Hearth & Home Technologies  •  SMART-WALL-B Air Duct Kit  •  4086-348 Rev. D  •  3/20

The purpose of this kit is to keep the area above the appli-

ance at a temperature that is within the flat screen style TV 

manufacturer’s specified maximum operating temperature.   
The ability of the 

SMART-WALL-B 

TV Kit to accomplish 

this purpose is expressly dependent upon the following 

conditions.   

• 

The manufacturer’s specified maximum operating tem

-

perature (for the TV unit being used in this application) 

being no less than 100 degrees Fahrenheit (consult 

your manufacturer to determine the maximum operating 

temperature for your TV unit); 

If the specified maximum operating temperature  

 

for your TV unit is less than 100 degrees Fahren-            

heit, do not use that particular TV in this application.

• 

The back of the TV unit (after installation on a wall 

mounted bracket) having and maintaining not less than 

a 3-inch gap between the back of the TV unit and the 

wall.  This is the gap between the back of the TV and 

the wall which is vital for proper air and temperature 

circulation.

• 

The ambient temperature of the room is maintained at 

75 degrees Fahrenheit or less. 

•  The SMART-WALL-B 

TV Kit and the TV must be installed 

and operated in strict compliance with all other appli

-

cable installation and operation instructions for this kit.  

SMART-WALL-B TV Kit

- Installation & Operation Instructions -

DESCRIPTION

SERVICE PART NO.

20 ft. Length of 6 in. Insulated 

Round Duct

659-200

Fan Housing Assembly

659-001A

Junction Box

659-122

SMART-WALL-B Control Module

2326-180

Air Register

659-150

Register Adaptor Frame-Thick

SRV695-125

Appliance Duct Collar

SRV659-125

Duct Adaptor (Round to Oval)

659-129

Accessory Cable (20 ft.)

4086-349

Power Harness

2326-136

IFT-RC400 Remote Control

SRV2326-110

IFT-RF Module

2326-120

IFT-ACM Module

2326-150

IFT-ACM Cable

SRV2326-152

If any parts are missing or damaged, contact your Dealer before 

starting installation. 

DO NOT

 install a damaged  kit. Be sure to 

also reference the appliance Installers Guide.

Preliminary Preparation

Contents of kit:

Please note, while the SMART-WALL-B 

TV Kit, when in

-

stalled and used properly will allow most TVs to operate 

above the fireplace appliance without damaging the TV, 

operating a TV at the higher end of the manufacturer’s 

maximum  operating  temperature  range,  may  and  likely 

will have some impact on the life span of the TV appliance 

compared to operating it at normal ambient temperatures.   
The  SMART-WALL-B  uses  a  control  module  that  must 

be used with the IntelliFire™ Touch control system.  The 

SMART-WALL-B  blower  turns  on  and  operates  for  two 

minutes before the ignition sequence begins. The SMART-

WALL-B blower remains on for 20 minutes after the appli

-

ance is turned off to remove residual heat so the TV does 

not overheat.

NOTICE:  DO NOT

 

install a GFK-160A fan kit in a 

fireplace equipped with the SMART-WALL-B TV kit.  The 

GFK-160A fan could cause the TV to overheat.

Approvals

The flexible duct in this Smart-Wall™ (SMART-WALL-B)

TV kit is manufactured and marked to the requirements of 

UL-181, Class I air duct.

Introduction

The SMART-WALL-B TV kit conveys warm air from the 

appliance through an air duct to remote locations in the 

same room or other rooms of the building. See Figure 1.  

This kit is only approved for use with the following models:  

Hearth & Home Technologies does not guarantee that a 

user’s TV will safely operate long-term in conditions not 

strictly in compliance with those described in the previous 

paragraph.  

COSMO32-IFT

RAVE3012-IFT

JADE32IN

COSMO42-IFT

RAVE4013-IFT

JADE42IN

COSMO32-IFT-B RAVE32-IFT-B

JADE42IL

COSMO36-IFT-B RAVE36-IFT-B

JADE32IN-B

COSMO42-IFT-B RAVE42-IFT-B

JADE42IN-B
JADE42IL-B

  

TV installation must follow the guidelines in Figure 14 for 

the SMART-WALL-B to function properly.

NOTICE: 

 The Cold Climate feature of the IntelliFireTouch 

control system is not functional when the SMART-WALL-B 

kit is installed.

Summary of Contents for SMART WALL B

Page 1: ...aged contact your Dealer before starting installation DO NOT install a damaged kit Be sure to also reference the appliance Installers Guide Preliminary Preparation Contents of kit Please note while th...

Page 2: ...mum of two feet horizontally from TV unless register is mounted at least 12 inches above the TV Clearance from insulated flexible duct to combustibles 0 inches MODELS COSMO32 IFT COSMO42 IFT RAVE3012...

Page 3: ...e 2 Note A minimum clearance of 18 inches to any com bustible materials or combustible surfaces such as room furnishings furniture curtains etc is required from the fan housing air outlet Plan for thi...

Page 4: ...cal electric codes CAUTION Risk of shock Disconnect electrical power from fireplace power vent before performing any mainte nance repair or electrical wiring NOTICE Electrical service of 120 VAC 60Hz...

Page 5: ...ROL RF MODULE I S BRN ORANGE PILOT IFT RC400 REMOTE CONTROL GRN WHT BLK RED BLK IFT RC150 WIRELESS WALL SWITCH OPTIONAL SPLITTER BLK RED ADAPTER 6V DC BATTERY PACK BLK RED 6 PIN BLK RED GREEN MAIN RED...

Page 6: ...pproved options including lights and SMART WALL B To connect a light kit to the IFT ACM remove pro tective rubber cap labeled LIGHTS and connect to the female cord that was supplied in your lights kit...

Page 7: ...wire from the IFT ECM wire harness to the white wire coming from the SMART WALL B control module 13 Connect the male DC jack connector from the power harness 2326 136 to the female DC jack connector...

Page 8: ...T connect SMART WALL B module to IFT ACM Disconnect 6V power to lock out appliance Failure to follow instructions could result in damage to the TV WARNING BRN FLAME SENSE IGNITER TO JUNCTION BOX 110 1...

Page 9: ...LTM Control Module to IFT ECM wire harness brown wire 3 PIN FEMALE CONNECTOR Connect 3 Pin Female Connector from SMART WALLTM Control Module to IFT ACM AUX port ACCESSORY CABLE BRN BLK GREEN MAIN WHT...

Page 10: ...le the green LED on the IFT ECM is blinking tap anywhere on the gray indicator bar located at the top of the IFT RC400screen Taponthepairingfunctionasshownin Figure 13 If the IFT RC400 has been paired...

Page 11: ...e IFT RC400 IFT RC400 1 Touch screen on RC400 to wake up 2 Touch Turn Flame On 3 Observe touch screen if system is configured properly for SMART WALL B Operation a 2 minute countdown timer will be dis...

Page 12: ...ith an ambient temperature of not more than 75 degrees Fahrenheit 2 Since every home has unique air flow characteristics and maximum allowable operating temperatures can vary from manufacturer to manu...

Reviews: