VS0952_E
12/30/2009
29
NOTE:
To
operate
in
either
of
the
two
thermostat
modes,
an
optional
thermostat
kit
must
be
purchased
and
installed.
Thermostats
compatible
with
your
Hearthland
stove
are
available
from
your
local
dealer.
Thermostat
Modulated
Mode
has
advantages
over
Thermostat
ON/OFF
mode.
⇒
More
consistent
room
temperature
will
be
maintained.
⇒
Life
of
the
Auto
Igniter
is
increased,
seeing
fewer
ignition
cycles.
⇒
The
stove
will
tend
to
operate
primarily
at
the
low
setting,
resulting
in
more
efficient
use
of
energy
to
maintain
desired
temperature
setting.
O
PERATING
I
NSTRUCTIONS
(C
(C
ONTINUED
ONTINUED
)
)
THERMOSTAT
ON
‐
OFF
MODE
In
this
mode
the
thermostat
is
set
at
the
desired
room
temperature.
If
the
room
temperature
drops
below
the
level
on
the
thermostat
the
stove
will
automatically
light
and
operate
at
HEAT
LEVEL
setting
2,3
or
4
until
the
temperature
setting
is
reached
at
which
time
the
stove
will
shut
down.
TO
START
⇒
Press
START
to
activate
the
stove
per
section
#4.7
“Starting
Stove
&
Shutting
Off
Stove”.
⇒
Select
desired
HIGH
heat
output
level
(2,3
or
4
position)
by
pressing
the
START
/
HEAT
LEVEL
touch
pad.
NOTE:
The
Heat
Level
can
be
adjusted
between
setting
2
‐
4
at
any
time.
⇒
Select
desired
FAN
SPEED
setting
as
described
in
section
#4.8
“Setting
Fan
Speed”.
TO
SHUT
DOWN
⇒
To
turn
off
the
appliance
press
the
OFF
touch
pad
per
section
#4.7
“Starting
Stove
&
Shutting
Off
Stove”.
Note:
If
in
THERMOSTAT
ON
‐
OFF
MODE
the
stove
turns
off
and
on
frequently,
we
suggest
you
turn
the
HEAT
LEVEL
to
a
lower
setting
so
that
it
stays
on
for
longer
periods.
This
will
result
in
a
more
consistent
room
tempera
‐
ture.
THERMOSTAT
MODULATED
MODE
(HIGH
‐
LOW)
This
feature
of
your
stove
allows
for
modulated
heating
with
use
of
a
thermostat
connected
to
the
ITC.
In
this
mode
your
stove
will
run
at
the
heat
setting
2,3
or
4
when
the
thermostat
calls
for
more
heat,
and
drop
to
heat
setting
1
when
the
set
room
temperature
is
achieved.
This
makes
your
stove
more
responsive
to
your
heating
needs,
and
eliminates
the
need
to
re
‐
ignite
with
each
heat
demand
cycle.
TO
START
⇒
To
operate
in
High
Low
thermostat
mode,
press
the
START
touch
pad
to
activate
the
stove
as
described
in
section
#4.7
“Starting
Stove
&
Shutting
Off
Stove”.
⇒
Select
desired
HIGH
heat
output
level
(2,3
or
4
position)
by
pressing
the
START
/
HEAT
LEVEL
touch
pad.
⇒
Select
desired
FAN
SPEED
setting
as
described
in
section
#4.8
“Setting
Fan
Speed”.
⇒
Once
settings
are
selected
your
high
HEAT
LEVEL
and
FAN
SPEED
LED’s
will
flash
while
your
stove
goes
through
the
initial
start
up
cycle.
⇒
Upon
completion
of
startup
cycle,
the
stove
will
cycle
between
HEAT
LEVEL
1
and
the
high
setting
selected
(2,3
or
4
position)
the
HEAT
LEVEL
indicator
light
will
light
indicating
its
current
setting.
TO
SHUT
DOWN
⇒
To
turn
off
the
appliance
press
the
OFF
touch
pad
per
section
#4.7
“Starting
Stove
&
Shutting
Off
Stove”.
Summary of Contents for Hiawatha
Page 13: ...VS0952_E 12 30 2009 13 EXHAUST SYSTEM CONTINUED PELLET VENT TERMINATION...
Page 41: ...VS0952_E 12 30 2009 41 REPLACEMENT PARTS LIST...
Page 42: ...VS0952_E 12 30 2009 42 REPLACEMENT PARTS LIST CONTINUED...
Page 43: ...VS0952_E 12 30 2009 43 REPLACEMENT PARTS LIST CONTINUED...
Page 44: ...VS0952_E 12 30 2009 44 REPLACEMENT PARTS LIST CONTINUED...
Page 45: ...VS0952_E 12 30 2009 45 REPLACEMENT PARTS LIST CONTINUED...
Page 46: ...VS0952_E 12 30 2009 46 REPLACEMENT PARTS LIST CONTINUED...
Page 47: ...VS0952_E 12 30 2009 47 REPLACEMENT PARTS LIST CONTINUED...
Page 48: ...VS0952_E 12 30 2009 48 REPLACEMENT PARTS LIST CONTINUED...