17
FIGURE 19
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
105
C RATED WIRE.
FIGURE 20
1.5.1 INSTALLING THE ELECTRICAL
SERVICE TO THE JUNCTION BOX
WARNING:
TURN ELECTRICAL POWER OFF AT
THE CIRCUIT BREAKER BEFORE BEGINNING IN-
STALLATION.
1. Remove the electrical cover plate from the lower side
of the heater. Remove the knockout from the plate
and attach the Romex clamp (screws to the out-
side.)
2. Feed the electrical services wires through the Romex
clamp and secure the wire to the clamp.
3. Using the wire connector provided inside the junc-
tion box, attach the neutral service wire to the blue
wire, the hot service wire to the black wire, and the
service ground wire to the ground screw stud of the
junction box. See Figure 20 for wire connection de-
tail and Figure 19 for a complete wiring diagram.
4. Re-attach the cover plate to the outside of the heater.
WARNING:
DO NOT CONNECT 220 VAC TO THE
GAS CONTROL VALVE OR CONTROL WIRING SYS-
TEM OF THIS MODEL.
JUNCTION BOX
FAN
BLUE
BROWN
YELLOW/GREEN
BLUE
BRN
YW/GR
BLK
BLK
TEMP. SENSOR
SWITCH
BLK
BLK
SPEED CONTROL
FAN WIRING DIAGRAM
BLK
BLK
YELLOW/GRN
YELLOW/GRN
BLUE
BRN
BR
N
BL
U
E
GRD
BL
U
E
JUNCTION BOX DETAIL
FAN
TEMPERATURE
SENSOR SWITCH
FAN SPEED
CONTROL
JUNCTION BOX
NEUTRAL (BLUE)
BLUE
HOT (BROWN)
BROWN
BLACK
BLACK