Venting Information
Venting Components
Use the following instructions along with the pipe
manufacturer’s instructions to complete the
installation. Do not mix vent components from
different manufacturers within the same venting
system.
Approved Venting Manufacturers
The DVI 44 Direct Vent (8860) is approved for
installation only with the venting components
provided by manufactures listed on
this page.
M&G Dura-Vent, Inc.
920 Aldridge Road
Vacaville, CA 95688
800-835-4429
American Metal Products
(AmeriVent)
8601 Hacks Cross Rd.
Olive Branch, MS 38654
800-423-4270
Selkirk Corporation
1301 W. President George Bush Hwy, Suite 330
Richardson, TX 75080-1139
800-992-8368
Security Chimneys International Ltd
(Secure Vent)
2125 Monterey, Laval, Quebec
Canada, H7L 3T6
450-973-9999
ICC, Inc.
400 J-F Kennedy, St. Jerome, Quebec
Canada, J7Y 4B7
450-565-6336
Metal-Fab, Inc.
P.O. Box 1138
Wichita, Kansas 67201
316-943-2351
Venting Terminations
The DVI 44 cannot be vented jointly with any other
solid fuel or gas appliance. It must be vented
vertically directly to the outside of the building using
a proper termination as listed in this manual. After
determining the venting configuration for your stove,
select the vent system that will best accommodate
your installation.
CAUTION:
ENSURE
ALL
APPLIANCE
AND
TERMINATION
CAP
CLEARANCES
ARE
OBSERVED
PER THIS OWNER’S MANUAL.
CAUTION: ENSURE THERE IS NO WIRING OR
PLUMBING IN THE CHOSEN LOCATION.
CAUTION:
DO
NOT
RECESS
VENTING
TERMINALS INTO A WALL OR SIDING.
Approved Venting Configurations
WARNING:
IN
HIGH
WIND
AREAS
AND
PARTICULARLY COLD CLIMATES IT MAY BE
NECESSARY TO HEAT YOUR VENT SYSTEM
WITH THE PILOT PRIOR TO IGNITION OF THE
MAIN BURNER. IN THESE INSTANCES IT IS
RECOMMENDED THAT YOU LEAVE THE PILOT
RUNNING FOR 5 MINUTES PRIOR TO IGNITING
THE MAIN BURNER. THIS WILL ALLOW FOR
PROPER START UP AND IGNITION OF ALL
PORTS ON THE BURNER.
Note: There is only one type of venting
configuration approved for use with this
appliance:
Vertical Venting/Vertical Termination
Vertical Venting and Termination
The DVI 44 8860 is approved only for venting
vertically through an existing chimney, a roof, or
ceiling. When installing a vertical vent and/or vertical
termination you must adhere to the following
requirements:
When terminating vertically you must have at
least 10’ of vertical pipe.
Steep roofs, nearby trees, or predominantly
strong windy conditions can promote poor draft
or down draft conditions. In this event, an
increase to the height of the vent may improve
performance.
All termination caps must be no less than 18”
(457mm) horizontally from any roof or vertical
surface. See page 233.
The maximum vertical run is 35’
The minim
um vertical run is 10’
The vent/air intake termination clearances above the
high side of an angled roof are as follows:
Roof Pitch
Feet
Meters
Flat to 6/12
1
0.3
7/12 to 9/12
2
0.6
10/12 to 12/12
4
1.2
13/12 to 16/12
6
1.8
17/12 to 21/12
8
2.4