4

D.  Power Outage

In the event of a power outage, the IFT-RC150 can 

continue to operate the hearth appliance if batteries are 

installed in the appliance’s battery backup system.  Refer 

to the appliance Owner’s Manual for instructions for 
operation during a power outage.

E.  Manual Appliance Shutoff

In the unlikely event that the IFT-RC150 malfunctions and 

will not turn off the appliance, call your dealer for service 

assistance. In the meantime, you may choose one of the 

following actions to turn off the appliance:

CAUTION!  Risk of burns!  Appliance surfaces are hot 

when operating and during cool down. Use care and wear 

gloves when opening the front and accessing compo-

nents inside the appliance.

Turn off power to the appliance (if back-up batteries 

are not installed):

•  If the appliance comes equipped with a wired-wall switch, 

use that to turn it off. 

  Alternately, you can also locate the house circuit breaker 

for appliance and turn it off.

NOTICE: Batteries should only be used as an appliance 

power source in the event of a power outage. Batteries 

should not be used as a primary long-term power source. 

A.  Turn Flame ON/OFF

•  To turn the flame ON, press the top of the rocker switch. 

•  To turn the flame OFF, press the bottom of the rocker 

switch.

The IFT-ECM on the appliance has a safety feature that 

automatically shuts down the appliance after 9 hours of 

continuous operation without receiving a command from 

any of its paired devices.  

Figure 6.  IFT-RC150 Functions

B. COLD CLIMATE

This function turns on a continuous pilot and keeps the air 

inside the hearth appliance warm while not in use. It is a 

useful feature in cold weather to minimize condensation 

on the appliance glass.
•  To turn the cold climate mode ON/OFF,  press the small 

momentary push button below the rocker switch.  

C.  LED INDICATOR

•  The LED indicator is located above the rocker switch.  It 

blinks every time it transmits a function and also during 

pairing.

• The LED also functions as a IFT-RC150 low battery 

indicator.  Replace batteries if the red LED blinks once 

every 3 seconds continuously for longer than 5 minutes.

Note:  

If the LED blinks once every 2 seconds for 2 minutes,  

          every 12 minutes, this indicates that the IFT-RC150  

       has lost communication with IFT-ECM.

3.  Operation

RED LED

COLD CLIMATE ON/OFF

FLAME ON

FLAME OFF

Summary of Contents for IntelliFire IFT-RC150

Page 1: ...nd or use of any component part not approved by Hearth Home Technologies Any such action may cause a fire hazard Read understand and follow these instructions for safe installation and operation B Determine Location Determine the location for the IFT RC150 The selected location should be in the same space as the gas appli ance with visual sight of the appliance The device must be placed within 30 ...

Page 2: ...3 2 On the IFT ECM move the ON OFF REMOTE switch to the REMOTE position The green LED will blink three times A few seconds later an audible beep will occur to indicate that the system is ready Note If the green LED continues to blink slowly system is searching for a clear channel wait until it stops before proceeding to step 3 3 Locate the pairing hole on the IFT ECM See Figure 4 Using a paper cli...

Page 3: ...GNITER ADAPTER I S 6 PIN 6V DC BATTERY PACK RED BLK BRN ORANGE PILOT GREEN MAIN BLK RED IFT RC150 WIRELESS WALL SWITCH RF MODULE ELECTRONIC CONTROL MODULE VALVE OPTIONAL WIRE ASSEMBLY MODULE RESET SWITCH APPLIANCE ON OFF CONTROL BRN BLK OPTIONAL ON SOME MODELS ONLY SPLITTER BLK RED F Wiring Diagram IntelliFire Touch System Wiring Diagram ...

Page 4: ...wer source in the event of a power outage Batteries should not be used as a primary long term power source A Turn Flame ON OFF To turn the flame ON press the top of the rocker switch To turn the flame OFF press the bottom of the rocker switch The IFT ECM on the appliance has a safety feature that automatically shuts down the appliance after 9 hours of continuous operation without receiving a comma...

Page 5: ...ve IFT ECM or RF module Manually turn OFF the appliance following steps listed under 3E and contact your dealer The IFT RC150 LED blinks randomly even though no command is given Communicating with IFT ECM This is normal operation The IFT RC150 com municates periodically with the IFT ECM to send or receive information The IFT RC150 LED blinks in a pattern of every 3 seconds continuously for longer ...

Page 6: ...wired wall switch IFT RC400 or IFT RC150 The wired wall switch is NOT available if a Power Vent is used 3 The Pilot button on the IFT ECM activates the Cold Climate function of the fireplace This function lights the pilot flame ONLY to provide enough heat in the firebox to reduce condensation in cool high humidity ambient conditions To activate the Cold Climate function press and hold the Pilot bu...

Page 7: ...or or no system ground Verify black gound wire in valve harness is connected to metal chassis of fireplace Pilot won t light there is no noise or spark 2 Red 1 Green Lockout Pilot solenoid not detected Check if valve harness orange wire is connected to pilot so lenoid valve Check pilot solenoid resistance nominal is 40 ohms If open or shorted replace valve Check valve harness wire continuity if op...

Page 8: ... Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black wire in 6 pin valve wire harness ...

Page 9: ...ever there is no guarantee that in terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation b...