4
Heat & Glo • 6000GBV, 6000GBV-IPI • 2104-900 Rev. G • 9/08
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured with
tempered glass may be installed in hazardous locations
such as bathtub enclosures as defi ned by the Consumer
Product Safety Commission (CPSC). The tempered glass
has been tested and certifi ed to the requirements of
ANSI
Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing Certifi cation
Council
SGCC# 1595
and
1597
. Architectural Testing, Inc.
Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR
Section 1201.5
“Certifi cation and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
A.
Appliance Certifi cation
NOTE:
This installation must conform with local codes. In the
absence of local codes you must comply with the
National
Fuel Gas Code, ANSI Z223.1-latest edition
in the U.S.A.
and the
CAN/CGA B149 Installation Codes
in Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
Listing and Code Approvals
C. BTU Specifi cations
1
MODELS: 6000GBV, 6000GBV-IPI,
6000GBV-LP, 6000GBV-IPILP
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: B-Vent Decorative
STANDARD: ANSI Z21.50-2002•CGA2.2
Models
U.S. (0-2000 ft.) or Canada (2000-4500 ft.)
Maximum
Input BTUH
Minimum
Input BTUH
Orifi ce
Size
(DMS)
6000GBV
6000GBV-IPI
US
27,000
18,000
#40
CAN
24,300
16,200
#41
6000GBV-LP
6000GBV-IPILP
US
27,000
18,000
#53
CAN
24,300
16,200
#54
This product is listed to ANSI standards for “Vented Gas
Fireplaces” and “Gas Fired Appliances for Use at High
Altitudes”.
This model (natural gas and propane) can be installed in a
bedroom (in the United States) which has a total volume of
unconfi ned space appropriate to the particular installation.
Refer to the
National Fuel Gas Code ANSI Z223.1/
NFPA54 (current edition), The Uniform Mechanical
Code - (current edition)
, and local Building Offi cials for the
options allowed in obtaining an effective bedroom volume
of unconfi ned space.
This model (natural gas and propane) can be installed in
a bedroom (in Canada) if a thermostat (
Model WH-STAT
)
is installed with the unit. Consult local code authorities.
Detailed installation instructions for Model WH-STAT are