Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
52
B. Wiring Requirements
IntelliFire Plus
TM
Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IntelliFire Plus
TM
Pilot Ignition (IPI)
Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
TM
control which operates on a low voltage system.
• Plug the 6-volt AC transformer into the appliance junction
box to supply power to the appliance.
FAN
INTERMITTENT
PILOT IGNITOR
ORANGE
WHITE
SENSOR
WIRE
IGNITER
WIRE
6VDC TRANSFORMER
ELECTRICAL
ACCESS KNOCKOUT
APPLIANCE ON/OFF CONTROL
HARNESS
THERMO SNAP DISC
HARNESS
JUMPER
HARNESS
AUX300
MODULE
WALL SWITCH
JUMPER WIRE
IPI WIRE
HARNESS
MALE/FEMALE
WIRE ASSEMBLY
8K1-PVI
ORANGE
GREEN
GREEN
VALVE
JUMPER
JUMPER
JUMPER
HI LIMIT SWITCHES
GROUND TO
FIREPLACE CHASSIS
JUNCTION BOX
TO POWER VENT
BROWN
RED
ORANGE
AUX 2
BLACK
WHITE
Figure 8.2 RED60 IntelliFire Plus Wiring Diagram
(Wire colors subject to change)