Heat & Glo • RED60 • 2159-900 Rev. B • 12/09
24
F. Installation Instructions and Venting In-
formation - PVI-DVP
These instructions are for appliances utilizing the PVI-DVP
that is factory-installed for the RED60 model. For appli-
ances incorporating the PVK-80, see Section 7.J.
IMPORTANT:
Failure to read and follow these instruc-
tions may create a possible hazard and will void the fi re-
place warranty.
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
INTRODUCTION
The PVI-DVP is certifi ed for use only on fi replaces manufac-
tured by Hearth & Home Technologies with IPI (intermittent
pilot ignition) gas controls.
The PVI operates on 120VAC, 60Hz electrical service which
is supplied at the fi replace junction box.
Components and Service Parts List
Service Parts List
Replacement parts can be obtained from your dealer. Re-
pair of the Power Vent should only be done by a qualifi ed
service technician. A list of replacement parts is shown
in Figure 7.4.
INSTALLATION OF PVI-DVP
1. INSTALLATION PRECAUTIONS
a. This device must be installed by a qualifi ed installer in
accordance with these instructions.
b. Safety inspection of the venting system should be
performed before and after installation of this power
vent. Consult local code offi cials and follow applicable
installation codes.
c.
DO NOT INSTALL DAMAGED EQUIPMENT OR VENT
COMPONENTS.
d. The exit termination of mechanical draft systems shall
not be less than seven feet above grade when located
adjacent to public walkways and at least ten feet from
lot line or adjacent buildings.
e. A mechanical drafting venting system shall terminate at
least three feet above any forced air inlet located within
ten feet.
f. Disconnect electrical power supply before making wiring
connections.
g. Venting of more than one appliance in a common vent
system is prohibited.
Figure 7.4 Replacement Parts List
VACUUM SWITCH
2196-301
BLOWER ASSEMBLY
2196-025
Optional Wire Harness
DESCRIPTION
PART NUMBER
10 ft. PV Wire Harness
PVI-WH10
20 ft. PV Wire Harness
PVI-WH20
40 ft. PV Wire Harness
PVI-WH40
60 ft. PV Wire Harness
PVI-WH60
80 ft. PV Wire Harness
PVI-WH80
100 ft. PV Wire Harness
PVI-WH100
2. INSTALLATION GUIDELINES
WARNING: RISK OF FIRE AND BURNS. DO NOT in-
stall PVI with the access panel facing upward. Over-
heating may occur.
a. If the PVI-DVP is being installed in a confi ned space
(such as a utility closet, mechanical room or attic space)
with a total volume less than 720 cubic ft, an 8 inch by
16 inch hole will be required above the access panel to
accommodate fresh air. This hole may be covered with
a decorative cover as long as the cover has a minimum of
50% open air. This also applies to a fi replace chase.
If the PVI-DVP is being installed in a space greater than
720 cubic ft the 8 inch by 16 inch access hole is still
required, but a solid cover may be used.
The decorative cover
CANNOT
be located on an outside
wall that is open to the environment.
b. For installations near loose-fi ll insulation (such as attics)
a minimum clearance of six inches must be maintained
between the access panel and the insulation.
CAUTION: Failure to install, operate, and maintain the
power venting system in accordance with manufacturer's
instructions will result in conditions which may produce
bodily injury and/or property damage.
h. Clearances between the vent pipe and combustible ma-
terials must be maintained at 3-inch top, 1-inch sides,
and 1/2 inch bottom.
i. All outer pipe joints must be sealed with high tempera-
ture silicone. See Section10.A.
CAUTION: Failure to install, operate, and maintain the
power venting system in accordance with manufacturer's
instructions will result in conditions which may produce
bodily injury and/or property damage.