HearthStone Heritage 8022 Owner'S Manual Download Page 12

Venting Components and Configuration 

CONVERTING TO REAR VENT

 

In order to convert the Heritage from a top to rear or 
vice-versa, reach through the flue collar and 
remove the four ¼-20 hex head screws that mount 
the cover plate. Next, reach through the hole where 
the cover plate was and remove the four ¼-20 hex 
head screws that mount the flue collar. Exchange 
the two pieces and reattach the eight screws.

 

DO NOT CONNECT THIS UNIT TO A CHIMNEY 
FLUE SERVING ANOTHER APPLIANCE 

 

Single wall connector is 24 MSG or 25 MSG 
blued steel stovepipe. 

 

Double wall connector (close clearance pipe) 
which must be used with a listed factory-built 
“Type HT" chimney also may be used with a 
masonry chimney to reduce clearances, is 
available from several manufacturers, your 
dealer can help you choose.  Some air 
insulated connector pipe models available are 
Simpson Dura Vent DVL and Metalbestos DS. 
Security, GSW and Ameritec also have 
acceptable close clearance connector pipe. 

 

When used in a mobile home, a spark arrester 
is required. (See page 17) 

 

Chimney connector shall not pass through floor 
or ceiling, nor any attic or roof space, closet or 
similar concealed space.  Where passage 
through a wall or partition of combustible 
construction is desired, the installation shall 
conform to NFPA 211 or CAN/CSA - B365. 

It is very important to follow minimum clearances for 
chimney connectors to combustibles such as walls 
and ceilings when installing the stove near non-
combustible surfaces.  Typical chimney connector 
clearances are outlined below.  The single wall 
clearances are generic; the Double wall clearances 
are for Simpson Dura Vent DVL. 

 

 

ALWAYS CHECK THE CLEARANCE SPECIFICATIONS 
FROM THE MANUFACTURER OF YOUR CONNECTOR 
PIPE 

 

DO NOT CONNECT THE VENT TO ANY AIR 
DISTRIBUTION DUCT OR AIR HANDLING SYSTEM. 

C

OMPONENTS OF A 

V

ENTING 

S

YSTEM

 

The complete venting system consists of several 
components:  chimney connector, wall thimble, wall 
pass-through, chimney, and liner.  It is 

absolutely 

necessary

  that you install all of these components 

within the clearances to combustibles discussed 
earlier to install your stove safely. 

To protect against the possibility of a house fire, you 

must properly install and constantly maintain the 
venting system

.  Upon inspection, immediately 

replace rusted, cracked, or broken components.   

 

The 

chimney connector

 is the stovepipe from the 

woodstove to the chimney.  The chimney 
connector stovepipe must be 6" (152 mm) 
diameter, 24 MSG or 25 MSG blued steel 
connector pipe.  

Do not use aluminum or 

galvanized steel pipe

 - they cannot withstand the 

extreme temperatures of a wood fire. 

 

thimble

 is a manufactured (or site-constructed) 

device installed in combustible walls through 
which the chimney connector passes to the 
chimney. It keeps the walls from igniting.  You 
must use a wall thimble when installing a 
chimney connector through a combustible wall to 
the chimney.   

 

wall pass-through

  (or chimney support 

package) also keeps the walls from igniting.  You 
must use one when connecting through a wall or 
ceiling to a prefabricated chimney.   

 

Only install this stove to a 

lined masonry chimney

 

or an approved high temperature 

prefabricated 

residential

  type building heating appliance 

chimney.  

Do not

 connect this stove to a chimney 

serving another appliance; you will compromise 
the safe operation of both the wood stove and 
the connected appliance.   

 

WARNING:  DO NOT CONNECT THIS APPLIANCE 
TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. 

 

liner

  is the UL 1777 or ULC S635 (for factory 

built fireplace or masonry) chimney. 

You must connect your stove to a chimney 
comparable to those recommended in this manual.  

Do not use stovepipe as a chimney

.  Use stovepipe 

for freestanding installations only to connect the 
stove to a proper chimney. 

I

NSTALLING A 

V

ENTING 

S

YSTEM

 

Stovepipe sections must be attached to the stove and 
to each other with the crimped end toward the stove.  
If creosote builds up, this allows the creosote to run 
into the stove and not the outside of the stovepipe 
and onto the stove. 

Secure all joints, including attaching the stovepipe to 
the stove's flue collar, with three sheet metal screws.  
Install #10 x 1/2" (3 mm x 13 mm) sheet metal screws 
into the holes pre-drilled in the flue collar.  Leaving off 

Hearthstone Quality Home Heating Products, Inc. 

®                                                                                                                                                                     Heritage Model 8022 

 

 Page 12 of 30 

Summary of Contents for Heritage 8022

Page 1: ...e risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CONTACT...

Page 2: ...Intentionally Blank Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 2 of 30...

Page 3: ...SYSTEM 12 INSTALLING A VENTING SYSTEM 12 CONNECTING YOUR WOOD STOVE 13 INSTALLING IN A MOBILE HOME 17 OPERATION 18 CONTROLS AND FEATURES 18 CHOOSING FIREWOOD 19 WOOD HEAT VALUE 19 BUILDING A FIRE 20...

Page 4: ...n death Locate your stove in a safe convenient open area away from traffic flow doors and hallways and near a chimney and chimney connector Review the proper clearance measurements from combustible su...

Page 5: ...himney connector and chimney as recommended Follow these safety precautions Never modify this stove in any way especially the primary air control system Never burn kiln dried wood painted or treated w...

Page 6: ...is new technology will not corrode rust dissolve or lose its strength however it is vulnerable to puncture or cracking due to rough handling PLEASE EXERCISE CARE WHEN LOADING WOOD OR CLEANING YOUR STO...

Page 7: ...wide x 11 high 46 x 28 cm Side Door Size 10 5 wide x 8 5 high 31 8 x 21 6 cm Stovepipe Size 6 152 mm diameter Metal Chimney 6 152 mm inside diameter Masonry Chimney 6 15 2cm inside diameter round flu...

Page 8: ...fic to the Simpson Dura Vent DVL brand Clearances cannot be reduced without the use of close clearance connector pipe and or by protecting the surfaces per NFPA 211 standards Locate the stove centrall...

Page 9: ...rticularly air tight house The outside air kit for this stove allows for the direct connection of the stove s air intake to a minimum 3 76 mm diameter duct supplied by others which leads to the outsid...

Page 10: ...es inches Unprotected Surfaces Protected Surfaces NFPA 211 Minimum alcove width 61 49 Maximum alcove depth 48 48 Alcove ceiling above stove top 57 24 If you use a rear heat shield to obtain reduced cl...

Page 11: ...Figure 9 Mantle Clearances Side View Figure 8 Mantle Clearances Front View Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 11 of 30...

Page 12: ...bustibles discussed earlier to install your stove safely To protect against the possibility of a house fire you must properly install and constantly maintain the venting system Upon inspection immedia...

Page 13: ...6 152 mm inside diameter flue for new installations A 6 diameter flue provides adequate draft and performance You can use an 8 203 mm diameter existing flue with a reducer An oversized flue contribute...

Page 14: ...d chimney liner system meeting type HT requirements or other approved material Interior chimney requirements At least 2 51 mm clearance to combustible structure Fire stops must be installed at the spa...

Page 15: ...rom combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Solid insulated listed factory...

Page 16: ...Figure 11 Typical Venting Configurations Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 16 of 30...

Page 17: ...96N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support b...

Page 18: ...andle is located on the front lower left of the stove just under the ash lip The primary air control allows you to regulate the amount of air entering the firebox Generally the more air allowed into t...

Page 19: ...igh Beech European 3 757 24 Maple Sugar 3 757 24 Oak Red 3 757 24 Ash White 3 689 23 6 Birch Yellow 3 689 23 6 Medium Juniper Rocky Mtn 3 150 21 8 Elm Red 3 112 21 6 Coffeetree Kentucky 3 112 21 6 Hac...

Page 20: ...odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere to the followi...

Page 21: ...m the glass in front in order for the air wash system to work properly Keep the front door and ash door closed while the stove is in use 6 Once the fire is burning well use the primary air control to...

Page 22: ...sposing of ashes Ashes may be removed from the firebox with an ash shovel and placed into a suitable container The optional ash pan and ash pan access door are located under the ash lip The ash pan co...

Page 23: ...heck the chimney at the top where it is coolest as well as from the bottom near the stove Accumulated creosote should be removed with a cleaning brush specifically designed for the type of chimney in...

Page 24: ...et Apply the new gasket to the doorframe as illustrated 6 Place the gasketed glass onto the door Place a new clips and gasket squares around the glass and over the screw holes in the clip 7 Screw the...

Page 25: ...s been used Such changes are normal and do not affect the operation or the integrity of the stove and do not require replacement If you observe a completely broken stone contact your dealer for servic...

Page 26: ...our home is super insulated or especially well sealed the infiltration air supply to the interior of the house may be inadequate This phenomenon of air starvation within the building can be exacerbate...

Page 27: ...ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check the installation Operate at LOW BURN Install stovepipe damper Deteriorated Cement Seal...

Page 28: ...CONTROL HER1 TRI 2010 282 PLATE FLUE HER 1 MCR CAS MISC 2010 285 COLLAR FLUE MATTE HER 1 TRI MCR CAS 6400 40490 OWNER S MANUAL 2010 287 PLENUM SEC AIR BOT HER2 90 58210 COMPLETE GASKET KIT 2010 289 P...

Page 29: ...Safety Rating Label Hearthstone Quality Home Heating Products Inc Heritage Model 8022 Page 29 of 30...

Page 30: ...urces warranty registration Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Avenue Morrisville VT 05661 NOTE COMPLETING THE WARRANTY REGISTRATION FORM IS NOT REQUIRED AS...

Reviews: