Operation

The SMART-WALL-B uses a control module that must be used with the IntelliFire™ Touch control system. The SMART-

WALL-B blower turns on and operates for two minutes before the ignition sequence begins. The SMART-WALL-B blower will 
remain on for 20 minutes after the appliance is turned off to remove residual heat so the TV does not overheat.

Figure 14. Good Faith Guidelines for TV Installation

Maintenance

Service and maintain the gas appliance per instructions.  

Keep the air register clean and free of any blockage.

60 inches

1. Each of the clearances described above are the minimum required in order to maintain your TV’s operating temperature    

within the manufacturer’s specified maximum operating temperature when operating the fireplace appliance, Smart-Wall Air 

Duct Kit and your TV within a room with an ambient temperature of not more than 75 degrees Fahrenheit.  

2.  Since every home has unique air flow characteristics and maximum allowable operating temperatures can vary from 

manufacturer to manufaturer and from model to model, actual TV temperatures should be validated at the time of each 

installation.  TVs should not be used in stituations where the actual TV temperature exceeds the manufacturers’ maximum 

allowable operating temperatures identified in the TV’s technical specifications.  If the maximum allowable operating 

temperature for TV is less than 100 degrees Fahrenheit you should not use your TV with this application as damage to your TV 

may occur.  Contact the TV’s manufacturer directly if you cannot locate this information or have questions regarding this 

information.

3.  “A” dimension taken from the top of the appliance opening to the bottom of the TV.

4.  “B” dimension taken from back of the TV to the wall behind the TV.  This 3” minimum air gap must be maintained and not 

blocked with any object. 

5.  “C” dimension taken from top of appliance opening to ceiling. 

Good Faith Guidelines for TV Installation above an approved appliance with a Smart-Wall 

installed.  See page 1 for list of approved appliances.

TV mounted flat

TV mounted at angle

TV Wall Bracket

Appliance

Appliance

Minimum 

clearance from 

fireplace 

opening to 

sidewall - 24 in.

C

C

C

3

Summary of Contents for SMART WALL B

Page 1: ...aged contact your Dealer before starting installation DO NOT install a damaged kit Be sure to also reference the appliance Installers Guide Preliminary Preparation Contents of kit Please note while th...

Page 2: ...mum of two feet horizontally from TV unless register is mounted at least 12 inches above the TV Clearance from insulated flexible duct to combustibles 0 inches MODELS COSMO32 IFT COSMO42 IFT RAVE3012...

Page 3: ...e 2 Note A minimum clearance of 18 inches to any com bustible materials or combustible surfaces such as room furnishings furniture curtains etc is required from the fan housing air outlet Plan for thi...

Page 4: ...cal electric codes CAUTION Risk of shock Disconnect electrical power from fireplace power vent before performing any mainte nance repair or electrical wiring NOTICE Electrical service of 120 VAC 60Hz...

Page 5: ...ROL RF MODULE I S BRN ORANGE PILOT IFT RC400 REMOTE CONTROL GRN WHT BLK RED BLK IFT RC150 WIRELESS WALL SWITCH OPTIONAL SPLITTER BLK RED ADAPTER 6V DC BATTERY PACK BLK RED 6 PIN BLK RED GREEN MAIN RED...

Page 6: ...pproved options including lights and SMART WALL B To connect a light kit to the IFT ACM remove pro tective rubber cap labeled LIGHTS and connect to the female cord that was supplied in your lights kit...

Page 7: ...wire from the IFT ECM wire harness to the white wire coming from the SMART WALL B control module 13 Connect the male DC jack connector from the power harness 2326 136 to the female DC jack connector...

Page 8: ...T connect SMART WALL B module to IFT ACM Disconnect 6V power to lock out appliance Failure to follow instructions could result in damage to the TV WARNING BRN FLAME SENSE IGNITER TO JUNCTION BOX 110 1...

Page 9: ...LTM Control Module to IFT ECM wire harness brown wire 3 PIN FEMALE CONNECTOR Connect 3 Pin Female Connector from SMART WALLTM Control Module to IFT ACM AUX port ACCESSORY CABLE BRN BLK GREEN MAIN WHT...

Page 10: ...le the green LED on the IFT ECM is blinking tap anywhere on the gray indicator bar located at the top of the IFT RC400screen Taponthepairingfunctionasshownin Figure 13 If the IFT RC400 has been paired...

Page 11: ...e IFT RC400 IFT RC400 1 Touch screen on RC400 to wake up 2 Touch Turn Flame On 3 Observe touch screen if system is configured properly for SMART WALL B Operation a 2 minute countdown timer will be dis...

Page 12: ...ith an ambient temperature of not more than 75 degrees Fahrenheit 2 Since every home has unique air flow characteristics and maximum allowable operating temperatures can vary from manufacturer to manu...

Reviews: