37
Heat & Glo • SL-550/750TR-E, SL-550/750/950TR-IPI-E Installation Manual • 2118-910 Rev. C • 4/16
B. Rear Vent
NOTICE:
Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
NOTICE:
Once the seal cap has been removed it CANNOT
be reattached.
Figure 6.8
Fold the tabs toward the center of the
fi
re plug
(90°) and remove the insulation gasket.
Figure 6.9
Cut the metal retaining band and fold the
sides out.
Figure 6.10
Fold the center parts of the retaining band
out and use to remove the seal cap.
Figure 6.11
Discard the seal cap, remove and discard
the insulation basket. Note: Once the vent cap has been
removed it CANNOT be reattached.
Figure 6.12
Attach the
fi
rst vent section (it will snap into
place). Slide the insulation gasket onto the vent section,
up against the appliance and over the tabs. Use two self-
tapping screws to secure gasket to outer wrap.
Figure 6.7
To attach the
fi
rst section of vent pipe, make
sure to use the
fi
berglass gasket to seal between the
fi
rst
vent component and the outer
fi
replace wrap. Use 2 self-
tapping screws to secure the gasket to the outer wrap.
Note:
Once the vent cap has been removed, it cannot be
reattached.
2 SCREWS