February 15, 2019
250-7690B
23
CASTILE INS
12
General Specifications
WATTS
Feed motor
6
Igniter
380
Convection blower
60
Exhaust
29
Total
475
AMPS
Feed motor
.05
Igniter
3.3
Convection blower
0.5
Exhaust blower
0.47
Total
3.87
VOLTS
Open circuit on high, medium, & low
115
VOLTS ON LOW FEED SETTING
Convection blower
84 V ( ± 1 V )
Exhaust blower
95 V ( ± 1 V )
VOLTS ON MEDIUM FEED SETTING
Convection blower
94 V ( ± 1 V )
Exhaust blower
105 V ( ± 1 V )
FEED MOTOR “ON” TIMES
Low
0.9 / sec
Medium
1.6 / sec
High
2.2 / sec
FEED MOTOR RPM
2
CONVECTION BLOWER CFM
160
EXHAUST BLOWER CFM
50
HOPPER CAPACITY
45 lbs
THERMOSTAT CIRCUIT VOLTS
24 VAC ( ± 5 V )
THERMOCOUPLE MILLIVOLTS
Green light
2.7 mV ( ± 0.5mV)
Red light
12.0 mV ( ± 1 mV)
POUNDS / HR BURN RATE
Low
1.5 lbs
Medium
2.5 lbs
High
3.5 lbs
SNAP DISCS
#1 (shuts off the convection blower)
110°F (43.33°C)
#2 (shuts off the feed system and the appliance in an over fire condition; auto reset)
250°F (121.11°C)
#3 (shuts off the appliance if a burn back occurs; manual reset)
250°F (121.11°C)
VACUUM
Water column on the high setting
0.08 to 0.10” W.C.
NOTE:
Appliance was plugged into a 120V outlet; voltage can vary depending on volts from the outlet.