HearthStone Heritage 8022 Owner'S Manual Download Page 15

Chimney Connector Systems and Clearances 
from Combustible Walls for Residential Heating 
Appliances

 

A.  Minimum 3.5in thick brick masonry all 

framed into combustible wall with a 
minimum of 12in. brick separation from clay 
liner to combustibles.  The fire clay liner 
shall run from outer surface of brick wall to, 
but not beyond, the inner surface of chimney 
flue liner and shall be firmly cemented in 
place. 

B.  Solid-insulated, listed factory-built chimney 

length of the same inside diameter as the 
chimney connector and having 1in. or more 
of insulation with a minimum 9in. air space 
between the outer wall of the chimney length 
and combustibles. 

C.  Sheet steel chimney connector, minimum 24 

gauge in thickness, with a ventilated thimble, 
minimum 24 gauge in thickness, having two 
1in. air channels, separated from 
combustibles by a minimum of 6in of glass 
fiber insulation. Opening shall be covered, 
and thimble supported with a sheet steel 
support, minimum 24 gauge in thickness. 

D.  Solid insulated, listed factory-built chimney 

length with an inside diameter 2in. larger 
than the chimney connector and having 1in. 
or more of insulation, serving as a pass-
through for a single wall sheet steel chimney 
connector of minimum 24 gauge thickness, 
with a minimum 2in. air space between the 
outer wall of chimney section and 
combustibles.  Minimum length of chimney 
section shall be 12in. chimney section 
spaced 1in. away from connector using 
sheet steel support plates on both ends of 
chimney section. Opening shall be covered, 
and chimney section supported on both 
sides with sheet steel supports securely 
fastened to wall surfaces of minimum 24 
gauge thickness.  Fasteners used to secure 
chimney section shall not penetrate chimney 
flue liner.

 

 

Hearthstone Quality Home Heating Products, Inc. 

®                                                                                                                                                                     Heritage Model 8022 

 

 Page 15 of 30 

Summary of Contents for Heritage 8022

Page 1: ...e risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CONTACT...

Page 2: ...Intentionally Blank Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 2 of 30...

Page 3: ...SYSTEM 12 INSTALLING A VENTING SYSTEM 12 CONNECTING YOUR WOOD STOVE 13 INSTALLING IN A MOBILE HOME 17 OPERATION 18 CONTROLS AND FEATURES 18 CHOOSING FIREWOOD 19 WOOD HEAT VALUE 19 BUILDING A FIRE 20...

Page 4: ...n death Locate your stove in a safe convenient open area away from traffic flow doors and hallways and near a chimney and chimney connector Review the proper clearance measurements from combustible su...

Page 5: ...himney connector and chimney as recommended Follow these safety precautions Never modify this stove in any way especially the primary air control system Never burn kiln dried wood painted or treated w...

Page 6: ...is new technology will not corrode rust dissolve or lose its strength however it is vulnerable to puncture or cracking due to rough handling PLEASE EXERCISE CARE WHEN LOADING WOOD OR CLEANING YOUR STO...

Page 7: ...wide x 11 high 46 x 28 cm Side Door Size 10 5 wide x 8 5 high 31 8 x 21 6 cm Stovepipe Size 6 152 mm diameter Metal Chimney 6 152 mm inside diameter Masonry Chimney 6 15 2cm inside diameter round flu...

Page 8: ...fic to the Simpson Dura Vent DVL brand Clearances cannot be reduced without the use of close clearance connector pipe and or by protecting the surfaces per NFPA 211 standards Locate the stove centrall...

Page 9: ...rticularly air tight house The outside air kit for this stove allows for the direct connection of the stove s air intake to a minimum 3 76 mm diameter duct supplied by others which leads to the outsid...

Page 10: ...es inches Unprotected Surfaces Protected Surfaces NFPA 211 Minimum alcove width 61 49 Maximum alcove depth 48 48 Alcove ceiling above stove top 57 24 If you use a rear heat shield to obtain reduced cl...

Page 11: ...Figure 9 Mantle Clearances Side View Figure 8 Mantle Clearances Front View Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 11 of 30...

Page 12: ...bustibles discussed earlier to install your stove safely To protect against the possibility of a house fire you must properly install and constantly maintain the venting system Upon inspection immedia...

Page 13: ...6 152 mm inside diameter flue for new installations A 6 diameter flue provides adequate draft and performance You can use an 8 203 mm diameter existing flue with a reducer An oversized flue contribute...

Page 14: ...d chimney liner system meeting type HT requirements or other approved material Interior chimney requirements At least 2 51 mm clearance to combustible structure Fire stops must be installed at the spa...

Page 15: ...rom combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Solid insulated listed factory...

Page 16: ...Figure 11 Typical Venting Configurations Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 16 of 30...

Page 17: ...96N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support b...

Page 18: ...andle is located on the front lower left of the stove just under the ash lip The primary air control allows you to regulate the amount of air entering the firebox Generally the more air allowed into t...

Page 19: ...igh Beech European 3 757 24 Maple Sugar 3 757 24 Oak Red 3 757 24 Ash White 3 689 23 6 Birch Yellow 3 689 23 6 Medium Juniper Rocky Mtn 3 150 21 8 Elm Red 3 112 21 6 Coffeetree Kentucky 3 112 21 6 Hac...

Page 20: ...odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere to the followi...

Page 21: ...m the glass in front in order for the air wash system to work properly Keep the front door and ash door closed while the stove is in use 6 Once the fire is burning well use the primary air control to...

Page 22: ...sposing of ashes Ashes may be removed from the firebox with an ash shovel and placed into a suitable container The optional ash pan and ash pan access door are located under the ash lip The ash pan co...

Page 23: ...heck the chimney at the top where it is coolest as well as from the bottom near the stove Accumulated creosote should be removed with a cleaning brush specifically designed for the type of chimney in...

Page 24: ...et Apply the new gasket to the doorframe as illustrated 6 Place the gasketed glass onto the door Place a new clips and gasket squares around the glass and over the screw holes in the clip 7 Screw the...

Page 25: ...s been used Such changes are normal and do not affect the operation or the integrity of the stove and do not require replacement If you observe a completely broken stone contact your dealer for servic...

Page 26: ...our home is super insulated or especially well sealed the infiltration air supply to the interior of the house may be inadequate This phenomenon of air starvation within the building can be exacerbate...

Page 27: ...ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check the installation Operate at LOW BURN Install stovepipe damper Deteriorated Cement Seal...

Page 28: ...CONTROL HER1 TRI 2010 282 PLATE FLUE HER 1 MCR CAS MISC 2010 285 COLLAR FLUE MATTE HER 1 TRI MCR CAS 6400 40490 OWNER S MANUAL 2010 287 PLENUM SEC AIR BOT HER2 90 58210 COMPLETE GASKET KIT 2010 289 P...

Page 29: ...Safety Rating Label Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 29 of 30...

Page 30: ...urces warranty registration Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Avenue Morrisville VT 05661 NOTE COMPLETING THE WARRANTY REGISTRATION FORM IS NOT REQUIRED AS...