MODEL Sterling “G” Direct-Vent
16
3.
#95-60924H: 4"
x
6
e
"
Top Exit Starter Collar Adapter
Used in the following configurations:
-Straight up with vertical termination.
-Straight up with horizontal termination.
-Straight up (vertical) to horizontal with vertical termination.
M
AXIMUM
V
ERTICAL
R
ISE
= 27'
M
INIM UM
V
ERTICAL
R
ISE
= 2'
4. #95-61223HB: 5"
x
8"R
EAR
E
XIT
S
TARTER
C
OLLAR
A
DAPTER
U
SED
O
NLY
W
ITH
T
HE
#95-65000
B
ASIC
V
ENTING
K
IT
;
B
ASIC
V
ENTING
K
IT
I
NSTRUCTIONS ARE INCLUDING WITH THE
K
IT
.
Used in the following configuration:
-Straight back with horizontal
termination.
F
OR
U
SE
O
N
2"
x
4"
OR
2"
x
6"
W
ALLS
M
AX
O
VERALL
T
HICKNESS
= 7½"
Restrictor Plate Installation And Settings
R
ESTRICTION
P
LATE
A vent restrictor plate is available for the appliance to adjust the flow rate of
exhaust gases (draft). In controlling the draft, it also changes the burn and the
aesthetics of the flame. Depending on the vent configuration, you may be required
to adjust the restrictor plate position.
The restrictor plate consists of a rotating shutter below the starter section of pipe
and an adjustment plate with index holes used to hold the shutter in a fixed
position. The restrictor plate has three settings, one (1) being the lowest and three
(3) being the highest. This ensures proper flames for the wide variety of vent
configurations and efficiency. The charts in the venting configurations show if a
restrictor plate is required, and which position the vent restrictor plate must be in. For a fast moving flame with lots of
action use a lower setting. For a slow, lazy flame, a higher setting should be used.
Restictor Plate Setting
Locations
#95-60924
H
#95-61223HB