background image

3

ANTENNA

LEARNING

BUTTON

SLIDE

SWITCH

OFF
REMOTE
ON

The remote receiver has a 3-position slide switch: OFF/
REMOTE/ON (see Figure 3).

Figure 3.  Remote Receiver

Choosing Remote Control or Thermostatic Opera-
tion (with a wall thermostat wired in series)

To operate appliance with a WALL THERMOSTAT only:

The slide switch on the remote receiver must be in
the ON position. To operate the system by remote
control again, return the slide switch on the remote
receiver to the REMOTE position and set the wall
thermostat ON or at a high-heat setting.

NOTE: The remote receiver will only respond to
the transmitter when the 3-position slide button on
the remote receiver is in the Remote position. If
the system does not respond to the transmitter on
initial use, see section Matching Security Codes.

1. With the slide switch in the ON position, the system

is on.

2. With the slide switch in the REMOTE position, the

system only operates if the remote receiver receives
commands from the transmitter.

3. With the slide switch in the OFF position, the system

is off.

NOTE:

 The slide switch should be placed in the OFF

position if you will be away from your home for an ex-
tended period of time. Placing the switch in the OFF
position also functions as a safety “lock out” by turning
the system off and rendering the remote receiver inop-
erative.

TRANSMITTER

Important: Before operating remote control, trans-
mitter and receiver must have matching security
codes. See section ‘Matching Security Codes’.

Important:

 Review Communication-Safety Features’

under ‘Transmitter Safety Features’ section. This safety
feature shuts down the fireplace system when a poten-
tially unsafe condition exists.

Important: 

Review ‘Auto Shutdown’ section. This

safety feature shuts down the fireplace after 9 hours of
continuous operation, in ON mode only.

Important:

 New or fully charged batteries are essen-

tial for proper operation of the multi-function transmit-
ter. The transmitter operates on 2 AAA-size 1.5V bat-
teries. Use Alkaline batteries for longer battery life and
maximum operational performance.

Insert 2 AAA-size 1.5V batteries into the battery com-
partment on the back of the transmitter. When the bat-
teries are correctly inserted, the screen will display
numbers (see Figure 4 for LCD Display Screen).

Figure 4.  Transmitter LCD Display Screen

1.

ROOM TEMP 

- Current room temperature.

2.

0

- Degrees Fahrenheit (

0

C indicates degrees Celsius).

3.

FLAME

 - Indicates burner/valve operational.

4.

LOW

 - Battery power low. Replace batteries within two weeks.

LCD DISPLAY SCREEN

TRANSMITTER

f i r e - p a r t s . c o m

Summary of Contents for RC-SMART-II

Page 1: ...IT NOT EXPRESSLY APPROVED BY THE PARTYRESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT NOTE This equipment has been tested and found to comply with the limits for a...

Page 2: ...ause damage to the gas valve or electronic module operating the gas appli ance and may also damage the remote receiver Wiring Millivolt Standing Pilot Valves Connect the remote receiver by connecting...

Page 3: ...me Placing the switch in the OFF position also functions as a safety lock out by turning the system off and rendering the remote receiver inop erative TRANSMITTER Important Before operating remote con...

Page 4: ...LCD screen see Figure 4 Location 2 3 Push the ON OFF button on the transmitter to change 0 F to 0 C 4 Push setting button on transmitter and Centigrade 0 C degree readings will display on LCD screen...

Page 5: ...stem When the transmitter is operating the fireplace it will continuously operate for 9 hours After 9 hours the fireplace will shut down To relight the fireplace 1 Press the ON OFF button The Auto Shu...

Page 6: ...by accident misuse abuse or installation error whether performed by a con tractor service company or owner is not covered by this warranty Seller will not be responsible for labor charges and or damag...

Page 7: ...THERMOSTAT WIRE ASSEMBLY JUMPER WIRE TO BROWN ORANGE GREEN VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S Figure 7 Standing Pilot Igni...

Page 8: ...ing Diagram IGNITION MODULE 3 VAC TRANSFORMER 3 VAC GRN ORG INTERMITTENT PILOT IGNITOR IGNITION MODULE 3V ON OFF WALL SWITCH LOW VOLTAGE PLUG IN 3V TRANSFORMER NEUTRAL HOT GROUND FLAME SPARKER SENSOR...

Page 9: ...PI Wiring Diagram Remote Control Wiring Diagrams PIEZO WHITE RED PILOT THERMOCOUPLE VALVE REMOTE RECEIVER VALVE GREEN ORANGE JUMPER WIRE TO BROWN PLUG IN TRANSFORMER 3 VAC BLACK RED GROUND TO FIREPLAC...