Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. D • 9/19
64
C. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as specified. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Combustible Mantels
Note: For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 10.A.
Figure 10.12
Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - ECHEL36IN-C,
ECHEL36STIN-C, ECHEL48IN-C and ECHEL48STIN-C
MEASUREMENT FROM
TOP EDGE OPENING
18
20
23
26
29
31
TO CEILING
9
12
6
3
1
Measurement from top edge opening
to bottom of appliance = 24-1/2 IN.
MAX.
Note:
All measurements in inches.
MEASUREMENT FROM
TOP EDGE OPENING
24
27
30
31
TO CEILING
9
6
3
Measurement from top edge opening
to bottom of appliance = 24-1/2 IN.
MAX.
Figure 10.13 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - ECHEL60IN-C and
ECHEL72IN-C
Note:
All measurements in inches.
TOP OF APPLIANCE OPENING
Figure 10.11 Location of Appliance Opening
If the Passive Heat kit will be installed, see Figure 10.18
for details regarding clearances to combustibles in addi
-
tion to the requirements for Combustible and Non-Com
-
bustible Mantel diagrams and the Mantel Leg/Wall Pro
-
jection diagrams (Figure 10.11-Figure 10.17).
Figure 10.14 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - Passive Heat Kit
Installed (All Sizes)
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
4
5
6
13-16
3
2
1
6
7
8
9
10
11
18
31
MAX.
MIN.
TO CEILING
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
Note:
All measurements in inches.