Hearth & Home Technologies • SMART-WALL-B Air Duct Kit • 4086-348 Rev. D • 3/20
10
Pairing or Re-Pairing the IFT-RC400 to the
Electronic Control Module (IFT-ECM)
WARNING!
After installation of SMART-WALL-B compo
-
nents, the RC400 and IFT-ECM
MUST BE
re-paired to
detect the SMART-WALL-B accessories.
CAUTION! Risk of Burns!
DO NOT program the IFT
Remote Controls to the IFT-ECM when flame or cold
climate function is on or when appliance is hot.
1. On the IFT-ECM, move the ON/OFF/REMOTE switch to
the REMOTE position. The green LED will blink three
times. A few seconds later, an audible “beep” will occur
to indicate that the system is ready.
Note:
If the green LED continues to blink slowly (system
is searching for a clear channel), wait until it stops before
proceeding to step 2.
2. Locate the pairing hole on the IFT-ECM. See Figure 12.
Using a paper clip or similar item, press and release
the pairing button. The IFT-ECM will “beep” once
and the green LED will blink for 14 seconds. During
the 14 seconds, it is normal for installed accessories
such as lights, fan, and SMART-WALL-B to energize
momentarily.
While the green LED on the IFT-ECM is blinking, tap
anywhere on the gray indicator bar located at the top of the
IFT-RC400 screen. Tap on the pairing function as shown in
Figure 13. If the IFT-RC400 has been paired successfully
to the IFT-ECM, a double audible ‘beep” will be heard from
the IFT-ECM.
Note:
If the RC400 displays the 'Now pairing remote to
product' display as shown below
before
able to reach the
diagnostic menu on remote, you must repeat the process
as follows;
A. Remove one battery from the RC400.
B. Press the pairing button on the IFT-ECM.
C. Quickly install the battery into the RC400.
D. As soon as the main screen appears, tap on the
RC400 gray indicator bar. Then immediately tap the
pairing icon. Successful pairing will be indicated by a
double beep from the IFT-ECM.
3. If the pairing is unsuccessful, repeat steps 1 & 2.
Figure 12. Pairing IFT-ECM
REMOTE POSITION
REMOTE POSITION
PAIRING HOLE
PAIRING HOLE
GREEN LED
GREEN LED
Figure 13. IFT-RC400 Wall Mount / Pairing Screen
NOTE:
Refer to Operating Guide and Troubleshoot-
ing Section of IFT-RC400 Installation Manual for
Operation and Maintenance Sections of Remote
Control.
Note:
If additional components are added such
as lights or SMART-WALL-B after initial
pairing, the pairing process must be repeated
again to detect additional components.