Hearth & Home IntelliFire IFT-RC150 Installation Instructions Manual Download Page 2

Hearth & Home Technologies  •  RC150 IntelliFire

 Touch Installation Instructions  •  2326-980  •  9/16

2

Figure 3.  Mounting IFT-RC150 Wireless Wall Switch

Figure 4.  Pairing IFT-ECM and IFT-RC150

REMOTE POSITION

PAIRING HOLE

GREEN LED

PAIRING HOLE

5.  Secure the wall switch on a flat wall surface using the 

two screws and drywall anchors provided. See Figure 

3. 

6.  Insert the two AA batteries (supplied) in the correct 

orientation as marked in the battery receptacle. See 

Figure 3.  

Figure 2.  Wall Switch Disassembly

4.  Insert small flat screwdriver in the tab located in the 

bottom of the wall switch and twist the screwdriver to 

disassemble the wall switch.  See Figure 2.

E.  Pairing the IFT-RC150 to the Electronic Con-

trol Module (IFT-ECM)

CAUTION!  Risk of burns! DO NOT program the IFT  

Remote  Controls  to  the  IFT-ECM  when  flame  or  cold  

climate function is on or when appliance is hot.

1.  ON the IFT-RC150, remove the cover as shown in 

Figure 2 to access the pairing hole as shown in Figure 

3. 

2.  On the IFT-ECM, move the ON/OFF/REMOTE switch to 

the REMOTE position.  The green LED will blink three 

times.  A few seconds later, an audible “beep” will occur 

to indicate that the system is ready.  

 

Note:

  If the green LED continues to blink slowly (system 

is searching for a clear channel), wait until it stops before 

proceeding to step 3.

3.  Locate the pairing hole on the IFT-ECM.  See Figure 4.   

Using a paper clip or similar item, press and release 

the pairing button.  The IFT-ECM will “beep” once and 

a green LED will blink for 14 seconds.

  While the green LED on the IFT-ECM is blinking, press and 

release the pairing button on the IFT-RC150 with a paper 

clip or similar item.  The device will indicate it is in pairing 

mode by blinking red LED.  If the device has been paired 

successfully to the IFT-ECM, an audible double “beep” will 

be heard from the IFT-ECM.

4.  If pairing is unsuccessful, repeat step 3.
5.  Replace IFT-RC150 cover removed in step 1.

NOTICE:  To program both an IFT-RC400 and an IFT-

RC150 to an IFT-ECM, repeat the same steps separately 

for the IFT-RC400 and the IFT-RC150. Only one IFT-RC400 

remote control and one IFT-RC150 wireless wall switch can 

be programmed into an IFT-ECM. 

Summary of Contents for IntelliFire IFT-RC150

Page 1: ...nd or use of any component part not approved by Hearth Home Technologies Any such action may cause a fire hazard Read understand and follow these instructions for safe installation and operation B Determine Location Determine the location for the IFT RC150 The selected location should be in the same space as the gas appli ance with visual sight of the appliance The device must be placed within 30 ...

Page 2: ...3 2 On the IFT ECM move the ON OFF REMOTE switch to the REMOTE position The green LED will blink three times A few seconds later an audible beep will occur to indicate that the system is ready Note If the green LED continues to blink slowly system is searching for a clear channel wait until it stops before proceeding to step 3 3 Locate the pairing hole on the IFT ECM See Figure 4 Using a paper cli...

Page 3: ...GNITER ADAPTER I S 6 PIN 6V DC BATTERY PACK RED BLK BRN ORANGE PILOT GREEN MAIN BLK RED IFT RC150 WIRELESS WALL SWITCH RF MODULE ELECTRONIC CONTROL MODULE VALVE OPTIONAL WIRE ASSEMBLY MODULE RESET SWITCH APPLIANCE ON OFF CONTROL BRN BLK OPTIONAL ON SOME MODELS ONLY SPLITTER BLK RED F Wiring Diagram IntelliFire Touch System Wiring Diagram ...

Page 4: ...wer source in the event of a power outage Batteries should not be used as a primary long term power source A Turn Flame ON OFF To turn the flame ON press the top of the rocker switch To turn the flame OFF press the bottom of the rocker switch The IFT ECM on the appliance has a safety feature that automatically shuts down the appliance after 9 hours of continuous operation without receiving a comma...

Page 5: ...ve IFT ECM or RF module Manually turn OFF the appliance following steps listed under 3E and contact your dealer The IFT RC150 LED blinks randomly even though no command is given Communicating with IFT ECM This is normal operation The IFT RC150 com municates periodically with the IFT ECM to send or receive information The IFT RC150 LED blinks in a pattern of every 3 seconds continuously for longer ...

Page 6: ...wired wall switch IFT RC400 or IFT RC150 The wired wall switch is NOT available if a Power Vent is used 3 The Pilot button on the IFT ECM activates the Cold Climate function of the fireplace This function lights the pilot flame ONLY to provide enough heat in the firebox to reduce condensation in cool high humidity ambient conditions To activate the Cold Climate function press and hold the Pilot bu...

Page 7: ...or or no system ground Verify black gound wire in valve harness is connected to metal chassis of fireplace Pilot won t light there is no noise or spark 2 Red 1 Green Lockout Pilot solenoid not detected Check if valve harness orange wire is connected to pilot so lenoid valve Check pilot solenoid resistance nominal is 40 ohms If open or shorted replace valve Check valve harness wire continuity if op...

Page 8: ... Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black wire in 6 pin valve wire harness ...

Page 9: ...ever there is no guarantee that in terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation b...