Figure 12 – Fireplace Installation Venting Detail
I
NSTALLING
I
N
A
M
OBILE
H
OME
Follow these special requirements for installing your
stove in a mobile home.
•
Install the stove in accordance with 24 CFR,
Part 3280 (HUD)
•
Permanently attach the stove to your mobile
home’s floor. Use 1/4" holes in each leg base to
bolt down the stove.
•
Install one of the following Dura-Vent Mobile
Home Chimney & Connector Kits:
6DP-MH 6” Diameter S/N 9096N
7DP-MH 7” Diameter S/N 9196N
8DP-MH 8” Diameter S/N 9296N
Each kit includes:
Stainless spark arrester cap, storm collar,
Adjustable vented flashing – 0/12 – 6/12,
Two 24” Dura/Plus* chimney pipes, 24”
support box with built-in starter section and
trim.
* (UL or ULC approved equipment is acceptable)
•
EXTERIOR CHIMNEY SECTIONS MUST BE
REMOVED WHEN TRANSPORTING MOBILE
HOME.
•
WARNING: DO NOT INSTALL IN A SLEEPING
ROOM
•
CAUTION:
MAINTAIN THE STRUCTURAL
INTEGRITY OF THE MOBILE HOME WALLS,
FLOOR, CEILING, AND ROOF WHILE YOUR
STOVE IS INSTALLED AND IN USE.
Figure 13
Hearthstone Quality Home Heating Products, Inc.
® Heritage Model 8022
Page 17 of 30