Heat & Glo • SL-550/750TR-E, SL-550/750/950TR-IPI-E Installation Manual • 2118-910 Rev. C • 4/16
Figure 4.13
Top Vent - Vertical Termination - (continued)
Two Elbows
H
1
V
1
V
2
V
1
MIN.
SL-550TR-E
SL-550TR-IPI-E
SL-750TR-E
SL-750TR-IPI-E
SL-950TR-IPI-E
H MAX.
H MAX.
H MAX.
V
2
V
1
+ V
2
MIN.
90 Elbow
1-1/2 ft.
457 mm
1-1/2 ft.
457 mm
1 ft.
305 mm
*
*
1/2 ft.
152 mm
2 ft.
610 mm
2 ft.
610 mm
2 ft.
610 mm
*
*
1-1/2 ft. 457 mm
3 ft.
914 mm
3 ft.
914 mm
3 ft.
914 mm
*
*
2-1/2 ft. 762 mm
5 ft.
1.5 m
5 ft.
1.5 m
5 ft.
1.5 m
*
*
3-1/2 ft.
1.1 m
7 ft.
2.1 m
7 ft.
2.1 m
7 ft.
2.1 m
*
*
4-1/2 ft.
1.4 m
15 ft.
4.6 m
15 ft.
4.6 m
15 ft.
4.6 m
*
*
H MAX. =15 ft. (4.6 m)
V
1
+ V
2
+ H MAX. = 40 ft. (12.2 m)
* No speci
fi
c restrictions on this value EXCEPT V
1
+ V
2
+ H cannot exceed 40 ft. (12.2 m)
Note
: There MUST be a 25%
reduction in total H when using
fl
ex vent except when using the
simple up and out installation.
See Figure 4.6.
Note
: Use SLP Series
components only.