HearthStone
Quality Home Heating Products
MODEL Sterling “G” Direct-Vent
32
S
AFETY
L
ABEL
SERIAL #
8700-
MODEL NAME: STERLING-G DIRECT VENT GAS FIREPLACE HEATER
LISTED GAS-FIRED DIRECT VENT FIREPLACE HEATER, RADIATEUR VENTILE
TESTED TO: ANSI Z21.88-1998 CSA 2.33-M98
VENTED GAS FIREPLACE HEATERS
CAN/CGA - 2.17
CERTIFIED FOR CANADA/HOMOLOGUE POUR LE CANADA
APPROVED FOR MOBILE HOME INSTALLATION
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF
ANY; IF NOT, FOLLOW THE CURRENT EDITIONS OF ANSI Z223.1 (U.S. INSTALLATION)
OR CAN1-B149 (CANADIAN INSTALLATION). FOR MOBILE HOME INSTALLATION,
INSTALL PER THE MANUFACTURED HOME CONSTRUCTION ANS SAFETY
STANDARD, TITLE 24 CFR, PART 3280 (U.S.) OR CAN/CSA Z240 MH (CANADA).
INPUT RATING (Btu/hr) 0-1370 m
ORIFICE SIZE (DMS) 0-1370 m (Rear/Front)
MANIFOLD PRESSURE (in. W.c./kpa)
MAN. PRESSURE - LO SETTING (in. W.c./kpa)
MINIMUM INLET PRESSURE (in.w.c./kpa)
MINIMUM INPUT (btu/hr)
MAXIMUM OUTPUT (btu/hr) (CANADA)
36,000
46/46
3.5/0.87
1.2/0.3
5.0/1.24
21,200
29,400
35,000
55/56
10.0/2.48
3.3/0.8
11.0/2.74
20,000
28,900
NATURAL GAS
LP
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
BACK OF STOVE TO BACK WALL
EDGE OF TOP PLATE TO SIDEWALL
EDGE OF TOP PLATE TO DIAGONAL WALL
EDGE OF TOP TO ALCOVE CEILING
2” / 50 mm
4” / 100 mm
3” / 75 mm
14” / 355 mm
BLOWER ASSEMBLY (Part number 95-57010) MAY BE USED
ELECTRICAL RATING: 115 VOLTS, 2.4 AMPS, 60 HZ UL,CSA LISTED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING
UNIT. DO NOT ROUTE POWER CORD UNDER HEATER.
FLOOR PROTECTION (MIN R VALUE 1.1) REQUIRED FROM
MANUFACTURED BY: HearthStone, MORRISVILLE, VERMONT 05661
Date of Manufacture
1999 2000 2001 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
DO NOT REMOVE OR COVER THIS LABEL
MADE IN USA
3300-131
NOT FOR USE WITH SOLID FUEL
THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN
ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE
RATING PLATE AND MAY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY
LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL
CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT
CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A CERTIFIED KIT IS USED.
FRONT OF UNIT TO 16” / 406mm (FROM GLASS)
THIS DIRECT VENT GAS FIREPLACE IS NOT FOR USE WITH AIR FILTERS AND HAS
BEEN SEALED FOR PROPER VENT AIR INTAKE SYSTEM INSTALLATION
CAUTION: DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR
BROKEN. REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR
QUALIFIED SERVICE PERSON.
CAUTIONEER: N’OPERE L’APPAREIL AVEC LE VERRE ENLEVE, CRAQUE OU CASSE.
LE REPLACEMENT DU PANNEAU(S) DEVRAIT ETRE FAIT PAR UNE PERSONNE DE
SERVICE QUALIFIE OU AUTORISE.