosive leak check solution Hammer Phillips screwdriver magnetic Gloves Framing square Voltmeter Electric drill and bits 1 4 in magnetic P...

Page 17: ... Actual installation may vary due to individual design preference 1 IN A E A B C TOP VENT ONE 900 ELBOW ALCOVE INSTALLATION D TOP VENT ONE 90 ELBOW B F Figure 5 1 Appliance Locations A B C D E F Inches 53 1 32 48 75 See Section D Figure 5 5 5 6 19 9 32 17 3 4 Millimeters 1347 1218 1905 490 451 Unlike many traditional single sided Heat Glo fireplaces the SLR C is recessed into surrounding framing T...

Page 18: ...ness To further prevent drafts the wall shield and ceiling fire stops should be caulked with caulk with a minimum of 300ºF continuous exposure rating to seal gaps Gas line holes and other openings should be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with unfaced insulation If the appliance is being installed on a cement surface a layer of plywood may be placed...

Page 19: ...pace may cause overheating and a fire C B D A Figure 5 2 Clearances to Combustibles H E MEASURE FROM TOP OF FIREPLACE OPENING I F J G Note Figure 5 2 shows the fireplace installed on the floor However this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained MINIMUM FRAMING DIMENSIONS A B C D E F G ...

Page 20: ... sides of opening Figure 5 6 Non Combustible Mantel Leg or Wall Projections Acceptable on both sides of opening Combustible Mantel Legs Or Wall Projections Extending Past The Face Of The Fireplace Non combustible Mantel Legs Or Wall Projections Extending Past The Face Of The Fireplace 3 FT MAXIMUM 6 IN MINIMUM 2 IN MINIMUM FIREPLACE OPENING 3 IN MINIMUM UNLIMITED 7 IN FIREPLACE OPENING Note For no...

Page 21: ...21 Heat Glo SLR C 2292 900 Rev H 2 13 3 1 2 IN 1 IN AIR SPACE NON COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE 1 IN Figure 5 8 Non Combustible Zone ...

Page 22: ...H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 6 6 Termination Locations Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or other materials Failure to keep insulation or other materials away from vent pipe may cause overheating and fire WARNING Gas Wood or Fuel Oil Termination Cap B Gas Termination Cap A If using decorative cap cover...

Page 23: ...rical Service V K V K V L C V N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 42 inches vinyl soffit and overhang P 8 ft QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMAX 2 termination caps x QACTUAL Covered Alcove Applications Spaces open only o...

Page 24: ...and horizontal measurements listed in the vent diagrams were made using the following standards Pipe measurements are shown using the effective length of pipe see Figure 7 2 Measurements are made from the appliance outer wrap not from the standoffs Horizontal terminations are measured to the outside mounting surface flange of termination cap Vertical terminations are measured to bottom of terminat...

Page 25: ...firestops ALWAYS maintain specified clearances around venting and firestop systems Install wall shield and ceiling firestops as specified Failure to keep insulation or other material away from vent pipe may cause fire WARNING Note Use SLP Series components only Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 3 CAUT...

Page 26: ...5 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 15 ft 4 6 m H1 H2 MAX 15 ft 4 6 m V H1 H2 MAX 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 3 CAUTION The SLP HRC SS and SLP HRC ZC SS termination caps are not approved for use with pro pane LP fuel May lead to elev...

Page 27: ... 610 mm 12 ft 3 7 m 3 ft 914 mm 14 ft 4 3 m H1 H2 MAX 14 ft 4 3 m V1 V2 H1 H2 MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H cannot exceed 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 3 CAUTION The SLP HRC SS and SLP HRC ZC SS termination caps are not approved for use with pr...

Page 28: ...ZONTALLY Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 3 V Minimum H1 H2 H3 MAXIMUM SLR C NG ONLY 3 ft 914 mm 15 ft 4 6 m H1 H2 H3 MAX 15 ft 4 6 m V1 MAX 7 ft 2 1 m CAUTION The SLP HRC SS and SLP HRC ZC SS termination caps are not approved for use with pro pane LP fuel May lead to elevated glass temper ature that...

Page 29: ...iercing screws to secure vent restrictor to firebox heat shield See Figure 7 10 Exhaust restrictors are recommended for these vertically terminated products which have excessive draft Exhaust restrictors will compensate for high draft and restore vi sual flame height If the vent configuration has a total ver tical of 15 44 feet an exhaust restrictor may be needed The exhaust restrictor can be loca...

Page 30: ...V2 Minimum 90 Elbow 2 ft 610 mm 1 ft 152 mm 3 ft 914 mm 2 ft 457 mm 5 ft 1 5 m 3 ft 914 mm 7 ft 2 1 m 4 ft 1 1 m 15 ft 4 6 m H MAX 15 ft 4 6 m V1 V2 H MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H cannot exceed 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 3 ...

Page 31: ...imum V2 V1 V2 Minimum 90 Elbow 1 ft 305 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 14 ft 4 3 m H MAX 14 ft 4 3 m V1 V2 H1 H2 MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H1 H2 cannot exceed 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 ...

Page 32: ...components only Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 5 3 V1 MIN H1 MAX V2 MIN H2 MAX V3 MIN 1 1 2 ft 457 mm 4 ft 1 2 m 4 ft 1 2 m 4 ft 1 2 m 3 1 2 ft 1 0 m V1 V2 V3 H1 H2 Maximum 40 ft 12 2 m Figure 7 13 V1 H1 V2 V3 H2 ...

Page 33: ...me Technologies recommends that NFI or CSIA certified professionals or technicians under the direction of certi fied professionals conduct a minimum of a NFPA 211 Level 2 inspection of the chimney Replace component parts of the chimney and fireplace as specified by the professionals Ensure all joints are properly engaged and the chimney is properly secured EXHAUST VENT PIPE INLET AIR VENT PIPE Fig...

Page 34: ... DV 46DVA GCL adapter with three self tapping screws TOP VENT WARNING Risk of Fire Explosion or Asphyxiation Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance May impair safe operation of this appliance or other appliances connected to the flue Vent this appliance directly outside Use separate vent system for this appliance NOTICE To achieve...

Page 35: ...2 Wall Penetration Shows center of vent framing hole for top venting The center of the hole is one 1 in 25 4 mm above the center of the horizontal vent pipe Figure 8 1 Horizontal Venting Clearances To Combustible Materials A B 48 1 16 in 47 1 16 in A 10 in 10 in B DO NOT PACK WITH INSULATION OR OTHER MATERIAL B Wall Penetration Framing Combustible Wall Penetration Whenever a combustible wall is pe...

Page 36: ...hen installed with a attic insulation shield It must be under joists between floors that are not insulated Refer to Figure 8 5 Secure with three fasteners on each side WARNING Risk of Fire DO NOT pack insu lation around the vent Insulation must be kept back from the pipe to prevent overheating Figure 8 4 Installing Ceiling Firestop ATTIC ABOVE A PIPE SLP A 9 in 229 mm A Figure 8 5 Installing the A...

Page 37: ...d to prevent blown insulation from getting between the shield and vent pipe and to maintain air space clearance Figure 8 6 Attic Insulation Shield BEND ALL TABS INWARD 90 TO MAINTAIN CLEARANCE AND PREVENT INSULATION FROM FALLING INSIDE INSERT 3 SCREWS BEND 3 TABS OUTWARD TO FASTEN TO CEILING FIRESTOP BEND REMAINING TABS INWARD 90 DEGREES TO MAINTAIN CLEARANCE Vaulted Ceiling Installation Remove on...

Page 38: ... 9 2 Elbow Shield Shown Installed If venting with a 90 degree elbow directly off of the top of the appliance the elbow heat shield must be repositioned as shown in Figure 9 2 If venting vertically or using a straight section of vertical pipe remove the elbow heat shield and discard by remov ing the two 1 4 in screws that secure the elbow heat shield to the top of the fireplace For all venting appl...

Page 39: ... are provided to secure the appliance to the framing members Bend out nailing tabs on each side Place the appliance into position Keep nailing tabs flush with the framing Level the appliance from side to side and front to back Shim the appliance as necessary It is acceptable to use wood shims underneath the appliance Secure the appliance to the framing by using nails or screws through the nailing ...

Page 40: ...rely fitted and locked into the preceding component Commercial Multi family Multi level exceeding two sto ries or High Rise Applications For Installation into a commercial multi family multi level exceeding two stories or high rise applications All outer pipe joints must be sealed with silicone with a minimum of 300ºF continuous exposure rating including the slip section that connects directly to ...

Page 41: ...r flue is not required All unit collar pipe slip section elbow and cap outer flues shall be sealed Maintain a 1 1 2 in 38 mm overlap between the slip section and the pipe section Secure the pipe and slip section with two screws no longer than 1 2 in 13 mm using the pilot holes in the slip section See Figure 10 4 C Secure the Vent Sections Vertical runs originating off the top of the appliance with...

Page 42: ...ceiling and drill a small hole through the ceiling and roof at this point Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 1 8 in 3 mm larger than the support box outline Lower the support box through the hole in the roof until its bottom is ...

Page 43: ...brasions or Flying Debris Wear protective gloves and safety glasses during instal lation Sheet metal edges are sharp Connect both halves of the storm collar with two screws see Figure 10 13 Wrap the storm collar around the exposed pipe section closest to the roof and align brackets Insert a bolt provided through the brackets and tighten the nut to complete the storm collar assembly Make sure the c...

Page 44: ...ING Risk of Fire To prevent overheating and fire heat shields must extend through the entire wall thick ness DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap shown in Figure 10 17 Heat shields must overlap 1 1 2 in 38 mm mini mum There are two sections of the heat shield One section is factory attached to the wall shield firestop The other sect...

Page 45: ... cap base Flash and seal as appropriate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current ANSI Z223 1 and CAN CGA B149 installation codes and refer to Section 6 of this manual CAUTION Risk of Burns Local codes may require in stallation of a cap shield to prevent anything or anyone from touching the h...

Page 46: ...ssures above 1 2 psig Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1 2 psig WARNING Note This appliance does include a manual gas shutoff valve that is located in the valve compartment This manual gas shutoff valve is accessible for service by removing the base pan burner assembly and valve plate See Figure 11 1 The lower access cover pane...

Page 47: ...ions could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your local gas utility or authorities having jurisdiction When installing above 2000 feet elevation In the USA Reduce burner orific...

Page 48: ...unction C Optional Accessories Requirements This appliance may be used with a wall switch wall mounted thermostat and or a remote control 12 12 Electrical Information Optional Remote Control Receiver and Battery Pack Location Batteries are to be installed only when battery power is required Because of the limited accessibility to valve cavity the position of the battery pack IPI control module and...

Page 49: ...junction box heat shield such that it is positioned over the junction box TRANSFORMER 3 VAC PLUG IN BLACK RED BATTERY PACK WIRE ASSEMBLY WIRES TO BROWN ORANGE GREEN VALVE WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S GROUND TO FIREPLACE CHASSIS NOTE 1 Ignition module valve pilot and wall switch operate on 3 volts 120 VAC is required at junction box unless equipped w...

Page 50: ...ustible Materials Specification Material which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof Materials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC shall be considered non combustible materials Setting the Firepl...

Page 51: ...factory installed non combustible board See Figure 13 3 Note It is acceptable to use a silicone sealant with a minimum of 300ºF continuous exposure rating to adhere drywall to lower cover panel Note Refer to Section 13 C regarding installation details associated with the Inside and Overlap Fit methods Do not drill or install screws which may penetrate the lower cover panel as this will restrict re...

Page 52: ...stible board should be fastened to the framing with at least 1 1 4 in long screw fasteners located within 1 1 2 in from each corner and at no more than 12 inch intervals along the joint length The wall board joints should be finished with a Taping Coat followed by at least two subsequent Finish Coats of joint compound For the initial Taping Coat it is critical that a general purpose chemically har...

Page 53: ...7 Combustible Mantel Leg or Wall Projections Acceptable on both sides of opening Figure 13 8 Non Combustible Mantel Leg or Wall Projections Acceptable on both sides of opening Combustible Mantel Legs Or Wall Projections Extending Past The Face Of The Fireplace Non combustible Mantel Legs Or Wall Projections Extending Past The Face Of The Fireplace 3 FT MAXIMUM 6 IN MINIMUM 2 IN MINIMUM FIREPLACE O...

Page 54: ...N ABOVE STANDOFF Overlap Requirement See Figure 13 9 Inside Fit requirement See Figure 13 10 and Figure 13 11 C Facing Material Facing and or finishing materials must not interfere with air flow through louvers operation of louvers or doors or access for service Facing and or finishing materials must never overhang into the glass opening Observe all clearances when applying combustible materials W...

Page 55: ...nside Fit Method Tonic Decorative Front Only Non Combustible Finish Materials 0 Inches to 4 Inches Thick Inside Fit Method The Tonic decorative front is approved for inside fit ap plications Non combustible finishing materials up to 4 inches thick can be installed around the front left right top and bottom For the Tonic decorative front inside fit applications the decorative front must be installe...

Page 56: ... in Section 1 B of this installa tion manual A B D C E F TONIC FRONT A Top of decorative front to bottom of appliance 26 3 8 in 670 mm B Bottom of decorative front to bottom of appliance 6 7 8 in 175 mm C Inside dimension of decorative front width 39 in 991 mm D Outside dimension of decorative front width 44 1 2 in 1130 mm E Inside dimension decorative front height 12 7 8 in 327 mm F Outside dimen...

Page 57: ...glass rock particles An easy method to clean the glass rock media is to empty the contents of the bag into a bucket and rinse thoroughly with a garden hose Allow the glass rock media to dry before installing into the fireplace Installation 1 Position rock media placement jig over pilot shield to prevent inadvertent glass rock media placement in front of pilot shield 2 Figure 14 1 shows the outline...

Page 58: ...DASHED LINES WARNING Risk of Fire DO NOT place glass rock me dia directly in front of the pilot assembly or between the burner tracks over the burner ports NOTICE Care should be taken to avoid placing glass rock media between the left right and back edges of the media tray and the firebox Blocking this gap may cause an undesirable flame appearance See Figure 14 4 BURNER TRACKS ...

Page 59: ...ass Assembly 1 Remove the decorative front 2 Locate the two spring latches that are on the upper left and right of the fireplace 3 Use both index fingers to release spring latches See Figure 14 5 4 Allow glass to tilt forward Grasp glass on the upper right and left sides and lift glass up and out Replacing Fixed Glass Assembly 1 Locate glide tabs on lower left and right corners 2 Grasp glass on up...

Page 60: ...r ing configuration or wiring harness Remove and reinstall the wiring harness that plugs into module Verify there is a tight fit Verify pilot assembly wiring to module Re move and verify continuity of each wire in wiring harness Replace any damaged components c Improper wall switch wiring Verify that 110 120 VAC power is ON to junction box d Module not grounded Verify black ground wire from module...

Page 61: ...ice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod c Module is not grounded Verify module is securely grounded to metal chassis of appliance Verify that wire harness is firmly connected to the module d Damaged pilot assembly or contami nated flame sensing rod Verify...

Page 62: ...S R GAS LINE ACCESS LEFT VIEW FRONT VIEW RIGHT VIEW 1 INCH STANDOFF ELECTRICAL ACCESS A B C D E T U Figure 16 1 Appliance Dimensions Location Inches Millimeters K 1 25 L 37 3 4 959 M 15 3 4 400 N 6 5 8 168 O 41 3 4 1060 P 2 3 16 55 Q 6 152 R 17 1 4 438 S 18 1 4 464 T 25 7 8 657 U 9 3 4 248 Location Inches Millimeters A 48 1218 B 43 1092 C 39 1 16 993 D 13 1 4 337 E 39 5 8 1006 F 3 9 16 90 G 6 7 8 ...

Page 63: ...m DVP HSM B Extended Heat Shield Effective Height Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 6 51 152 SLP12A 2 12 51 305 SLP FLEX 2 24 610 SLP FLEX 3 36 914 SLP FLEX 5 60 1524 SLP FLEX 10 120 3048 SLP FLEX PIPE EFFECTIVE HEIGHT LENGTH SLP HVS Horizontal Pipe Support 10 7 8 in 276 mm 8 7 8 in 225 mm 1 1 2 in 38 mm SLP FS Ceiling Firestop...

Page 64: ... in 269 mm 14 in 356 mm SLP CCS BK Cathedral Ceiling Support Box Black 12 1 2 in 318 mm 12 in 305 mm SLP TVHW Vertical Termination Cap 13 in 330 mm 13 in 330 mm 1 5 16 in 34 mm SLP DCF BK Ceiling Firestop Black SLP WT BK Wall Thimble Black 14 7 16 in 367 mm 14 7 16 in 367 mm 2 5 16 in 59 mm SL 2DVP Adapter 3 15 16 in 101 mm 6 11 16 in 169 mm 8 in 203 mm 3 15 16 in 101 mm 3 13 16 in 97 mm 5 1 16 in...

Page 65: ...lap by a minimum of 1 1 2 in 38 mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness is greater than 7 1 4 in 184 mm a DVP HSM B will be required Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 3 1 8 in 4 3 4 in 79 mm 121mm...

Page 66: ...PV Wire Harness PVI WH20 40 ft PV Wire Harness PVI WH40 60 ft PV Wire Harness PVI WH60 80 ft PV Wire Harness PVI WH80 100 ft PV Wire Harness PVI WH100 PVI SLP Power Vent Inline SLP LPC SLP Low Profile Cap Note Wire harnesses required to power the PVI SLP connect to the appliance and are ordered separately from PVI SLP Contact your dealer to order 16 IN 406 mm 15 IN 381 mm 16 11 16 IN 424 mm 9 3 16...

Page 67: ...in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DVP HPC Cap Brick Extension 13 7 8 in 352 mm 5 in 127 mm 11 7 8 in 302 mm PVK 80 For use with IPI and DSI appliances only 11 1 2 in 292 mm 12 1 2 in 318 mm 16 in 406 mm 9 in 229 mm 2 3 4 in 70 mm 12 1 4 in 311 mm Figure 16 6 Vent Components B Vent Components Diagrams ...

Page 68: ...TS PART NUMBER 1 Sheet Rock Ledge 2184 147 2 Lower Cover Panel 2184 103 3 Top Panel Finish Edge 2292 102 4 Non Combustible Board 2198 405 5 Base Pan 2292 010 6 Burner Assembly 2292 007 Y 7 Glass Door Assembly GLA SLR Y 8 Junction box 4021 013 Y 9 Bracket Junction Box 2195 154 10 Nailing Tab Qty 2 req 2198 200 Additional service part numbers appear on following page 2 13 42 Gas Fireplace DV SLR C C...

Page 69: ... 582 057 Y 11 4 Valve Bracket 2269 153 11 5 Valve NG 593 500 Y Valve LP 593 501 Y 11 6 Male Connector Pkg of 5 303 315 5 Y 11 7 Module Wire Assembly 593 590A Y 11 8 Thermostat Wire Assembly 2118 170 Y 11 9 Flex Ball Valve Assembly 531 320A Y 11 10 3 Volt Transformer 593 593A Y 11 11 Battery Pack 593 594A Y 11 12 Module 593 592 Y 11 13 Bulkhead W Flex Tube 383 302A Y 11 14 Grommet 2118 420 11 15 Pi...

Page 70: ...ered from an authorized dealer Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Elbow Heat Shield 2143 168 Exhaust Restrictor 530 299 Gasket Assembly 2113 080 Contains burner neck shutter bracket vent seal cap valve plate and air passage gaskets Glass Latch Assembly Pkg of 2 33858 2 Y Heat Shield Inner 2198 130 Touch Up Paint TUP GBK 12 Black Rock 10 Lb Bag 2188 850 Conversion Kit NG N A Con...

Page 71: ...______________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ Printed in U S A Copyright 2013 DO NOT DISCARD THIS M...

Reviews: