
16
FLUEING WITH THREE (3) 90° ELBOWS
V
H
H + H
1
FT. (M)
FT. (M)
FT. (M)
1' MIN.(.3M)
2' MAX.(.6M)
4' MAX.(1.2M)
2' MIN.(.6M)
4' MAX.(1.2M)
8' MAX.(2.4M)
3' MIN.(.9M)
6' MAX.(1.9M)
10' MAX.(3.0M)
4' MIN.(1.2M)
6' MAX.(1.9M)
12' MAX.(3.6M)
V+V
1
= 22' MAX (6.7M) 6' MAX (1.9M) 12' MAX (3.6M)
FLUEING WITH THREE (3) 90° ELBOWS
FIGURE 14
V
H + H1
FT. (M)
FT. (M)
1'MIN.(.3M)
2' MAX.(.6M)
2'MIN.(.6M)
4' MAX.(1.2M)
3'MIN.(.9M)
6' MAX.(1.8M)
4'MIN.(1.2M)
8' MAX.(2.5M)
5'MIN.(1.5M)
10' MAX.(3.0M)
10' MAX.(3.0M)
NOTE: V + V
1
MAX. 20'(6.1M)
USE SL D-SERIES COMPONENTS ONLY.
V
1
H
1
H
V
H
1
H
V
1
V