background image

8

www.heartlandMicroPayments.com

Internal Mounting 

– Direct on 

Machine Panel

3

For Internal mounting directly onto the 
machine, please perform the following steps:  

1.

Locate a space on the machine that will 
properly accommodate the WaveReader.

2.

Using the template supplied on this page, cut out 
the area inside the dashed lines.  The opening is 

2.75” wide and .75” high

.  The dashed gray 

circles can be used as drill locations for the ¾” drill 
(or progressive) bit.  After drilling, a jig-saw can be 
used to finish the cuts. 

3.

The black circles above the gray area should be 
drilled using the 3/16” bit.

4.

Insert the WaveReader through the opening.  The 
four drilled holes should line up with the mounting 
holes in the back of the WaveReader.

5.

After making the cut and drilling the holes, attach 
the WaveReader to the machine with the 

four 

screws (3)

provided in the kit. Do not fully tighten 

the screws.

6.

Make sure to 

level the Wave Reader 

on the 

machine and fully tighten the mounting screws.

Direct-on-Machine 

Template

Note: For all 

stack

Speed Queen 

models, this process 

must be performed 

TWICE per 

machine.  

Make sure there is enough 

room to accommodate two 

readers!

Summary of Contents for Speed Queen

Page 1: ...WaveRider Installation INTERNAL MOUNTING www heartlandMicroPayments com 2115 Chapman Road Suite 159 Chattanooga TN 37421 800 332 4835 PULSE MODE COIN CARD ...

Page 2: ...es to the WaveReader installation process following Alliance Speed Queen model numbers If you cannot locate the model number of the machine you require in the lists above please contact MicroPayments Customer Service at Tel 800 332 4835 Press 2 Washers STEB77 stack w d Dryers SSGT09 ...

Page 3: ...ws Required Tools Installation Kit Contents T 20 Pin in Star Torx Driver Phillips Head Screwdriver medium 3 16 Drill Bit 3 4 Drill Bit or Step Drill bit to match 11 32 Nut Driver or Socket Ratchet Electric Drill Heavy Duty Jig Saw w Bi Metal blades Optional Hydraulic Punch with 3 0 Dia Knockout ...

Page 4: ...nts for the installation process If you cannot locate and or identify any of the components listed above please contact MicroPayments Customer Service at 800 332 4835 then press 2 KIT HRN 050 6 012 Harness Kit for Speed Queen Coin Card Item Qty Part Number Description 1 1 ASM 050 6 012 Stuffed Speed Queen Coin Drop board 2 1 AYS 050 6 009 Cable Speed Queen Pulse for WR Coin ...

Page 5: ...x 1 8 Pan Head Phillips Internal Mounting Trim Plate Kit 1 2 3 4 There are two methods of installing a WaveReader internally into a coin card laundry machine They are Internal Mounting Trim Plate Kit Internal Mounting Direct on Machine Panel Both methods are detailed in the following pages You should decide which method works best for you Both methods require certain minimum clearances surface are...

Page 6: ...w heartlandMicroPayments com Internal Mounting Minimum Required Dimensions Required Internal Depth Clearance 875 3 4 4 0 Required surface space Cut Drilled Opening Required Surface Area and Cutaway Openings ...

Page 7: ...e center hole 3 and use a 3 circular punch to remove the area marked by the dashed interior circle 2 4 After making the cut attach the WaveReader to the Surface Mount Cover Plate 1 with the four screws 3 provided in the kit 5 Insert the WaveReader Front Plate through the opening 6 Attach the Rear Backing Plate 2 with the two nuts 4 provided in the kit and finger tighten 7 Make sure to level the Wa...

Page 8: ... saw can be used to finish the cuts 3 The black circles above the gray area should be drilled using the 3 16 bit 4 Insert the WaveReader through the opening The four drilled holes should line up with the mounting holes in the back of the WaveReader 5 After making the cut and drilling the holes attach the WaveReader to the machine with the four screws 3 provided in the kit Do not fully tighten the ...

Page 9: ...er has been physically installed in the machine www heartlandMicroPayments com 2 Physically install the WaveReader using one of the methods described on pages 7 or 8 of this manual Make sure the machine is disconnected from all power sources and all metal fragments from the drilling and cutting are removed before reassembly Remove all screws and fasteners so that you can remove the front panel and...

Page 10: ...lation www heartlandMicroPayments com 4 Connect J1 of the interface harness back of the WaveReader 3 After physical installation the reader should look like this with the Trim Plate Kit This a view from the side ...

Page 11: ...the connector may be labeled H4 www heartlandMicroPayments com 5 6 On the main panel connect J3 of the WaveReader harness to the H1 connector on the Speed Queen control board in the yellow box 7 On the control board locate the plug where the coin drop is connected It should be a small three 3 pin plug that routes out of the H3 connector from the control board Disconnect it ...

Page 12: ... 9 Connect the Coin Drop into the other side of the Coin Adapter Board Locate the Coin Adapter Board Connect J4 of the WaveReader harness to the mating connector on the Coin Adapter Board 10 Locate the Serial Jumper on the control board and remove it ...

Page 13: ...nstallation 11 www heartlandMicroPayments com The completed wiring assembly should look like this Wiring Diagram 12 13 Using zip ties secure all wiring harnesses to prevent pinching wire strain and chafing ...

Page 14: ...ved for proper operation 2 For Quantum style machines operating in Pulse Mode all cycle prices must be set to the same value 3 The Start Value Pulse PLSE must be set to the same coin value as the WaveReader s Typically this value is 25 The programming steps for this are detailed in Step 23 Finished assembly 15 Apply the self adhesive sticker that displays the accepted card brands supplied in a cle...

Page 15: ...nts com PLSE Programming special care should be paid to this setting The modified excerpt below is from Speed Queen s MDC Frontload Washer Programming Manual and is provided for convenience Please refer to your machine s manual for confirmation ...

Page 16: ...s to be operating and the machines linked to it before testing can be performed 20 1 Drop 25c into the coin drop 2 Verify that 25c is deposited into the machine 3 Swipe a card wait for the transaction to be approved and then press START on the WaveReader 4 Verify that the balance of the funds have been deposited into the machine and it is ready to start Reattach all machine panels 18 ...