8
Hearth & Home Technologies • PH-FRT, PH-SIDE Instructions • 2600-970 Rev. H • 4/20
C
A
B
D
Figure 7 Passive Heat Minimum Framing Dimensions Open Top Discharge
OPEN TOP DISCHARGE MINIMUM FRAMING DIMENSIONS
A*
B
C
D
Minimum Height of
Discharge Opening
Clearance
to Framing
Width of Discharge
Opening
Minimum Clearance
Discharge Opening
to Ceiling
MEZZO36-C/ST-C
CRAVE4836-C/ST-C
ECHEL36IN-C/STIN-C
Inches
2
48
36-1/2
50
millimeters
51
1219
927
1270
MEZZO48-C/ST-C
CRAVE6048-C/ST-C
ECHEL48IN-C/STIN-C
Inches
2
48
48-1/2
50
millimeters
51
1219
1232
1270
MEZZO60-C/ST-C
CRAVE7260-C/ST-C
ECHEL60IN-C
Inches
2
48
60-1/2
50
millimeters
51
1219
1537
1270
MEZZO72-C/ST-C
CRAVE8472-C/ST-C
ECHEL72IN-C
Inches
2
67-1/2
72-1/2
69-1/2
millimeters
51
1715
1842
1765
*
Wire mesh required for front discharge or open top discharge passive heat installations with discharge
opening of 3 inches or greater.
Framing Dimensions - Passive Heat Open Top Discharge Single-Sided or See-Through
WARNING! Risk of Fire!
Wire mesh required on bottom of discharge opening when discharge
opening is greater than 3 inches. Secure mesh to top of framing.
Open Top Discharge: Both sides and the top are open allowing air to be conveyed into the room.