17
Heat & Glo • 6000CL-IFT, 8000CL-IFT Owner’s Manual • 2504-981 Rev. K • 12/20
Glass Cleaning
Frequency:
Seasonally
By:
Homeowner
Tools Needed
: Protective gloves, glass cleaner, drop
cloth and a stable work surface.
CAUTION!
Handle fixed glass assembly with care.
Glass is breakable.
• Avoid striking, scratching or slamming glass
•
DO NOT
use abrasive cleaners
•
DO NOT
clean glass while it is hot
•
Prepare a work area large enough to accommodate fixed
glass assembly and decorative front by placing a drop
cloth on a flat, stable surface.
Note
: Fixed glass assembly and gasketing may have res
-
idue that can stain carpeting or floor surfaces.
•
Remove decorative front from fireplace and set aside
on work surface.
WARNING!
Risk of Asphyxiation!
Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
•
DO NOT
strike, slam or scratch glass.
•
DO NOT
operate fireplace with glass removed, cracked,
broken or scratched.
•
Replace as a complete assembly.
Removing Fixed Glass Assembly
• Pull the four glass assembly latches out of the groove
on the glass frame. Remove glass assembly from the
appliance See Figure 4.1.
• Clean glass with a non-abrasive commercially available
cleaner.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer)
• Carefully set fixed glass assembly in place on fireplace.
Hold glass in place with one hand and secure glass
latches with the other hand.
Replacing Fixed Glass Assembly
• Replace the glass assembly on the appliance. Pull out
and latch the four glass assembly latches into the groove
on the glass frame.
• Inspect and operate all glass latches to ensure they
move freely and no obstructions are present.
• Reinstall decorative front.
Decorative Fronts/Surrounds
Frequency:
Annually
By:
Homeowner
Tools needed
: Protective gloves, stable work surface
• Assess condition of screen and replace as necessary.
• Inspect for scratches, dents or other damage and repair
as necessary.
•
Check that fireplace openings are not blocked.
•
Vacuum and dust surfaces.
Remote Control
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Replacement batteries and remote con-
trol instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Replace batteries as needed in remote transmitters and
battery-powered receivers.
• Place remote control out of reach of children.
If not using your fireplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
• Remove batteries from remote controls.
• Unplug 6 volt adapter plug on IPI models.
Venting
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such as plants, bird nests, leaves, snow,
debris, etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and flashing remains
intact.
• Inspect draft shield to verify it is not damaged or missing.
Figure 4.1 Fixed Glass Assembly
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM