Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the fireplace is permanently installed.
Wall Switch
Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCON-
NECTION WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. VERIFY PROPER OPERATION AFTER
SERVICING.
Figure 35. Intensifire Switch Wiring Diagram
SWITCH
BATTERY
HOLDER
9 VOLT
MANIFOLD ASSEMBLY
RED
RED
WHITE
Figure 34. Intermittent Pilot Ignition (IPI) Wiring Diagram
Appliance Requirements
This appliance requires 110-120 VAC be wired to the factory
installed junction box. Maintain correct polarity when wir-
ing the junction box.
Step 9. Wiring the Fireplace
Intermittent Pilot Ignition (IPI) Wiring
3 Volt Transformer
This appliance comes with a 3 volt transformer. The trans-
former plugs into the junction box and the two leads plug
into the green control module (see Figure 34).
Intensifire Switch
This model is equipped with an intensifire switch. This switch
allows you to turn On/Off the rear log burners. The switch is
located on the control panel. Install the 9 volt battery into
the battery holder located in the lower compartment right
next to the control panel (see Figure 35).
IGNITION MODULE
3 VAC
TRANSFORMER
3 VAC
G
RN
O
RG
INTERMITTENT
PILOT
IGNITOR
IGNITION
MODULE
(3V)
ON/OFF
WALL
SWITCH
LOW VOLTAGE
PLUG-IN
3V TRANSFORMER
NEUTRAL
HOT
GROUND
FLAME SPARKER/
SENSOR
REMOTE
CONTROL
SEE NOTE 1
ORG
WHT
VALVE
PIGGYBACK
ON/OFF SWITCH
WHITE WIRE
CAN BE
PLUGGED
INTO ANY
OF #1-#5
LOCATIONS
ON THE
NEUTRAL SIDE
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
BRN
BR
N
VALVE
PLUG IN
GROUND TO
FIREPLACE
CHASSIS
I
S
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Uninterrupted or continuous power is
required at all times in IPI system EXCEPT
when using battery back-up.
• Incorrect wiring will override IPI safety lockout and may
cause explosion.