19
June 18, 2019
7059-800B
HEATILATOR ECO-CHOICE PS50
Figure 19.1
Figure 19.2
6
Appliance Set-Up
A. Outside Air Kit
The Outside Air Kit that is available for purchase for this
appliance is 811-0872. This kit uses a 2 inch flex hose
(which is included in the kit) and uses hose clamps to
secure the hose.
Parts Included in 2 inch Kit 811-0872:
1 piece of 2 inch x 3 ft. flex hose, 2 hose clamps, 1 collar
assembly, 1 termination cap assembly, trim ring, 1 intake
air channel, fasteners (Discard the air intake channel, it is
not needed for this appliance.
Tools Needed:
Termination Cap
Hose Clamp
Trim Ring
2 inch flex hose
Hose Clamp
Collar Assembly
Air Intake Channel
(Discard)
Phillips Head screw driver; wire cutters; and hole saw or
jig saw.
1.
Measure distance from floor to air vent opening in
appliance and mark location on wall.
2.
Use a saw to cut opening in wall:
-
2 inch kit:
Cut a 2-1/2 to 3 inch opening on inside
wall and a 3 to 3-1/2 inch opening on outside of
house.
3.
Use wire tie or hose clamp depending on the Outside
Air Kit to secure flex pipe to collar assembly.
4.
Slide trim ring over flex pipe and run pipe through wall.
5. Attach flex pipe to outside termination cap with second
wire tie or hose clamp.
6. Secure termination cap to outside surface.
7.
Secure trim ring to interior wall.
Shock hazard.
•
Do NOT remove grounding prong
from plug.
•
Plug directly into properly grounded 3
prong receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front
of appliance.
CAUTION
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage