4
Figure 1. Diagram of the 6000 Series
1.0 INSTALLATION INSTRUCTIONS
When planning a heater installation, its
necessary to determine:
Where the unit is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical wiring.
Framing and finishing details.
Whether optional accessoriesdevices such
as a fan, wall switch, or remote controlare
desired.
If the heater is to be installed on carpeting or tile,
or on any combustible material other than wood
flooring, the heater should be installed on a metal
or wood panel that extends the full width and depth
of the heater.
36 (914mm)
41 (1040mm)
8 1/4
(210mm)
3 1/2
(89MM)
7 (178MM)
ELECTRICAL
ACCESS
26 1/2 (672MM)
13 1/4 (337MM)
21 1/2 (546MM)
17 1/2
(445mm)
9 1/4
(235mm)
7 1/4 (184mm)
2 1/2
(63mm)
GAS LINE
ACCESS
21 (533mm)
38
(965mm)
35
(889mm)
11 5/8
(293mm)
HI-TEMP.
LIMIT
SWITCH
ELECTRICAL
ACCESS
GAS LINE
ACCESS
STANDOFFS
GAS CONTROLS
AND SWITCHES
DATA BADGE
/LABELS
GLASS
DOOR
TOP
STANDOFFS