HearthStone Phoenix 8612 Owner'S Manual Download Page 15

Phoenix Model 8612            

 

Hearthstone Quality Home Heating Products, Inc 

® 

www.hearthstonestoves.com

 

15 

Make sure the size of the chimney’s flue is 
appropriate for this stove, and that it is not too large.  
Use a masonry chimney with an 8" x 8" (203 mm x 
203 mm) maximum tile size for best results.  An 
oversized flue will contribute to the accumulation of 
creosote.   

Use the following checklist to ensure that your 
masonry chimney meets these minimum 
requirements: 

Chimney wall construction: 

 

Brick or modular block at least 4" (102 mm) thick. 

 

A mortared rubble or stone wall. 

 Flue 

liner: 

 

Minimum thickness of 5/8" (16 mm). 

 

Installed with refractory mortar. 

 

At least 1" (25 mm) air space. 

 

An equivalent flue liner must be a listed chimney 
liner system meeting type HT requirements or 
other approved material.  

 Interior 

chimney 

requirements: 

1.  At least 2" (51 mm) clearance to combustible 

structure. 

2.  Fire stops installed at the spaces where the 

chimney passes through floors and/or ceiling. 

3.  2" (51 mm) gap maintained to any insulation   

from the chimney. 

 

Exterior chimney requirements: 
1.  At least 1" (25 mm) clearance to combustible 

structure. 

  Chimney height requirements: (See Figure 

below) 
1.  At least 3 feet (0.9 m) higher than the highest 

part of the roof opening through which it 
passes. 

2.  At least 2 feet (0.6 m) higher than any part of 

the roof within 10 feet (3 m) measured 
horizontally from the top of the chimney.   

This stove requires a minimum chimney height of 13 
feet (4 m).  The maximum allowable chimney height 
is 30 feet (9m). 

 

 

Figure 3 – Chimney Height Requirements

Summary of Contents for Phoenix 8612

Page 1: ...USE YOUR NEW PHOENIX WOOD STOVE To reduce the risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THE...

Page 2: ...Phoenix Model 8612 Hearthstone Quality Home Heating Products Inc www hearthstonestoves com 2 Intentionally Blank...

Page 3: ...ONENTS OF A VENTING SYSTEM 13 INSTALLING A VENTING SYSTEM 13 CONNECTING YOUR WOOD STOVE 14 CONNECTION TO A MASONRY CHIMNEY 14 INSTALLATION IN A MOBILE HOME 17 OPERATION 18 CONTROLS AND FEATURES 18 CHO...

Page 4: ...k of fire Failure to follow these instructions can result in property damage bodily injury and even death Locate your stove in a safe convenient open area away from traffic flow doors and hallways and...

Page 5: ...not installed properly the hearth surface may exceed safe temperatures Follow these safety precautions Never modify this stove in any way especially the primary air control system Never burn kiln drie...

Page 6: ...HIMNEY FIRE BY THROWING WATER ONTO THE STOVE STOVEPIPE OR CHIMNEY THE EXTREMELY HIGH TEMPERATURE ASSOCIATED WITH SUCH FIRES CAN CAUSE INSTANTANEOUS STEAM AND SERIOUS BODILY HARM Once the chimney fire...

Page 7: ...f firebox volume Maximum Log Length 21 53cm Height 27 1 2 70 cm Width 28 71 cm Depth 20 51 cm Front Door Size 16 3 4 wide x 10 5 8 high 43 x 27 cm Stovepipe Size 6 152 mm diameter Metal Chimney 6 152...

Page 8: ...to situate your stove in your particular location Consider both the clearances of the stovepipe and the stove itself to the surrounding combustibles The soapstone walls of the Phoenix soapstone stove...

Page 9: ...the duct from the outside of the house to the hearth keep in mind the need to avoid structural members of the house The outside air kit will attach to the bottom of the stove Before installing the kit...

Page 10: ...e corner 18 46 cm B Wall to pipe 21 54 cm Using Close Clearance Connector Pipe with Rear Heat Shield Residential and Mobile Home Installations for USA Canada Top Exit Parallel Installation A Side wall...

Page 11: ...esidential and Mobile Home Installations for USA Canada Rear Exit Parallel Installation A Side walls to stove 16 41 cm B Back wall to stove 13 33 cm Alcove Installation Using Close Clearance Connector...

Page 12: ...ovides recommended minimum clearances for chimney connectors to combustibles such as walls ceilings and floors Once the stove is installed at safe distances from combustible surfaces it is also import...

Page 13: ...sists of two components the chimney connector and a chimney Both these components become extremely hot during use Temperatures inside the chimney may exceed 2 000 F 1093 degrees C in the event of a cr...

Page 14: ...ype HT 2100 deg F prefabricated metal chimneys listed per UL 103 or ULC S629 standards WARNING DO NOT CONNECT THE STOVE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Ensure the size of the chimney s flu...

Page 15: ...equivalent flue liner must be a listed chimney liner system meeting type HT requirements or other approved material Interior chimney requirements 1 At least 2 51 mm clearance to combustible structure...

Page 16: ...ory house installation w ith attic C him net C ap S to rm C ollar F lashing C him ney S ections C h ase E nclosure W all S trap S upport B ox w ith bu ilt in S tarter A djustable R oof T ee W all T hi...

Page 17: ...N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 two 24 Dura Plus chimney pipes 24 support box with built in starter section and trim UL or ULC...

Page 18: ...shes The back of the ash pan assembly is sloped upwards Before removing the ash pan push it hard into the stove to force the pan up the slope this kicks the ashes further into the pan Do not operate t...

Page 19: ...you understand the controls of your wood stove and have chosen the appropriate firewood you are ready to start a fire CAUTION DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE DO NOT BURN GARBAGE OR FLA...

Page 20: ...rocedure creosote may build up rapidly Your glass may get dirty A good hot fire will clean it We recommend a visual inspection and cleaning if necessary of your stovepipe and chimney once the break in...

Page 21: ...top stones is the best way to determine if the stove is over firing If you suspect that your stove is over firing contact your dealer immediately Damage done by over firing is not covered by your war...

Page 22: ...it promptly to reduce the risk of a chimney fire If your glass remains dirty your stove s operating temperatures are probably consistently lower than normal therefore there is a higher risk of creoso...

Page 23: ...ws in the glass retainer clips Remove the screws to separate the glass from the door 4 Carefully lift the damaged glass from the door and discard 5 Peel the paper backing from the tape gasket Apply th...

Page 24: ...as follows An AIRTIGHT HOUSE If your home is super insulated or especially well sealed the infiltration air supply to the interior of the house can be inadequate This phenomenon of air starvation wit...

Page 25: ...sh pan more frequently UNCONTROLLED OR SHORT BURN Unsealed or Open Door Open ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check the instal...

Page 26: ...17 GRATE FRAME 90 73116 Ash Door Latch Assembly 2610 018 GRATE 96 73121 Front Latch Assembly 26XX 019 BOTTOM CASTING 96 58652 Door Hinge Assembly 26XX 020 REAR PANEL 96 58605 Phoenix Glass Kit 3060 42...

Page 27: ...Phoenix Model 8612 Hearthstone Quality Home Heating Products Inc www hearthstonestoves com 27 Safety Label...

Page 28: ...Phoenix Model 8612 Hearthstone Quality Home Heating Products Inc www hearthstonestoves com 28...

Page 29: ...w hearthstonestoves com or send a completed and signed Warranty Registration Form which is enclosed in the Woodstove warranty packet to the following address Hearthstone Quality Home Heating Products...

Reviews: