23
Heat & Glo • 6000GBV, 6000GBV-IPI • 2104-900 Rev. G • 9/08
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
E. Junction Box Installation
F. Wall Switch Installation for Fan (Optional)
Figure 10.4 Junction Box Detail
Figure 10.5 Fan Control Switch Wiring
If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.5):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using
a minimum of 14-3 with ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire to
the wall switch as shown.
• At the appliance connect the black
(hot), white (neutral) and green
(ground) wires to the junction box as
shown.
• Add a 1/4 inch insulated female con-
nector to the red (switch leg) wire,
route it through the knockout in the
face of the junction box, and connect
to the top fan switch connector (1/4
inch male) as shown.
• Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle to the
outer shell.
NOTE:
Do NOT wire
110VAC to wall switch.
R ed
R ed
B lack
B lack
G reen
G reen
W hite
W hite
Re
d
Bl
ac
k
Gr
ee
n
Wh
it
e
S W ITC H B O X
JU N C TIO N B O X
P O W E R
S U P P LY W IR E S
S W ITC H
M IN IM U M 14-3 AW G
W ITH G R O U N D
If the box is being wired from the
OUTSIDE
of the
appliance:
• Remove the cover plate located on the outer
shell - right side (see Figure 10.4).
• Install the Romex
™
connector in the cover
plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reat-
tach the cover plate to the outer shell.
If the box is being wired from the
INSIDE
of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box/receptacle inward to disengage it from the
outer shell (see Figure 10.4).
• Pull the electrical wires from outside the appli-
ance through this opening into the valve com-
partment.
• Feed the necessary length of wire through the
connector.