49
Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. D • 9/19
Accessories Requirements
• This appliance ships standard with a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
The junction box, control module, LED power supply
and wall switch receiver can be accessed by removing
the bottom glass shield and component heat shield. The
decorative barrier front must be removed to access these
components. See Figure 8.4.
B. Wiring Requirements
CAUTION! Risk of Overheating!
Component heat shield
MUST be installed before operating appliance. Electrical
components will be damaged.
CAUTION! Risk of Overheating!
DO NOT remove com-
ponent insulation from top of component heat shield.
Electrical components will be damaged.
NOTICE:
Batteries should only be used as a power
source in the event of an emergency power outage.
Batteries should not be used as a primary long-term power
source. Batteries tend to corrode over time. When using
batteries as a power source, the
6
volt transformer must
be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
IntelliFire™ Touch Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.4 IntelliFire
TM
Touch (IPI) Wiring
Diagram.
• This appliance is equipped with an IntelliFire™ control
valve which operates on a 6 volt system.