HORIZONTAL VENTING
Kit No.
H Max. Run
DVP-TRAP
24" (610 mm)
Figure 11. Corner Installation
NOTE: This model is tested and approved to use
45° elbows in corner installations. However, 90°
elbows will result in better performance. The
use of two 90
0
elbows in a corner installation
will affect space requirements (see Figure 2).
45-DEGREE
ELBOW
90-DEGREE
ELBOWS
H
3.
Match the amount of vertical you have in the sys-
tem with the chart to find the appropriate position
to set the Flue Restrictor (see Figure 9).
1 2 3 4 5
SETTINGS
1 2 3 4 5
Figure 10
- CHART -
Vertical
Top Vent
NG
Top Vent
LP
Rear Vent
NG
Rear Vent
LP
4'
1-1
No
Restrictor
No
Restrictor
No
Restrictor
8'
2-2
1-2
1-1
No
Restrictor
15'
3-3
3-2
2-2
1-2
20'
3-4
3-3
3-3
2-3
25'
3-4
3-3
3-3
2-3
30'
4-4
3-4
3-4
3-3
35'
4-4
3-4
3-4
3-3
40'
5-4
4-4
4-4
3-4
4
. Center the Flue Restrictor on vent and secure in
place by using two self-tapping screws.
5.
Reinstall the Exhaust Shield.
Figure 9