Heat & Glo LifeStyles Collection • Montana-42C • 4039-155 Rev D • 03/06
22
A. Gas Log/Lighter Provisions
A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.
This fi replace was not teste3d and listed for use with an un-
vented gas log heater. Do not install an unvented gas log
heater in this fi replace and operate it with the fl ue damper in
the closed position unless the unvented gas log heater has
been specifi cally tested and listed for use in this fi replace by
Underwriters Laboratories Inc.
Use of an unvented gas log heater in this factory built
fi replace may create a fi re hazard that can result in a
structure fi re.
• Maximum input is 100,000 BTU/hr.
•
Decorative gas appliance must be certifi ed to
ANSI Z21.60
“Standard for Decorative Gas Appliances for Installation
in Vented Fireplaces”.
• Must be installed in accordance with the
National Fuel
Gas Code, ANSI Z223.1.
• A log set must incorporate a gas shutoff.
• Log set requires the damper to be locked fully open.
Knockouts are provided on both sides of the fi replace and in
refractories for 1/2 in. (13 mm) iron pipe.
• We recommend you seal refractory around pipe with
fi replace mortar or cement.
• Repack insulation from the knockout around the pipe.
• Maintain 1-1/2 in. (38 mm) air space around the pipe for
4 in. (102 mm) beyond the fi replace.
• See
Figure
7.1.
Firebox
Repack
Insulation
Knockout
Combustible
Materials
Maintain air clearance
to combustibles.
Gas Line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
Gas Line
1-1/2 in.
(38 mm)
air space
Refractory
Seal with
fireplace mortar
or cement
4 in.
(102 mm)
Outer Shell
of Fireplace
Figure 7.1
Gas Line Installation
7
Accessories
Asphyxiation Risk
•
Damper must be locked open when gas logs
installed.
Gas fi re generates fumes.
WARNING
Fire Risk
• For use with solid wood fuel or decorative
gas appliance only.
• DO NOT install unvented gas logs.
WARNING
Fire Risk
Explosion Risk
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components
Report damaged parts to dealer.