Heat & Glo • SL-7BV Owner’s Manual • 2395-981 Rev. F • 1/19
6
B. Glass Specifications (Tempered)
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as defined by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certified to the re
-
quirements of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing Certification Council
SGCC# 1595
and
1597
. Architectural Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Sec-
tion 1201.5
“Certification and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certificate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
A. Appliance Certification
2
Product Specific Information
C. BTU Specifications
Models
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input BTU/h
Orifice
Size
(DMS)
SL-7BV
(NG)
(0-2000 FT)
25,500
19,000
42
SL-7BV
(Propane)
(0-2000 FT)
22,000
17,000
54
MODELS:
SL-7BV
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Vented Decorative Gas Appliances
STANDARD:
ANSI Z21.50-2016 • CSA 2.22-2016
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
NOT INTENDED FOR USE AS A HEAT SOURCE.
This appliance is decorative in nature and not intended to be
a source of heat.
NOT FOR USE WITH SOLID FUEL.
This appliance is not intended to burn solid fuel.
This product is listed to ANSI standards for “Vented
Decorative Gas Appliances.” Also Certified for Installation
in a Bedroom or a Bedsitting Room.
This product is listed to ANSI standards for “Vented
Decorative Gas Appliances.” May be installed in a sleeping
room when the provisions for combustion, ventilation and
dilution air are met per the requirements of ANSI 223.1/
NFPA 54 National Fuel Gas Code. In Canada, installation
in a sleeping room requires installation with a thermostat
certified for use with this product. Consult your local
authorities having jurisdiction.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.